Research
Curie's Jarvis: Autonomous Robotic Chemistry Experiments from Printed Protocols
A person doing a bench experiment reads a printed protocol, distinguishes identical cups by the labels they sit on, and re-checks the bench before every step.

- arXiv
- 2611.13251 · Preprint · not peer-reviewed
- Published
- 2026-11-09
- Authors
- Rumi Loghmani, Bozhang Song, Victor Alvarado, Aliyah Redding, Amir Barati Farimani
In plain words
A person doing a bench experiment reads a printed protocol, distinguishes identical cups by the labels they sit on, and re-checks the bench before every step. Most lab robots work the opposite way: the procedure must be rewritten as a script, containers must sit at fixed positions or carry fiducial markers, and objects that get moved can stop a run.
AI summary
Overview
Research area: Robotics for laboratory automation — combining vision-language models (VLMs), multi-view perception, and manipulation skills so a robot arm can execute chemistry protocols from a photograph of a printed instruction sheet.
Technical level: Intermediate. The paper assumes familiarity with robot manipulation pipelines (grasp planning, point clouds, camera calibration) and with using large models as planners, but its argument is mostly about system design and evaluation rather than new theory.
Scope: The paper describes and evaluates Curie's Jarvis, a system built on a Franka Emika Panda arm that runs two children's chemistry-kit protocols from a photographed instruction sheet, on an ordinary bench with unmarked, loosely labelled containers (arXiv:2611.13251v1 [cs.RO], 09 Nov 2026; authors from the Department of Mechanical Engineering, Carnegie Mellon University).
What This Paper Is About
A person doing a bench experiment reads a printed protocol, distinguishes identical cups by the labels they sit on, and re-checks the bench before every step. Most lab robots work the opposite way: the procedure must be rewritten as a script, containers must sit at fixed positions or carry fiducial markers, and objects that get moved can stop a run. Curie's Jarvis is built to work on a bench set up for people — reading steps from a photo of the sheet, finding containers with no fixed positions or markers, telling identical containers apart by reading handwritten or printed labels across four camera views, re-locating its target before each step, and adapting how each step is performed (speed, pour angle, scoop depth) to what is being handled.
Key Contributions
- A complete system that runs a chemistry experiment from a photo of the printed sheet. On a Franka Panda arm, on a bench with no fixed positions or markers, it completed 5 of 5 Magic Beaker runs and 4 of 5 jellyfish runs with no human intervention.
- Label-based identification of identical-looking containers. Each container stands on a slip of paper naming its contents; the VLM (GPT-4.1) reads the label in each of four camera views and the reads are combined by a cross-camera vote. Positions come from multi-view geometry, so the label only has to say what the container is and can be placed loosely. In 160 locates on printed labels and the handwriting of three people, every container was identified correctly.
- Re-locating and re-identifying targets before every skill call, so a container moved between steps — even among identical-looking ones — is found at its new spot; the identity comes from the label vote rather than from where the container stood before.
- Execution parameters chosen from what is handled. The model picks the pour angle from the wording of the step and the speed from what is held (a scoop of powder versus an empty tool), a fixed rule assigns angles when the same container is poured from or into more than once, and scoop depth comes from the measured powder surface.
Main Findings
- End-to-end success: Magic Beaker succeeded in 5 of 5 runs and jellyfish in 4 of 5 (Table IV), with no human intervention. The paper reports about 30 minutes per Magic Beaker run and about 17 minutes per jellyfish run in the text, while Table IV lists 19 minutes for jellyfish; Section VII-E separately describes a Magic Beaker run as taking about 20 minutes. Every successful run ended with the visible result its sheet describes: in Magic Beaker the mixed liquid fizzed and turned purple; in jellyfish the indicator drops sank through the oil and turned blue.
- The single failure was a tool-recognition error: in the failed jellyfish run, the system took the scoop for the pipette and grasped the scoop at the final pipetting steps. Tools carry no label by design, so the label vote cannot catch this; the pipette is found only through the text prompt given to SAM 3.
- Label reading was perfect across 160 locates: 40/40 for the printed set and 40/40 for each of three handwriting sets, with a mean offset of 0.2 mm from ground truth and at most 1.1 mm. All four cameras read the label in 139 of 160 locates (35/40 printed, 33/40, 32/40 and 39/40 for the three handwriting sets).
- The cross-camera vote matters: in 21 of the 160 locates a single camera misread the label on the right container (camera 3 in 11, camera 4 in 9, camera 2 once), and no locate had more than one camera misreading, so the others outvoted it. Camera 3 used alone would have found at most 149 of the 160 containers.
- Moving a container off its label causes misses, not misidentifications: across 96 locates with containers moved 2 to 44 cm from their labels, no locate returned the wrong container — every miss was "not found". With the other three labels left on the bench, 48/48 were found (elimination recovered 10 of them); with those labels removed, 32/48 were found and 16 of 48 were not.
- Readability depends on the label being beside the container, not on distance: the water cup was read by all four cameras 18 cm from its spot while standing against the edge of its paper, and was not found at 16 cm with bare table between it and the paper; the baking soda dish was not read at 6 cm when it stood on top of its own text.
- Open-vocabulary segmentation plus multi-view geometry handles both opaque and transparent objects: opaque objects are back-projected from depth with cameras agreeing within 50 mm; for transparent containers, whose depth centroids from four cameras were up to 6 cm apart, rays cast through each mask's centroid must pass within 25 mm of one point (on four containers the rays passed 6 to 11 mm from that point).
- Perception is the bottleneck for run time: a locate with all four cameras took 14.1 s on average (13.2 to 18.1 s). The four RealSense streams could not be opened simultaneously (USB controller overload) and SAM 3 could not segment all four views together in GPU memory, so cameras are read one at a time.
- Prompt wording matters for instruction parsing: without a line telling the model to keep each step's own wording, it read "the empty clear cup" as "the beaker" in 2 of 3 reads; with that line, it read the step correctly in 3 of 3.
- P4 (robustness to people moving things) and P5 (adapted execution) are implemented but not evaluated on their own. Section VII-D explicitly states no experiment has yet been run with a person moving objects mid-run; Section VII-E states the same for adapted execution, though all ten end-to-end runs used the speeds the agent chose.
Methodology in Plain English
The system runs on a Franka Emika Panda arm with a parallel-jaw gripper, surrounded by four Intel RealSense D415 RGB-D cameras on a cage, calibrated to the robot base using a cube held by the gripper (used only for calibration). The bench holds ordinary kit equipment: shallow white dishes of powders, clear plastic cups, a plastic beaker, a plastic transfer pipette standing in a lidded paper cup, and 3D-printed scoop, stirrer and stirrer holder — each container sitting on a paper slip with its contents written or printed on it.
The software is split into four GPT-4.1 agents, following the modular structure of PLATO. Once per run, an instruction parser turns a photo of the sheet into a goal, ordered steps, reagents and equipment as JSON; a scene agent names the objects on the bench by choosing from a supplied list (it is told what things are called, not where they are); and a planner decomposes the goal into ordered sub-tasks. For every sub-task, a skill-call agent returns exactly one call, constrained by a JSON schema to a fixed set of skills, plus parameters, a speed and a short reason. Anything a call leaves out is filled with a value tuned on this bench.
Segmentation (SAM 3) runs as a separate GPU service. To find an object, each camera's colour and depth images are read in turn, SAM 3 returns instances for a text prompt (a category like "white bowl" or "clear plastic cup", or a tool description like "white plastic tool"), and positions are fused across views — from depth for opaque objects, and from converging rays for transparent ones. Identical containers of one category form a vote group: the labels are distributed one container each so that the most camera reads agree, and a container is resolved by label, by elimination (when all other labels in the group are settled and one container is left), or returns not found.
Manipulation is a set of skills — scoop and dump, pour, stir and tool return, pipette pick and dispense, and put-back — each of which locates its target from a home pose out of camera view before acting, plans motion from measured geometry (a cup's rim circle, a held object's measured shape), executes, and then checks that its moves ended near their targets and that the gripper width shows nothing was dropped. Scoop depth is set from the measured powder surface; pouring places the lip just inside the target rim and recomputes the wrist position at each tilt step. Skills and agents were first developed in a MuJoCo model of the bench, with default parameters then set on the real bench.
If a skill fails, the failure, the sub-tasks already done and the reason go back to the planner, which replans up to three times before the run stops. Every call, outcome, timing and measurement is written to a run record, and an operator can step through a run or resume a stopped run from a chosen sub-task.
The evaluation used two protocols from a National Geographic Kids chemistry kit, given to the system only as a photo of the printed sheet: Magic Beaker and jellyfish. Each was run 5 times; a run counted as a success when every sub-task was carried out with no human intervention and the expected visible result appeared. Reagents came pre-measured into their own containers, so the robot transfers and mixes but does not measure amounts. Separately, the label experiments used four containers in a square (two identical white dishes, a clear plastic cup, a plastic beaker), with only the cameras used and all memory cleared before each locate.
Why This Matters
Lab automation is typically fast and accurate precisely because the experiment is adapted to the robot — scripts, fixed stations, AprilTags. That makes every new experiment a reprogramming job, and a moved object a potential dead end. Curie's Jarvis shows that the reverse direction is feasible: the robot adapts to a bench laid out for people, reading the same printed sheet and the same handwritten labels a human would read. The reported 160/160 label-reading result, and the fact that no locate across the 96 move-away trials ever returned the wrong container, suggests label-based identity is a viable and safer alternative to fiducial markers, where a miss degrades to "not found" rather than to a wrong-reagent action.
Real-world applications:
- Reproducing published or teaching-lab protocols that exist only as printed or PDF instruction sheets, without rewriting them as scripts.
- Shared, cluttered bench environments where people move glassware between steps, and where per-object tags are impractical to maintain.
- Educational and low-resource labs using kit-scale equipment rather than fixed liquid-handling stations.
- Situations where the identity of a container must be legible to both humans and the robot at once — the label carries no calibration and needs no fixed orientation.
Industry relevance: The paper is direct evidence for the "flexible automation" pitch in lab robotics: a system whose setup cost for a new protocol is a photograph rather than a script. Its stated bottlenecks — sequential camera reads making perception dominate run time (14.1 s per locate, roughly 30 sub-tasks per Magic Beaker plan), and dependence on a hosted VLM requiring a network connection — are concrete engineering targets for anyone building commercial bench robots.
Future Directions
- Evaluating P4 and P5 directly. The authors state that robustness to people moving objects mid-run and adapted execution have not yet been tested on their own, and name as next steps testing with people moving objects during a run and comparing the speeds the system chooses against fixed ones.
- Moving to protocols that need measured amounts. The clearest stated limitation is that reagents are pre-measured and the robot does not weigh or otherwise measure what it transfers, so the results say nothing about delivery accuracy — which most real protocols require.
- Faster perception. Because cameras are read one at a time (USB overload, GPU memory limits for SAM 3 on four views), locates are a large share of run time; the authors note that a computer able to stream and segment all four cameras at once would remove most of that wait.
- Better unlabelled-tool recognition. The single failed run came from confusing the scoop with the pipette, which is found by a SAM 3 text prompt alone; the authors expect a stronger VLM to identify the pipette and choose its prompt better. They also note the top-down cameras hide the underside of the scoop's head, making its measured depth only a lower bound.
Target Audience
Robotics researchers working on manipulation, task planning, and VLM-driven agents — particularly those interested in perception for transparent and unlabelled objects, and in closed-loop replanning. It is also relevant to lab-automation and self-driving-laboratory engineers weighing marker-based versus label-based identification, and to readers interested in what it takes to move a robot from scripted protocols to human-format instructions. The paper is written so that the evaluation protocol and its caveats (pre-measured reagents, one bench, one arm, two kit protocols, two properties untested in isolation) are legible to non-specialists.
Authors’ abstract
A person running a bench experiment works from a printed instruction sheet, tells identical containers apart by the labels written on them, and looks at the bench again before each step. Lab automation usually works the other way around: the procedure is written as a script, and containers stand at fixed positions or carry fiducial markers. We present Curie's Jarvis, a system that lets a robot arm carry out a chemistry experiment on a bench set up for people. It reads the…
The full abstract on arXivRelated papers
- Grasp-Taxonomy Conditioning as a Mode Switch for Dexterous Grasping of Climbing Holds 2026-11-09 · cs.RO · Also by Amir Barati Farimani, Rumi Loghmani
- JARVIS: From Visual Manuals to Autonomous Robotic Assembly 2026-10-20 · cs.RO · Key terms of the title in common
- AeroBuoy: A Drone Deployable, 3D Printed, Autonomous Robotic Buoy for Environmental Inspection in Remote and Hazardous River Systems 2026-10-05 · cs.RO · Key terms of the title in common
- An Autonomous, 3D Printed, Waterjet-Powered, Open-Source Robotic Trimaran for Environmental Inspection and Monitoring 2026-10-05 · cs.RO · Key terms of the title in common
- A Benchmark and Layered Evaluation Protocol for Evidence-Grounded Shared Belief Updating in Connected Robotics 2026-11-09 · cs.RO · Key terms of the title in common