ARCGym: Benchmarking Deep Reinforcement Learning in Autonomous Robotic Colonoscopy

Simulators used to train learning-based colonoscopy navigation almost exclusively model fully actuated capsule robots, which do not capture the contact-rich behavior of a long, flexible clinical…

The paper’s first page · arXiv:2609.22803
arXiv
2609.22803
Published
2026-09-19
Authors
Guanglin Ji, Martina Finocchiaro, Kenny Erleben, Hang Yin

In plain words

Simulators used to train learning-based colonoscopy navigation almost exclusively model fully actuated capsule robots, which do not capture the contact-rich behavior of a long, flexible clinical colonoscope whose tip may not move when the shaft is pushed.

AI summary

Overview

Research area: Surgical robotics and reinforcement learning (RL), specifically simulation benchmarks for autonomous flexible endoscopic navigation in colonoscopy. Technical level: Intermediate. The RL setup and evaluation protocol are accessible to anyone familiar with basic RL concepts; the soft-tissue finite-element modeling and reward equations are more advanced. Scope (one sentence): The paper introduces ARCGym, an open-source Isaac Lab / Isaac Sim benchmark for image-based RL navigation of flexible colonoscopes through five CT-derived deformable colon anatomies, with standardized subtasks, unified success metrics, and baseline results for four RL algorithms.

What This Paper Is About

Simulators used to train learning-based colonoscopy navigation almost exclusively model fully actuated capsule robots, which do not capture the contact-rich behavior of a long, flexible clinical colonoscope whose tip may not move when the shaft is pushed. The authors build a reproducible, open benchmark in which several robot types navigate deformable colons reconstructed from real patient CT scans, with tasks and metrics defined so that different methods can be compared fairly. The paper's goal is to establish baselines and to show where learning-based navigation currently breaks down.

Key Contributions

  1. An open-source RL framework for colonoscopy navigation. ARCGym provides five clinically derived colon anatomies segmented from CT colonography (CTC) images in the HQColon dataset, modeled as deformable bodies, together with anatomically defined navigation subtasks and standardized success metrics. Code is released at https://github.com/bentferrari/IRE_ARCGym.
  2. Multiple robot types under one interface. A 6-DoF capsule robot, a magnetically driven distal-end actuated flexible endoscope, and a conventional proximal-insertion flexible endoscope all share unified observation and action interfaces, enabling cross-platform comparison.
  3. A composite reward for occlusion-robust learning. The reward combines a depth-based lumen-centering term with a lumen-visibility score, and the paper ablates six reward variants to show the effect of each component and of constrained PPO.
  4. Baseline and generalization evaluations. Four RL algorithms are compared across four tasks, and the best policy is tested on unseen colons, under perturbed material parameters, and under different anchor-point densities.

Main Findings

  • On-policy methods dominate; SAC fails entirely. With the magnetic-driven endoscope, constrained PPO reaches 100.0% (Task 1), 30.0% (Task 2), 90.0% (Task 3) and 80.0% (Task 4) success. PPO reaches 20.0 / 0.0 / 40.0 / 0.0, A2C 20.0 / 0.0 / 20.0 / 0.0, and SAC 0.0 on all tasks.
  • Task 2 (sigmoid) and Task 4 (splenic flexure) are the hard cases. In the learning curves, Task 4 shows the lowest reward and slowest improvement, while Task 3 (descending colon) is easiest because of its long, relatively straight lumen.
  • Proximal insertion remains unsolved. The proximal-insertion endoscope learns only limited behavior: Task 1 improves moderately and reaches a non-zero lumen alignment rate, but Tasks 2, 3 and 4 do not converge, and the proximal-insertion column reports 0.0% success for every algorithm. Manual teleoperation does complete the same navigation in the same environment, indicating the simulator is physically navigable and that the failure is in the learning, not the physics.
  • Rigid simulation does not transfer to deformable anatomy. A constrained PPO policy trained in a rigid colon and deployed unchanged to the matched deformable colon scored 0 success, 2.36% mean normalized progress and a 100% timeout rate on Task 2, despite a center-alignment score of s_c = 0.707.
  • The full reward with constraints is the most consistent. In the reward ablation on Colon 1 and Colon 2, constrained PPO with the full reward achieves mean center-alignment scores of 0.882, 0.898, 0.919 and 0.814 for Tasks 1–4. Single-component rewards are inconsistent: the s_c-only reward degrades on Task 4, s_1 and s_o help Task 3 but not the hardest case, and s_2 is strongest on Task 4 but weaker on Task 3.
  • Policies tolerate material changes but not anchor changes. Across E in {0.5, 5, 10} MPa and Poisson ratio in {0.45, 0.49} without retraining, mean s_c stays between 0.826 and 0.855 while the ROI alignment rate varies from 0.55 to 0.70, slightly higher for ν = 0.45. Sparse anchoring (~50% of default anchors) hurts Task 2 most: reward falls from 0.534 to −0.377, and Table V reports success dropping from 30.0% to 16.7% (the text describes the same drop as from 100.0% to 16.7%).
  • Cross-colon transfer is limited. For Colon 3 / 4 / 5 with the magnetic-driven endoscope, the constrained PPO policy trained on Colon 1 and Colon 2 succeeds consistently on Task 1 except on Colon 5, transfers moderately on Task 3 (50%, 70%, 50%), and largely fails on Tasks 2 and 4 (10–20%, or all failures). With proximal insertion it fails on all evaluated tasks in all three colons.
  • Parallel environments give a real speedup. At a matched budget of 44,000 transitions, five parallel environments reach 34.65 steps/s versus 12.22 steps/s with one, a 2.84× hardware-specific throughput improvement.

Methodology in Plain English

The authors take five real colons segmented from CT colonography scans, chosen with an expert abdominal radiologist (six years of clinical CTC experience) to represent typical scenarios: diverticula, redundant sigmoid or transverse segments, prone and supine scans of the same patient, and a case with 16 polyps. Each colon is turned into a triangular surface mesh and imported into NVIDIA Isaac Sim as a deformable object with a Young's modulus of 5 MPa and a Poisson ratio of 0.49. To stop the whole colon from drifting away, selected vertices at the rectum, ascending and descending colon, and the two flexures are pinned, leaving the sigmoid and transverse colon relatively free to deform as they do in real procedures.

The endoscopes are modeled two ways. The magnetic-driven scope is a chain of rigid cylindrical links joined by alternating-axis revolute joints, controlled with a 6-DoF velocity command (three translations, three rotations). The conventional scope is controlled only by proximal insertion plus rotation and distal pitch-yaw steering, a 4-DoF action that mimics pushing a real scope. The robot sees only stacked RGB camera frames; depth images are used only inside the simulator during training to compute the reward, either from Isaac Sim or from Depth Anything. The policy is a standard CNN-encoder actor-critic trained with four algorithms (PPO, constrained PPO, A2C, SAC) on a workstation with an Intel Core i9-10850K CPU and an NVIDIA RTX PRO 6000 Blackwell Max-Q GPU.

The reward has two parts. The first measures how well the deepest visible region of the depth image lines up with the image center. The second is a lumen-visibility score that returns a high value only when the lumen is actually visible and has reasonable depth range, which discourages the policy from pushing forward when the lumen is hidden by a fold or a sharp bend. The four navigation subtasks run from rectum, through sigmoid, along descending colon, to the sharp turn at the splenic flexure. They were not designed separately: a teleoperated insertion was recorded continuously, and the scope configuration at the end of each anatomical segment became the target of one task and the start of the next, preserving the flow of a real procedure. Success is judged by reaching the target, with each condition evaluated over 30 trials (three seeds, two evaluation runs, five parallel instances).

Why This Matters

Colonoscopy is the gold standard for detecting colorectal cancer, which the paper notes causes roughly 1.9 million new cases and more than 900,000 deaths annually. Because the procedure depends heavily on operator skill and causes discomfort through wall stretching and loop formation, autonomous or assistive navigation could make it easier and gentler. Before that is possible, the field needs a shared, physically realistic testbed, and this paper argues that existing benchmarks for laparoscopic robots and capsule-only colonoscopy simulators do not cover contact-driven flexible endoscope behavior. Its rigid-to-deformable transfer result (0 success after transfer) is direct evidence that simplified simulators can produce misleadingly good-looking policies.

Real-world applications:

  • Clinical training and skill assessment, where policies and humans can be compared on the same standardized subtasks and anatomies.
  • Pretraining and prototyping controllers for magnetic-driven and flexible endoscopic platforms before hardware trials.
  • Virtual evaluation of device designs, for example how tip actuation versus proximal push-off performs in redundant or diverticula-heavy colons.
  • Benchmarking RL algorithms and sim-to-real methods for deformable-object manipulation under contact, beyond endoscopy.

Industry relevance: the benchmark is built on NVIDIA Isaac Sim / Isaac Lab, is released open source, and was supported by the NVIDIA Academic Grant Program, making it directly usable by medical device companies and simulation teams working on endoscopic robotics.

Future Directions

  • Extending from the splenic flexure to full cecal intubation, which the authors explicitly name as future work; the current milestone covers only the left-colon insertion bottleneck.
  • Adding anatomies and richer sensing, specifically contact force measurement and robot shape sensing, to improve sim-to-real transfer.
  • Standardized safety metrics that capture tissue interaction forces and clinical constraints, rather than only reach-based success.
  • Solving proximal-insertion control, which the paper calls an open problem: distal advancement must emerge from shaft compliance, wall friction and colon deformation, creating a long-horizon credit-assignment and recovery challenge that current baselines do not handle.
  • Reducing sensitivity to fixation and material settings, since anchor density changed sigmoid-task outcomes substantially and remains a stated limitation.

Target Audience

RL researchers interested in deformable-object manipulation, contact-rich control and long-horizon navigation; surgical robotics groups working on endoscopic and flexible-instrument autonomy; medical device and simulation engineers who need a reproducible testbed for colonoscope control; and clinical collaborators who want to understand where learning-based colonoscopy navigation currently stands and what benchmarks exist.

Note: This paper is published under a CC BY-NC-ND 4.0 license and was funded by the European Union, grant number 101135082.

Authors’ abstract

Simulations for learning-based autonomous colonoscopic navigation focus mainly on fully actuated capsule robots, failing to capture the contact-rich navigation of long and flexible clinical colonoscopes. We present the Autonomous Robotic Colonoscopy Gym (ARCGym), an open-source reinforcement learning environment and benchmark for image-based navigation in clinically derived deformable colon anatomies. ARCGym supports multiple types of colonoscope robots, spanning capsule…

The full abstract on arXiv
Read the original paper