# Aero Hand Open: A Simulation-Ready Tendon-Driven Hand for Dexterous Manipulation Learning

Robotics.world

> Tendon-driven hands are cheap and human-like because their motors sit away from the joints and one motor can pull several joints at once. That same design makes them hard to learn on: the coupled…

**arXiv**: 2608.28578 · Preprint · not peer-reviewed

**Published**: 2026-08-28 · revised · 2026-09-23

**Authors**: Nan Wang, Mohit Yadav, Jonathan Wulff, Aidan Rosenbaum, Kezhou Chen, Yuvan Sharma, Xu Dong, Yiwei Tao

## In plain words

Tendon-driven hands are cheap and human-like because their motors sit away from the joints and one motor can pull several joints at once. That same design makes them hard to learn on: the coupled, underactuated transmission is difficult to put into a simulator, and the joints a single cable drives cannot be commanded independently.

## AI summary

## Overview

**Research area:** Robotics — dexterous manipulation hardware, tendon-driven (underactuated) hand design, and simulation-to-reality transfer for reinforcement learning.

**Technical level:** Advanced. The paper assumes familiarity with robot kinematics, MuJoCo tendon modelling, system identification, and sim-to-real policy training.

**Scope (one sentence):** The paper presents Aero Hand Open, a 374 g, seven-motor, sixteen-joint 3D-printed tendon-driven hand whose cable transmission is modelled directly in MuJoCo and paired with an identified actuation map, so that a manipulation policy can be trained entirely in simulation and deployed with no fine-tuning and no state estimation.

## What This Paper Is About

Tendon-driven hands are cheap and human-like because their motors sit away from the joints and one motor can pull several joints at once. That same design makes them hard to learn on: the coupled, underactuated transmission is difficult to put into a simulator, and the joints a single cable drives cannot be commanded independently. This paper's goal is to close that gap for one specific low-cost hand by shipping a simulation model that reproduces the cable routing itself, an identified mapping between simulation commands and motor commands, and a complete reinforcement learning and deployment package.

## Key Contributions

1. **An open, capable, repairable hand.** Aero Hand Open is a five-finger, sixteen-joint, seven-motor tendon-driven hand with a mass of 374 g and a bill of materials of $314 (198 × 95 × 53.5 mm). It performs all 33 grasp types of the GRASP taxonomy with a single hardware configuration and no hardware change between grasps. Mechanical design, firmware and control stack are released, and every structural part is 3D printed so damaged parts are reprinted rather than reordered.
2. **A tendon-level simulation model.** The full cable transmission is modelled in MuJoCo (released through MuJoCo Menagerie) with 16 hinge joints, 20 spatial tendons and 7 actuators. Every actuation cable, coupling cable and return spring is routed over wrapping cylinders whose positions and radii come from the CAD model, so moment arms follow from geometry rather than being tuned.
3. **An identified actuation map, validated in both directions.** The sim-to-real interface is expressed as a chain of linear or affine maps, `d = A q` with `A ∈ ℝ^{7×16}` of rank seven, including the thumb's three-way coupling. It is checked channel by channel, kinematically (cable excursion from open hand to fist) and dynamically. Combined with domain randomisation, this is what the authors say enables transfer without fine-tuning.
4. **A reinforcement learning package.** The training environment, reward and randomisation settings, and the deployment node are released, with observation and action spaces restricted to hardware-available signals (the seven motor encoders only). The pipeline is demonstrated on in-hand cube rotation.

## Main Findings

- **Underactuation is by construction, not by choice.** Seven motors are what the budget and the volume behind the palm allow, so sixteen joints are driven from seven actuators; the only proprioception is the seven motor encoders (16-bit positions over the serial bus).
- **Staged finger closure comes from graded springs.** One cable drives MCP, PIP and DIP. The MCP return spring is deliberately softer, so the finger first closes at its base until the MCP reaches its 1.57 rad (90°) limit, after which the stiffer distal springs give way and the coupled PIP and DIP curl. Spring specifications used in the model are 352 N/m with 11.376 mm rest length at the MCP, 4000 N/m with 21.336 mm at the distal joints, and 1897 N/m with 13 mm for the thumb CMC spring.
- **The thumb is the coupled case.** CMC abduction is driven directly through a short linkage over 0–100° (1.75 rad); the CMC flexion cable flexes the thumb by about 55°, and the flexor cable curls MCP and IP by a further 90°. Because two cables cross the abduction axis, the three flexion channels are mutually coupled, with the CMC term entering the two cable channels with opposite signs.
- **Winding coefficients come from CAD, not fitting.** The MCP coefficient is 19.62 mm of take-up over 90° divided by π/2, giving 12.49 mm/rad; the finger coefficients are (12.49, 7.32, 9.00) mm/rad. Thumb coefficients of 2.50 mm/rad are fixed by the pulley radius directly, since a cable wrapping a pulley of radius r through angle θ takes up rθ.
- **One genuinely negative entry, and it matters for control.** The flexor channel pays cable out as the CMC joint flexes (2.50 × 0.960 = −2.40 mm at 55°, i.e. −15.28° of shaft rotation). Its calibrated lower limit is therefore not zero; a controller that clamped that channel at zero would block full CMC flexion. The value the hand is commanded against agrees with the model to 1.1 × 10⁻³ degrees, and enumerating the 2^16 vertices of the joint box reproduces the thumb limits to better than 10⁻³ degrees and the finger limits to 3.7 × 10⁻² degrees.
- **Command quantisation is negligible.** The finger excursion of 288.16° over 65535 counts is 0.69 μm of cable per count, two to three orders of magnitude below the tracking residuals of the transmission.
- **The three estimates of finger excursion disagree, and the map absorbs it.** The hand travels 44.45 mm of cable from open to fist, the linear map gives 45.26 mm, and simulated sweeps give 45.72–46.21 mm across the four fingers; anchoring the affine map at its endpoints leaves a gain of 1.0–2.1% on the simulation side.
- **Thumb identification is first order and that is measured, not assumed.** A bilinear map in the two cable lengths attains R² ≥ 0.9995 on the sweeps, and adding quadratic terms does not improve it. Cited limitation: the first-order model cannot represent the saturation at the extended end of the MCP joint, where the ten CMC-flexion levels converge (spread 2 × 10⁻⁴ rad there versus about 8 × 10⁻² rad over the rest of the sweep).
- **The simulator under-represents abduction-to-flexion coupling.** The fitted abduction column stays below 5 × 10⁻³ rad/rad, so the whole 1.75 rad abduction range moves the flexion joints by less than 0.01 rad, whereas the CAD-derived map asserts 2.50 mm of cable per radian. The mapping therefore removes that term from the fit reference and adds it back analytically at run time — compensating in software for a coupling the simulator does not reproduce.
- **Kinematic validation of the four finger channels:** the hardware and model cable excursions agree to 0.04, 0.32, 1.40 and 0.41 mm; the largest is 3.1% of a 44.45 mm excursion and the others are below 1%. The abduction joint reaches 1.746 rad in the portion of the validation reported in the supplied text.
- **Durability and repeatability.** The transmission survives more than 400,000 full-actuation cycles without cable failure or loss of range, which at 1.2 Hz corresponds to over 90 h of continuous articulation. The hand returns to within 3 mm of cable excursion across repeated closures, inside the 44.45 mm finger stroke. Cable tension is of order 100 N for roughly 12 N fingertip force, against a worst-case actuator tension of about 66 N (0.59 N·m stall torque on the 9.0 mm spool) and a braided Kevlar/Vectran cable strength of 69 kg, about 680 N.
- **Published results that are not in the supplied text:** the quantitative outcomes of the in-hand cube rotation experiment, the dynamic validation results, and the conclusion are cut off in the provided content, so no success rates or transfer numbers are reported here.

## Methodology in Plain English

The authors built the hand first and let the learning requirement shape the design: keep the transmission simple enough to reproduce faithfully, keep sensing honest by exposing only the seven motor encoders, and keep the structure entirely printable.

For simulation, instead of approximating each joint with a simple position motor, they modelled the cables themselves as MuJoCo spatial tendons. Each finger carries four: an actuation cable from a palm anchor over three wrapping cylinders to the distal phalanx, a coupling cable tying PIP to DIP, and two extension springs. The wrapping cylinders are placed at the physical pulley locations taken from CAD, and the solver is explicitly told which side of each pulley a cable passes on — otherwise it could route a cable the wrong way and flip the sign of its moment arm. The thumb's two cables cross the abduction axis over a pulley cluster on the CMC base link.

For the interface, they treat the cable take-up as a linear function of joint angles, with coefficients read off the CAD model by sweeping one joint at a time and measuring the change in routed cable path length. The thumb rows share columns because the two cables cross the same axes. Motor shaft rotation follows by dividing by the 9.0 mm spool radius, and the 16-bit command follows by normalising each channel over its achievable excursion — computed as the extrema of the linear map over the box of admissible joint angles, which is why one channel legitimately goes negative.

The mapping between simulator tendon length and motor command is affine on the four finger channels, anchored at the endpoints of each interval. The thumb cannot use that shortcut, so they drive the simulated thumb over its workspace, log cable lengths, abduction angle and joint angles, and fit a small linear regression from those inputs to the three flexion angles; the inverse direction uses a separate pair of first-order fits per cable because the forward regression is not invertible. Finally, they check the whole chain against the hardware: comparing independent estimates of cable excursion at the two end stops, testing each channel, and checking repeatability and durability on the physical hand.

## Why This Matters

**Impact on research.** The paper argues that for tendon-driven hands the decisive modelling step is at the actuator/transmission level rather than the joint level — the same lesson drawn from actuator-level modelling in legged locomotion. By releasing the model, the identified map, and the training stack together, it gives other groups a concrete template for making an underactuated, encoder-only hand learnable, and a cheap baseline against a comparison table of platforms ranging from the InMoov to the Shadow Hand.

**Real-world applications.**

- Affordable research and teaching platforms for dexterous manipulation, at a $314 bill of materials and 374 g.
- Field-repairable end effectors, where a worn phalanx is reprinted in about 45 min rather than reordered — relevant where supply chains are slow.
- Grasp-diverse tasks that need thumb opposition across all 33 GRASP taxonomy grasp types with one hardware configuration.
- Learning pipelines for hardware that has no joint encoders and no tactile sensing, where only motor-side signals are available at run time.

**Industry relevance.** The release of firmware, deployment node and a MuJoCo Menagerie model matters for teams that need to train in parallel simulation and deploy without a per-robot calibration campaign. The durability numbers — over 400,000 cycles, more than 90 h at 1.2 Hz — speak directly to whether cable wear is a practical limit for a training-and-deployment campaign; the authors argue it is not.

## Future Directions

- **Close the simulator's abduction-to-flexion gap.** The mapping currently compensates in software for 2.50 mm/rad of coupling that the simulated thumb does not reproduce; representing that coupling in the model would remove the workaround and let the interface stay purely affine.
- **Represent saturation.** The first-order thumb model cannot express the convergence of the ten CMC-flexion levels at the extended end of the MCP joint (2 × 10⁻⁴ rad versus about 8 × 10⁻² rad elsewhere); a piecewise or higher-order model at the limits is an open question.
- **Add sensing within the design commitment.** The hand deliberately exposes only motor encoders; whether adding joint or tactile sensing pays for itself in policy performance, as it does for platforms like ORCA, is untested here.
- **Broaden the learning demonstration.** The pipeline is shown on in-hand cube rotation with seven motors driving sixteen joints; extending it to the full 33-grasp repertoire and to tasks requiring independent finger command is the natural next test of how far underactuation can be pushed.

## Target Audience

Robotics researchers and engineers working on dexterous manipulation hardware, tendon-driven transmission design, and sim-to-real reinforcement learning. It is most useful to readers who already understand rigid-body simulation and want a concrete, fully released example of modelling a cable transmission accurately enough to train on — and to builders who want a documented, low-cost hand they can print, repair and train policies for. Readers looking for policy-learning results or benchmarking comparisons should note that the learning outcomes are not quantified in the available text.

## Authors’ abstract

Tendon-driven hands are anthropomorphic, and moving the actuators off the joints is what makes a hand of this capability affordable to build. Two effects produce that saving. Routing force through a cable removes the requirement that a motor fit inside the joint it drives, so smaller and cheaper motors suffice, and one motor can drive several joints through a single cable, so fewer motors are needed. They are also harder to learn on than a direct-drive hand. The…

[The full abstract on arXiv](https://arxiv.org/abs/2608.28578)

[Read the original paper](https://arxiv.org/abs/2608.28578)

## Related papers

- [GE-Act 2.0: Pretraining and Scaling a World-Action Model for Robotic Manipulation](https://robotics.world/paper/ge-act-2-0-pretraining-and-scaling-a-world-action-model-for-robotic-2609.05588) 2026-09-04 · cs.RO · Also by Nan Wang
- [Dex-X: Learning Visual-Tactile Dexterous Manipulation From Human Videos with Simulated Interaction](https://robotics.world/paper/dex-x-learning-visual-tactile-dexterous-manipulation-from-human-videos-2609.07747) 2026-09-07 · cs.RO · Key terms of the title in common
- [Bench2Dex: Benchmarking Visuo-Tactile Bimanual Dexterous Manipulation Across Dexterous Hands](https://robotics.world/paper/bench2dex-benchmarking-visuo-tactile-bimanual-dexterous-manipulation-2609.15726) 2026-09-14 · cs.RO · Key terms of the title in common
- [WorldLine: Action-Driven Visual Simulation for Robotic Manipulation](https://robotics.world/paper/worldline-action-driven-visual-simulation-for-robotic-manipulation-2609.38059) 2026-09-29 · cs.RO · Key terms of the title in common
- [ALFRED: Requirement-driven development of an open-source mobile manipulator for long-term plant monitoring](https://robotics.world/paper/alfred-requirement-driven-development-of-an-open-source-mobile-2610.01477) 2026-10-01 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/aero-hand-open-a-simulation-ready-tendon-driven-hand-for-dexterous-2608.28578