An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

Bioprinting can fabricate tissue constructs, but the field lacks a robust, automated, quantitative way to measure the thickness of printed constructs, especially when their shapes are complex.

The paper’s first page · arXiv:2609.12206
arXiv
2609.12206 · accepted · IROS
Published
2026-09-10
Authors
Ehsan Zobeidi, Omid Rezayof, Farshid Alambeigi

In plain words

Bioprinting can fabricate tissue constructs, but the field lacks a robust, automated, quantitative way to measure the thickness of printed constructs, especially when their shapes are complex. Prior thickness-measurement methods either require manual input or assume simple geometries such as straight lines or curves that do not loop back on themselves.

AI summary

Overview

Research area: Medical robotics, computer vision, and bioprinting/tissue engineering.

Technical level: Intermediate. The segmentation pipeline is conceptually accessible, while the thickness calculation relies on 3D geometry, point clouds, and ray casting.

Scope: This paper presents and validates a fully automated pipeline that segments bioprinted constructs in RGB images and measures their thickness from structured-light point clouds along the robot’s deposition path.

What This Paper Is About

Bioprinting can fabricate tissue constructs, but the field lacks a robust, automated, quantitative way to measure the thickness of printed constructs, especially when their shapes are complex. Prior thickness-measurement methods either require manual input or assume simple geometries such as straight lines or curves that do not loop back on themselves. The paper’s goal is to measure thickness automatically for arbitrary printed geometries using an RGB image, a 3D point cloud, and the robot’s recorded deposition path.

Key Contributions

  1. A fully automatic segmentation pipeline for bioprinted constructs. The method uses the Canny edge detector to find boundary pixels, generates “raw” contours that lie accurately on boundaries but often fail to enclose regions, generates “rough” contours by filling and dilating the raw contours, and fuses the two into precise closed contours. No user input is required, unlike prior GrabCut-based approaches.

  2. A geometry-driven thickness-measurement algorithm that handles complex shapes. The method combines the segmentation mask, the point cloud, and the robot’s recorded needle path to compute thickness along the deposition trajectory. It supports spirals, looped structures, and disconnected constructs, avoiding the straight-line and single-valued-curve restrictions of earlier work.

  3. A computationally efficient formulation suitable for future closed-loop use. The authors position the method as fast enough to eventually support real-time modulation of printing parameters, and they report processing times in simulation rather than relying on slow optimization-based segmentation.

  4. Validation in both simulation and hardware. The pipeline is tested on eight simulated spiral cases with known ground-truth thickness and on four physical constructs printed with a robotic bioprinting setup.

Main Findings

  • Simulation accuracy: Across eight simulation cases, the mean absolute error ranged from 0.025 mm to 0.057 mm at a spatial resolution of 0.1 mm × 0.1 mm per pixel. All mean absolute errors were below 0.06 mm (60 µm), with an average of 41 µm reported in the discussion.

  • Worst simulation case: Case 4, a Fermat spiral with 2 mm uniform thickness and no gaps, had the highest average error at 0.057 mm, with a maximum error of 0.135 mm. Across all cases, the largest maximum error was 150 µm, which the paper describes as approximately the size of one pixel and attributes mainly to discretization.

  • Resolution trade-off: In the resolution study, processing time increased roughly linearly with the number of pixels, while accuracy degraded rapidly as resolution decreased. The study varied image size as ⌊512r⌋ × ⌊512r⌋ for ten ratios from r = 1/4 to r = 2, with pixel size 0.1/r mm × 0.1/r mm and a fixed 2 mm thickness.

  • Accuracy is largely independent of thickness: In the thickness study, which varied thickness from 0.4 mm to 4 mm, accuracy remained largely independent of thickness. Total processing time increased from approximately 70 ms at 0.5 mm thickness to approximately 90 ms at 4.0 mm thickness, which the authors attribute to thicker constructs covering more pixels and producing more detailed boundary polygons.

  • Hardware results: Four patterns were printed: a straight line, a Fermat spiral, an Archimedean spiral, and an Archimedean spiral with gaps. The straight-line case had an average measured thickness of 2.135 mm with standard deviation 1.280 mm and quartiles Q1 = 0.917 mm, Q2 = 2.790 mm, Q3 = 3.322 mm. The Fermat case averaged 1.569 mm with standard deviation 0.289 mm; the Archimedean case averaged 1.604 mm with standard deviation 0.330 mm; the Archimedean-with-gaps case averaged 1.575 mm with standard deviation 0.411 mm.

  • Variability in the straight-line case: The paper explains the higher standard deviation of 1.280 mm in the line case by the fact that the injection rate was turned off halfway through the print, so thickness was decaying along the remaining path. The Fermat and Archimedean spirals showed lower standard deviations, averaging 0.34 mm, indicating more uniform thickness.

  • No experimental ground truth: The hardware experiments do not report ground-truth thickness values. The paper reports means, standard deviations, and quartiles over the print length instead.

Methodology in Plain English

The robot first prints a construct and records the needle path. A structured-light 3D camera then captures an RGB image and a point cloud of the printed material on a background.

To isolate the printed material, the method detects edges in the RGB image with the Canny detector. These edge-based “raw” contours sit accurately on the true boundary, but they often fail to close around a region and can trace back on themselves or split one region into several fragments. To recover complete regions, the method fills the raw contours, dilates the filled shapes to close gaps, and detects contours again, producing “rough” contours. Rough contours enclose whole regions but have imprecise boundaries.

The fusion step assigns each raw contour to a rough contour when more than half of its vertices fall inside the rough region. For each rough-contour vertex, the closest raw-contour vertex becomes an anchor point. Consecutive anchors on the same raw contour are connected by inserting the intermediate raw vertices in the correct cyclic order, unless the index difference exceeds a Jump Threshold, in which case the anchors are connected directly. The result is a precise closed contour that both follows the true boundary and separates the construct from the background.

For thickness, the method fits a plane to all contour vertices and projects the contours and path points onto that plane. A ray-casting test identifies which contour contains each projected path point; if none contains it, thickness at that point is zero. For a path point, the local tangent is approximated from its neighboring path points. A plane through the path point and perpendicular to this tangent is intersected with the containing contour, and the nearest intersection on each side of the path point is selected. Left and right sides are separated using the sign of a cross-product test with the fitted plane normal. Thickness is the Euclidean distance between the two side points. Repeating this along the path produces a thickness profile.

In the hardware setup, the system used a 7 degree-of-freedom KUKA LBR Med 7 robot, a Zivid Two M70 structured-light 3D camera with a manufacturer-reported point cloud resolution of approximately 0.2 mm, and a custom extruder with a linear actuator, Arduino controller, 50 ml syringe, and 18-gauge needle. Blue-dyed ultrasound gel (Aquasonic 100) was used as the printing material. The robot moved at a constant 3 mm/s. The straight-line case used an injection rate of 0.144 mm/s at the start and 0 from halfway onward; the spiral cases used a constant 0.027 mm/s. All studies used Jump Threshold = 10, and the hardware experiments used a 3 × 3 dilation kernel.

Why This Matters

The paper addresses a measurement gap in bioprinting: printing hardware has advanced faster than the ability to quantitatively inspect what was printed. By turning camera data and robot path data into a thickness profile, the method gives researchers a way to compare printed geometry against intended geometry and to tune parameters such as deposition rate and robot velocity.

  • Volumetric muscle loss and skeletal muscle repair: The introduction motivates the work with large skeletal muscle injuries that exceed the tissue’s natural repair capacity, where bioprinting is being explored as an alternative to surgical grafting.

  • In situ bioprinting: Direct deposition into a defect site could benefit from automated, on-the-spot inspection of printed thickness and uniformity.

  • Tissue-model fabrication and drug testing: Uniform, well-characterized constructs are useful wherever printed tissue models need reproducible geometry.

  • Quality control in biofabrication: The method provides a quantitative inspection step that could be integrated into robotic bioprinting workflows rather than relying on visual comparison of RGB images.

Industry relevance: The approach is relevant to companies building robotic bioprinters, structured-light inspection systems, and automated manufacturing equipment for tissue-engineering products. Its use of a commercial robot, commercial camera, and open-source vision tools makes the pipeline relatively easy to adapt to existing robot-cell architectures.

Future Directions

  • Closed-loop bioprinting: The authors plan to integrate the framework into closed-loop procedures where on-demand feedback dynamically modulates deposition rate and robot velocity during printing.

  • Multi-layer and multi-material printing: The conclusion names multi-layer, multi-material bioprinting as a future target, which would require extending thickness evaluation beyond a single deposited layer.

  • Relaxing the flat-plane assumption: The current thickness calculation assumes printing occurs on a flat deposition plane and fits a plane to the contours. Curved or irregular deposition surfaces remain an open case.

  • Independent ground-truth validation and biological materials: The hardware studies report no ground-truth thickness and use a gel rather than a cell-laden bioink. Comparing measurements against an independent metrology method and testing with biological materials would strengthen the evidence beyond the simulation studies.

Target Audience

This paper is most useful to robotics and computer vision researchers working on medical or manufacturing automation, bioprinting and tissue-engineering laboratories that need quantitative print inspection, engineers developing quality-control systems for biofabrication, and graduate students interested in combining point-cloud processing with robot motion data. Readers seeking biological outcomes or cell-maturation results will not find them here; the contribution is measurement technology.

Authors’ abstract

Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging…