Research
Camera equalisation of an 11.5x drop in environmental illuminance: four imitation-learning policies on an SO-101 arm
Robotics papers typically describe lighting conditions by reporting room illuminance in lux, assuming that equal lux means the policy sees equal images. This paper tests that assumption on a low-cost…

- arXiv
- 2611.13810 · Preprint · not peer-reviewed
- Published
- 2026-11-10
- Authors
- Simon Cowling
In plain words
Robotics papers typically describe lighting conditions by reporting room illuminance in lux, assuming that equal lux means the policy sees equal images. This paper tests that assumption on a low-cost rig by running four popular imitation-learning policies (ACT, SmolVLA, Diffusion Policy and π_0.5) through the same pick-and-place task at about 520 lux and again at about 45 lux.
AI summary
Overview
Research area: Real-robot evaluation of learned visuomotor manipulation policies (imitation learning), specifically the effect of lighting on camera inputs.
Technical level: Intermediate. The core idea is intuitive, but the paper uses statistical intervals, odds ratios and image-statistics measurements that assume some familiarity with robotics benchmarking.
Scope: A paired real-robot study of four imitation-learning policies on a single SO-101 arm, measuring whether an 11.5× drop in room illuminance changes pick-and-place success, and what the cameras actually recorded.
What This Paper Is About
Robotics papers typically describe lighting conditions by reporting room illuminance in lux, assuming that equal lux means the policy sees equal images. This paper tests that assumption on a low-cost rig by running four popular imitation-learning policies (ACT, SmolVLA, Diffusion Policy and π_0.5) through the same pick-and-place task at about 520 lux and again at about 45 lux. The goal is to separate what happens to the room's light from what actually reaches the policy's input.
Key Contributions
- A paired real-robot comparison of four policies under an 11.5× illuminance drop. 80 rollouts in total, with per-policy effect estimates and 95% intervals, plus pooled odds ratios stratified by policy.
- Direct measurement of what the cameras recorded. Every frame of every rollout was decoded and measured for brightness, contrast, sharpness, saturation and white balance, then compared against 20 training episodes.
- A same-day repeat of one 10-rollout block, which quantifies how much a single block varies on its own even when the model and light are held roughly constant.
- Practical recommendations for small real-robot benchmarks, centred on logging camera settings and comparing image statistics against the training data rather than relying on lux alone.
Main Findings
- Room light dropped far more than image light. Workspace illuminance averaged 519 lux in normal light (block range 477–556) and 45 lux in low light (41–51), a ratio of 11.5×. Yet mean image brightness fell only 3% on the front camera and 19% on the wrist camera.
- Success barely changed. 20/40 rollouts succeeded in normal light and 19/40 in low light, a change of −2.5 percentage points (95% CI −23 to +19).
- No per-policy difference in sensitivity. ACT and SmolVLA each changed by −10 points, Diffusion Policy by +10, and π_0.5 by 0. All Fisher and McNemar p-values were 1.00; the interaction p was 0.86 and the Breslow–Day p was 0.86, though per-policy intervals span roughly ±40 points.
- Large drops are unlikely but modest ones are not excluded. The posterior probability of a policy-averaged drop of 20 points or more is 0.024; a drop of 10 points or more has probability 0.19.
- Automatic camera settings absorbed the change. Both cameras were set to automatic exposure and automatic white balance when read after the experiment. Lux at the front and wrist camera positions fell 10.7× and 10.2×, while mean luma fell only 1.03× and 1.24×.
- The wrist camera changed most. It was 19% darker and 8% lower in contrast in low light. Raw sharpness fell 34%, but normalised for brightness it did not change (133 vs 134), so there is no evidence of added motion blur.
- Frame rate held up. Repeated frames rose only from 10% to 13% on the front camera and 7.5% to 9.4% on the wrist camera; a halved frame rate would produce about 50%.
- Normal light was itself off-distribution. Normal-light images were warmer and 47% more saturated than the training recordings despite matching the recording lux. On the wrist camera, contrast (34.3 vs 40.3) and normalised sharpness (133 vs 185) were both below training.
- Failure modes did not shift measurably. Permutation p = 0.77. Grip failures rose from 6 to 10 across all policies (Fisher p = 0.40), mostly in SmolVLA (2 to 5; Fisher p = 0.35).
- Placements carry some structure. Outcomes matched across conditions at 29 of 40 policy × placement pairs against 23.6 expected under independence; the placement term in the GLM gave p = 0.033.
- A single block is noisy. The accidental DP low-light repeat at 51 and 59 lux reproduced the success count (7/10 both times) but matched the first block at only 6 of 10 placements, consistent with chance (φ = 0.05).
- Brighter episodes succeeded more often in low light, but only weakly and only on the front camera (r = 0.40 across 40 rollouts, p = 0.02; within-policy logistic slope 0.28 per grey level, p = 0.06; wrist p = 0.74). The authors read this as a property of episode content rather than a lighting effect.
Methodology in Plain English
The setup is a 6-DoF SO-101 follower arm driven through LeRobot (pinned at commit ba83e4cf) on one workstation with an RTX 5070 Ti. Two off-the-shelf USB cameras stream at 640×480 and 30 fps: a fixed Logitech Brio 300 in front and a generic USB 2.0 module on the wrist. The task is to pick up a green ball and place it in a basket while ignoring two red distractor balls, with a 30-second limit per rollout.
All four policies were trained on the same 50 teleoperated demonstrations recorded at about 500 lux, using LeRobot's reference configurations. ACT ran 30,000 steps at constant learning rate, SmolVLA 6,000 steps (cooldown from 4,800), Diffusion Policy 50,000 steps (cooldown from 40,000), and π_0.5 6,000 steps (cooldown from 4,800).
Testing happened over two consecutive days. On 5 November the room's artificial lights were on with daylight unscreened (normal). On 6 November every artificial light was off and daylight was reduced with screens and blockers (low). Note that this changed the light's source, colour and direction as well as its level. Each block was ten rollouts, one per fixed placement N00–N09, run in the same policy order on both days. One unblinded operator placed the ball and scored each rollout live as success, started, and a failure label (location, grip, ball knocked out of reach, or wrong object).
Analysis used risk differences with Newcombe 95% intervals, Fisher exact tests, exact McNemar tests over placements, a Mantel–Haenszel odds ratio stratified by policy, and binomial GLMs with policy and placement fixed effects. Every frame of every rollout was decoded and measured for brightness (Rec. 601 luma), contrast, sharpness, saturation and white balance, and compared with 20 training episodes. The analysis is explicitly exploratory and the p-values are described as descriptive.
Why This Matters
Impact on research: The paper challenges a common benchmarking convention. If a tenfold change in room light can leave image brightness nearly unchanged, then logging lux is not a meaningful description of a policy's visual input. The authors argue that camera settings and image statistics relative to the training data are the quantities to report and control. The finding also helps explain a discrepancy in the literature: simulated benchmarks that perturb rendered images directly rank lighting among the most damaging changes, while a real VLA robustness suite finds it much less damaging than camera-viewpoint changes. A real camera's exposure and white-balance control filters the room's light before the policy ever sees it.
Real-world applications:
- Warehouse and fulfilment robotics, where pick-and-place cells see lighting drift across a shift as daylight changes and overhead lights cycle.
- Home and service robots, which operate in rooms where occupants turn lights on and off and where windows change the ambient level throughout the day.
- Agricultural and field robotics, where outdoor illumination varies by orders of magnitude between dawn, noon and dusk.
- Laboratory reproducibility and benchmarking, where small real-robot studies need to report conditions that another lab could actually match.
Industry relevance: Camera auto-exposure is doing part of the job that photometric augmentation and domain randomisation do during training. Teams deploying low-cost arms with commodity USB cameras get substantial lighting tolerance "for free" from the sensor pipeline. But that tolerance is undocumented and can silently reset when a camera is reconnected, which is a real operational risk for anyone qualifying a policy on a bench and then deploying it.
Future Directions
- Test with exposure locked. Every policy here saw images that were barely darker than training, so the study does not show that any of the four policies is robust to genuinely dark images. Locking exposure at the training setting is the direct test the authors recommend and did not run.
- Compare pretrained and from-scratch encoders under real image degradations. The data say nothing about whether vision-language-pretrained encoders (SmolVLA, π_0.5) are more robust than an ImageNet-initialised (ACT) or from-scratch (DP) ResNet-18, because the image changes were too modest to elicit a response.
- Run larger blocks. Ten rollouts per cell detect only very large per-policy changes; a 70%-to-40% drop is detected with probability about 0.12. The authors identify the blocked design as the informative comparison and point at the noise floor a single block imposes.
- Test the perturbations that were excluded. Hard shadows, glare, flicker, and brighter-than-training light were not tested, nor was any condition that varies the light source independently of its level.
Target Audience
Researchers and engineers running small real-robot evaluations of learned visuomotor policies, especially those using low-cost arms and commodity USB cameras. It is directly useful to anyone writing a benchmark protocol, reviewing a robotics paper's experimental section, or debugging why a policy that worked on the bench behaves differently elsewhere. The paper also serves as a compact, honest example of exploratory methodology: it reports its own unplanned repeat, states its power limits explicitly, and marks its p-values as descriptive.
Authors’ abstract
Real-robot benchmarks of learned visuomotor policies often record room illuminance as the lighting condition. We show that, on a typical low-cost rig, room light and image light can be almost unrelated. Four imitation-learning policies (ACT, SmolVLA, Diffusion Policy and pi0.5) were trained on the same 50 demonstrations of a pick-and-place task on an SO-101 arm. Each was run for ten rollouts at about 520 lux and again at about 45 lux, an 11.5x reduction. Success was 20/40 in…
The full abstract on arXivRelated papers
- Does Validation Loss Predict Real-Robot Success? Evidence from Four Imitation-Learning Policies on a Low-Cost Arm 2026-10-30 · cs.RO · Also by Simon Cowling