# Bi-manual Stabilization of the Cervical Spine for Safe Physical Human-Robot Interaction in Rolling Maneuvers

Robotics.world

> The cervical spine is fragile and vulnerable to catastrophic injury, so field medicine protocols emphasize keeping the head and neck aligned during patient movement.

**arXiv**: 2610.04220 · Preprint · not peer-reviewed

**Published**: 2026-10-03

**Authors**: Elizabeth Peiros, Moira Bohley, Lucas Yager, Derek Chen, Rebecca Fellbaum, Chris D'Ambrosia, Ananya Rao, Xiao Liang, Michael C. Yip

## In plain words

The cervical spine is fragile and vulnerable to catastrophic injury, so field medicine protocols emphasize keeping the head and neck aligned during patient movement. Rigid collars are common but are associated with risks such as increased intracranial pressure and reduced airflow, and best practice favors a dedicated person to stabilize the head by hand.

## AI summary

## Overview

- **Research area:** Physical human-robot interaction, medical and rescue robotics, and bimanual manipulation.
- **Technical level:** Intermediate.
- **Scope:** This paper develops and evaluates a bimanual humanoid robot that grasps and stabilizes a patient’s cervical spine during rolling maneuvers, with performance compared against human novices and experts on a sensorized phantom.

## What This Paper Is About

The cervical spine is fragile and vulnerable to catastrophic injury, so field medicine protocols emphasize keeping the head and neck aligned during patient movement. Rigid collars are common but are associated with risks such as increased intracranial pressure and reduced airflow, and best practice favors a dedicated person to stabilize the head by hand. This paper asks whether a bimanual robot can take that role, grasping the head around the ears and maintaining an “ears over shoulders” alignment during a roll without compressing or distracting the neck.

## Key Contributions

1. **A neck-stabilization algorithm** that uses body tracking to define trajectories keeping the neck straight and uncompressed, with the ears over the shoulders, and that reorients the head relative to the torso during rolling.
2. **Deformable hand pads optimized for grip** to maximize the ratio of grasp resistance to contact pressure while staying below biomechanical safety thresholds.
3. **A sensorized testing phantom** with a force-torque sensor and a biomechanically representative neck joint, enabling direct comparison between robot and human performance.
4. **A Gaussian-process torso-motion predictor** that reduces tracking-to-actuation lag by predicting the torso’s next pose and servoing the hands toward that predicted pose.

## Main Findings

- **Grasp success was limited by workspace:** Across 14 trials with varied initial head poses, the robot successfully grasped the head in 9 trials, concentrated in front of the robot with minimal allowed head angle. The G1’s smaller limb length and degrees of freedom constrained orientation variation.
- **Softer pads improved grip:** Adding deformable, tacky silicone pads substantially improved grasping. Ecoflex 00-10 achieved the highest force-to-pressure ratio of 1.574 at 3 N, but it was too soft to be durable for testing.
- **Ecoflex 00-20 at 3 N was selected:** This configuration produced a 12.43 kPa contact pressure, 18.72 N of resistance force, and a ratio of 1.506, balancing high grip with low pressure on the skull.
- **Dragon Skin 20 performed poorly:** Its ratios were 0.201 at 3 N, 0.177 at 5 N, and 0.206 at 7 N, far below the Ecoflex materials.
- **Human baselines:** Experts (n=21) had a median maximum axial rotation error of 6.68° and a median maximum angular distance from the center axial line of 7.59°. Novices (n=56) had 9.64° and 10.59°, respectively.
- **Robot without prediction:** The robot (n=12) kept axial alignment within 13.66°, other degrees of freedom within 23.12°, and maintained force under 8 N.
- **Robot with prediction:** The predictive model (n=12) achieved a median maximum axial rotation of 9.85°, which is 0.21° from the novice median of 9.64° and below the 10° maximum allowable deviation, while the other directions reached 23.4°.
- **Prediction improved alignment but not disturbance rejection:** The predictive model aligned better but reacted less well to disturbances and produced higher reaction forces along the neck base.
- **Overall performance was below human level for bending:** Some trials met the requirements and matched human metrics, but the robot did not match human capability in preventing neck bending.
- **Constrained null space:** The bimanual grasp reduced the available null space from 2 degrees of freedom, one per arm, to 1 degree of freedom, making it difficult to optimize multiple head angles while also minimizing reaction forces.

## Methodology in Plain English

The robot first uses a head-mounted camera to locate two ArUco markers, one on the casualty’s head and one on the torso, and converts their poses into clinically meaningful head and torso frames. It then plans both arms to positions on either side of the head using RRT* with collision checking, followed by a PD controller for end-effector position control; gravity compensation is applied during non-contact motion.

Once in position, the dexterous hands squeeze inward along the head frame until a calibrated grip threshold is reached. The grip force is chosen through an optimization that models the silicone pads as deformable spheres pressing into a rigid wall, maximizing resistance to disturbance while keeping contact pressure below 1.3 MPa.

With the head grasped, the robot measures the head-to-torso angular difference, filters it through a median filter, an exponential moving average filter, and a slew-rate limiter, and then commands the hands to reorient the head to the neutral “ears over shoulders” orientation while holding translation fixed to avoid compression or distraction. A Gaussian process trained on 200 input-target pairs subsampled from 40 episodes predicts the torso’s next pose, and the hands are servoed toward that predicted pose rather than the last measured one.

Testing used a phantom with a spherical bearing for unlimited axial rotation, a cone limited to 45° for 90° of lateral bending and flexion-extension, and a BOTA SensONE Gen A force-torque sensor at the neck base. The robot platform was a Unitree G1 humanoid with a D435 RealSense camera and Inspire RH56DFTP hands, with 7 degrees of freedom per arm. Human trials used OptiTrack Trio V120 cameras, with a “user” stabilizing the head and a “teammate” rolling the torso.

## Why This Matters

This work takes an early step toward robots that can perform a delicate, safety-critical clinical task rather than only lifting or dragging casualties. It also provides a controlled comparison between robot and human performance on the same phantom, which the authors describe as a level playing field not seen in other works of its kind.

Real-world applications include:

- **Battlefield and combat casualty evacuation**, where personnel and time are limited and rigid collars may be the only alternative.
- **Wilderness medicine and solo rescue**, where a robotic teammate could provide head stabilization without a dedicated human helper.
- **Emergency medical services and patient transfers**, where maintaining airway and spinal alignment is a recurring requirement.
- **Athletic injury response and disaster response**, where suspected spinal injuries require careful rolling and transport.

For industry, the results are relevant to humanoid robotics, care robotics, compliant gripper design, and safe physical human-robot interaction. The finding that added grippers increased grasp strength without overheating the robot from continuous force regulation is also directly useful for hardware designers.

## Future Directions

- **Higher-degree-of-freedom, more human-like hardware:** The authors suggest that future hardware with a larger workspace and more null space could improve multi-axis alignment and reaction-force minimization.
- **End-effector force sensing and impedance control:** Adding high-fidelity force sensing could enable an impedance controller that does not interfere with the grip direction, or feed force feedback into the planner to select better trajectory points.
- **Better disturbance rejection in prediction:** The predictive model improved alignment but produced higher reaction forces, so combining prediction with robust disturbance response is an open problem.
- **Broader evaluation:** Testing across more rolling maneuvers, more initial poses, and eventually human subjects would clarify whether the approach generalizes beyond the phantom setup.

## Target Audience

This paper is most useful for robotics researchers working on physical human-robot interaction, medical and rescue robotics, and bimanual manipulation, as well as engineers designing compliant grippers and safe control systems for humanoids. Clinicians and field-medicine collaborators interested in robotic assistance for spinal stabilization will also find the safety framing and phantom methodology relevant.

## Authors’ abstract

The neck, specifically the cervical spine, is a highly fragile and mobile part of the body with a high risk of catastrophic injury. Whether someone is injured on a battlefield, in a natural disaster, or in an athletic event, great care is always taken with the cervical spine when transporting, rolling, or moving the patient. In this work, we present an algorithm and adaptations for bi-manual robots to stabilize the cervical spine during rolling maneuvers. We investigate…

[The full abstract on arXiv](https://arxiv.org/abs/2610.04220)

[Read the original paper](https://arxiv.org/abs/2610.04220)

## Related papers

- [Integrated Respiratory Sensing and Gated Control for Autonomous Needle Insertion Via CT Bore Robotic Arm](https://robotics.world/paper/integrated-respiratory-sensing-and-gated-control-for-autonomous-needle-2610.30452) 2026-10-21 · cs.RO · Also by Ananya Rao, Derek Chen +3
- [Physical Twins: Accelerating and Enabling Robot Learning with Phantom Platforms](https://robotics.world/paper/physical-twins-accelerating-and-enabling-robot-learning-with-phantom-2610.06929) 2026-10-03 · cs.RO · Also by Derek Chen, Elizabeth Peiros +2
- [Sub-Millisecond Reflexes for Continuous Physical Human-Robot Interaction](https://robotics.world/paper/sub-millisecond-reflexes-for-continuous-physical-human-robot-interaction-2610.21913) 2026-10-15 · cs.RO · Key terms of the title in common
- [A Physics-Consistent Benchmark for Contact-Rich Human-Robot Interaction in Assistive Care](https://robotics.world/paper/a-physics-consistent-benchmark-for-contact-rich-human-robot-interaction-2609.02402) 2026-09-02 · cs.RO · Key terms of the title in common
- [Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training](https://robotics.world/paper/robust-surgical-robotic-instrument-tracking-via-sequential-multi-cue-2610.05491) 2026-10-04 · cs.RO · Also by Michael C. Yip

---

Canonical: https://robotics.world/paper/bi-manual-stabilization-of-the-cervical-spine-for-safe-physical-human-2610.04220