# CMU Researchers Use pi0.5’s Activations to Flag Robot Failures

Published 2026-10-24 · Robotics.world Team · Robotics.world

> A new paper describes Progress Probes, a monitor that uses a robot policy’s internal activations to estimate task progress and flag deviations. Tests in simulation and on a physical robot report strong failure-detection results, though performance varies by task.

> “Our method trains linear probes on policy activations from demonstrations to estimate progress, then flags executions that deviate from expected progress.”
>
> Atiksh Bhardwaj and co-authors, the paper’s authors

Researchers from Carnegie Mellon University and Cornell University posted the paper on October 22, 2026, proposing a monitor that reads a robot policy’s internal signals instead of asking a separate vision-language model to judge whether a task is going wrong. Their method, called Progress Probes (P²), uses a simple linear readout to estimate task progress from activations already generated during the policy’s operation.

The experiments use [Physical Intelligence](https://robotics.world/companies/physical-intelligence)’s open pi0.5 vision-language-action model. Across six simulated tasks and six real-world manipulation tasks, the authors report state-level AUROC scores of 0.788 and 0.78, respectively. The monitor is trained using successful demonstrations rather than failure examples, and compares estimated progress with the expected pace of successful executions.

## Progress becomes a signal inside pi0.5

The team trains its probe on successful demonstrations. For each point in a demonstration, it assigns a progress label based on the fraction of the trajectory remaining, then fits a linear mapping from the model’s internal activation to that label. At runtime, the monitor compares its estimate with the progress expected at that time, based on the average duration of successful demonstrations.

If the estimated progress falls behind that nominal pace, the monitor can raise an alarm. The probe runs on activations pi0.5 has already calculated, so it adds little computation, and its training does not require labeled failure data. The system does not penalize runs that move faster than the expected pace.

## Six physical tasks test the alarm

For the hardware evaluation, the researchers used a Franka Research 3 arm with a DROID camera setup. Their six tasks included stacking blocks, placing a knife in a bowl, moving a candy bag without spilling its contents, and pouring coffee beans into a bowl. The team evaluated 120 robot rollouts—20 per task, split evenly between successful and failed runs—and manually marked where failures began.

Across those tasks, P² reached an average state-level AUROC of 0.78, a measure of how well a monitor separates successful states from failed ones. The reported score was 0.92 for the candy-bag task and 0.87 for block stacking, but 0.26 for pouring coffee beans. The authors suggest that the coffee-bean failures can be visually subtle and arise despite actions that otherwise look familiar.

## The simulation benchmark shows the speed trade-off

In simulation, the monitor achieved a state-level AUROC of 0.788 and an episode-level AUROC of 0.909 across six VLABench tasks. The evaluation used 600 rollouts, evenly divided between successful and failed executions. At a threshold calibrated for a 5% false-positive rate, the detector’s true-positive rate reached 0.54 at three-quarters of an episode and 0.64 at its end; on average it flagged a failure after 0.60 of the episode.

On an NVIDIA RTX A6000, the authors measured P²’s monitoring latency at 0.026 milliseconds. They report that it can run between five and 20,000 times faster than external foundation-model monitors, depending on the comparison. The paper also compares P² with Robometer, a 4-billion-parameter model, and reports comparable failure-discrimination performance against its fine-tuned version.

## A timing alarm is not a universal failure detector

The method’s simplicity also defines its limits. Its progress labels come from normalized time remaining in successful runs, so unusual but valid pauses or changes in task pace [may](https://robotics.world/companies/may-mobility) complicate the comparison. The design treats falling behind, rather than moving faster, as the warning signal. The uneven coffee-bean result shows that a strong average does not guarantee a useful signal for every manipulation task.

The study tests only pi0.5 and mainly probes activations from its vision-language backbone. The authors identify transfer to other VLA families, including NVIDIA’s GR00T and MolmoAct, as future work, along with examining whether internal activations from continuous action experts could provide additional signals. The results show that a policy’s existing computation can supply a progress alarm, but do not establish that one probe will catch every physical failure.

## Sources

1. Original source · Preprint [arXiv](https://arxiv.org/html/2610.31613v1) arXiv:2610.31613

## Related stories

- [ThinkWorld Trains Robot Policies by Scoring Imagined Futures](https://robotics.world/news/thinkworld-trains-robot-policies-imagined-futures)
- [RoboColosseum Tests Robot Policies in 5,699 Comparisons at 124 Sites](https://robotics.world/news/robocolosseum-robot-policies-124-sites)
- [ActPrune Uses Predicted Robot Motion to Prune VLA Tokens](https://robotics.world/news/actprune-predicted-robot-motion-prunes-vla-tokens)
- [VICTR Preprint Reports 23.8% Success on Unseen Out-of-Domain Real-World Robot Tasks](https://robotics.world/news/victr-raises-vla-success-unseen-tasks)
- [Berkeley Researchers Report Feasibility Guarantees for Robot Teams](https://robotics.world/news/berkeley-researchers-feasibility-guarantees-robot-teams)

## Explore

[More articles](https://robotics.world/news)

---

Canonical: https://robotics.world/news/cmu-progress-probes-pi05-robot-failure-monitoring