Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

Robot-assisted minimally invasive surgery currently ties the surgeon to a bulky stationary console that displays a single endoscopic viewpoint, which limits depth perception and disrupts natural…

The paper’s first page · arXiv:2609.25527
arXiv
2609.25527 · accepted · IROS
Published
2026-09-22
Authors
Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei, Adnan Munawar, Mathias Unberath, Peter Kazanzides

In plain words

Robot-assisted minimally invasive surgery currently ties the surgeon to a bulky stationary console that displays a single endoscopic viewpoint, which limits depth perception and disrupts natural hand–eye coordination.

AI summary

Overview

Research area: Surgical robotics, teleoperation interfaces, extended reality (VR/MR), and perception-driven digital twins.

Technical level: Advanced. The paper assumes familiarity with the da Vinci Research Kit (dVRK), SE(3) pose algebra, hand–eye calibration, and vision foundation models (SAM 2, SAM 3, FoundationPose).

Scope: The paper presents a VR teleoperation platform for the dVRK in which a Unity digital twin, built from markerless RGB-D perception and streamed robot state, replaces endoscopic video pass-through, and it evaluates that platform against a HoloLens 2 mixed reality baseline and the traditional MTM console in a 15-participant user study.

What This Paper Is About

Robot-assisted minimally invasive surgery currently ties the surgeon to a bulky stationary console that displays a single endoscopic viewpoint, which limits depth perception and disrupts natural hand–eye coordination. Console-free alternatives using head-mounted displays exist, but they typically stream video and force the operator to keep their hands physically aligned with the instruments, and most rely on fragile bare-hand tracking. The authors build a VR teleoperation platform for the dVRK that renders a live digital twin of the robot and the manipulated objects inside a Meta Quest 3S headset, allowing multiple viewpoints and letting the operator's hand posture be decoupled from instrument alignment.

Key Contributions

  1. A digital twin-driven VR teleoperation framework that replaces video streaming with state synchronization, enabling unconstrained multi-view rendering for improved depth and spatial perception.
  2. A clutch-anchored teleoperation paradigm that uses stable 6-DoF VR controllers to safely decouple user hand posture from instrument alignment, clutching translation and rotation simultaneously rather than preserving absolute rotational mapping as the da Vinci paradigm does.
  3. A camera-centric registration method that bypasses the inaccurate Setup Joint (SUJ) kinematics of the dVRK via hand–eye calibration, making the RGB-D camera frame the Unity world origin so that robot and object twins align without extra object-side calibration.
  4. A 15-participant user study showing that VR significantly outperforms a state-of-the-art HoloLens 2 MR baseline in trajectory quality, with spatial judgment comparable to or better than the traditional console.

Main Findings

  • Trajectory quality versus MR: Compared with the HoloLens 2 MR baseline, VR reduced path length by 86% and jerk by 95% (both p < .001).
  • Trajectory quality versus the console: VR also significantly outperformed the traditional MTM console in path length (p = .037), motion efficiency (p < .001), and smoothness (p < .001).
  • Task time: The MTM console had the lowest mean task time (37.4 s), followed by VR (54.6 s) and MR (85.2 s); the VR–MR difference was not significant after Bonferroni correction (p = .219), nor was VR–MTM (p = .506).
  • Depth-perception confidence: Mean gripper closures, used as a proxy for confidence in depth estimation, were lowest for VR (1.27), then MR (1.47), then MTM (1.73).
  • Why MR struggled: High variance in the MR condition was attributed to hand tremors, tracking loss, recognition errors, and a gesture-based clutch prone to accidental misoperation during bare-hand mid-air operation.
  • Why the console produced high jerk: The MTM's absolute orientation alignment on clutch re-engagement penalized users who did not hold a consistent hand orientation while clutched, producing abrupt positional transients.
  • Subjective ranking: MTM scored highest overall on Borda scoring across five dimensions, with VR consistently second and well ahead of MR; the gap was narrowest for ease of learning (2.27 vs. 2.47) and precision (2.13 vs. 2.40).
  • Multi-view feedback: 87% of participants rated multi-view rendering helpful or very helpful; 80% cited improved depth perception and 67% a better understanding of tool pose; 80% preferred the flexible multi-view mode over a fixed endoscopic view.
  • Latency: The teleoperation control loop measured 59.7 ms end-to-end; on an NVIDIA RTX 3080 Ti, SAM 2 segmentation took 157.4 ± 6.5 ms and FoundationPose pose estimation took 50.9 ± 10.2 ms per frame.

Methodology in Plain English

The system runs three asynchronous data flows instead of one video feed. First, the dVRK streams high-rate joint states over UDP, which Unity uses to update a kinematic model of the Patient Side Manipulator, including its Remote Center of Motion constraint, so the operator can see the full arm configuration. Second, an external RGB-D camera sends images to a perception server, where SAM 2 isolates each object from a minimal point or box prompt, optional SAM 3 semantic labels help keep track of similar objects, and FoundationPose recovers each object's 6-DoF pose. These poses are streamed to Unity, buffered, smoothed with a first-order low-pass filter for translation and quaternion SLERP for rotation, and held at the last valid pose during tracking dropouts. Third, Meta Quest 3S controller poses and button inputs are converted into dVRK motion commands and sent back to the robot.

To align the virtual and physical worlds, the authors perform hand–eye calibration between the camera, the robot base, the tool tip, and a marker on the tool shaft, then redefine the robot's base frame in the controller configuration so that Cartesian output is already expressed in the camera frame, which is also the Unity world origin. This avoids drift from the Setup Joint kinematics.

For control, the middle trigger on the controller is the clutch: on engagement the system records the controller pose and robot tip pose as an anchor, and subsequent controller motion is mapped relative to that anchor with a scale factor, rather than integrated frame to frame. Both translation and rotation are clutched, so users can reposition and reorient their hands ergonomically. Jaw angle is mapped linearly from middle-trigger press depth between −10° and 60°; a jaw stall at a non-fully-closed angle triggers a haptic vibration as grasp confirmation, and a jaw-lock mode latches the current angle. Users switch discrete motion scale levels with the Y/B buttons.

The interface renders the native workspace view plus an extra fixed endoscopic view for cross-checking. Because the twin is driven by lightweight state rather than video, recorded sessions can be replayed offline with multiple virtual cameras rendering arbitrary viewpoints.

The evaluation used a within-subject design: 15 volunteers (9 male, 6 female; 9 with prior dVRK experience, 11 with prior VR/AR exposure) each used MTM, MR, and VR in randomized order. The task was to grasp a vertically oriented 3D-printed ring and place it on a target peg, with participants closing the gripper only when they believed alignment was perfect. Metrics were task time, number of gripper closures, path length, motion efficiency, integrated squared jerk, and a custom questionnaire; analysis used the Friedman test with Bonferroni-corrected Wilcoxon signed-rank pairwise comparisons (α = 0.05/3). The protocol was approved under IRB HIRB00007467.

Why This Matters

The paper reframes hand–instrument coupling in console-free surgical teleoperation as a compensation for poor spatial feedback rather than a fundamental requirement. If rich visual spatial cues from a digital twin can substitute for physical correspondence, interface designers gain freedom to prioritize ergonomics, workspace, and controller stability.

Real-world applications:

  • Portable or console-free surgical teleoperation interfaces that free the surgeon from a stationary console.
  • An auxiliary 3D spatial view added alongside the standard endoscopic feed in conventional dVRK workflows, to resolve occlusion and improve depth understanding.
  • Surgical training and rehearsal, using offline replay with arbitrary multi-view rendering of recorded demonstrations.
  • Collection of synchronized kinematic and spatial demonstration data for imitation learning and robot autonomy, grounded in real physical perception rather than pure simulation.

Industry relevance: The work targets a commercially dominant surgical robotics architecture (the da Vinci lineage, accessed here via the dVRK), uses consumer-grade hardware (Meta Quest 3S) and open pipelines (SAM 2, SAM 3, FoundationPose, sawSocketStreamer), and reports concrete latency numbers that bear on whether such a system could meet clinical real-time requirements.

Future Directions

  • Extending the real-time digital twin beyond rigid bodies to deformable environments such as soft tissue, which the authors identify as a significant computational challenge.
  • Replacing the external RGB-D camera, which is absent from standard clinical setups, with robust stereo-endoscopic depth estimation for clinical translation.
  • Closing the gap between the scene-twin update rate and the 90 Hz robot-twin rate through optimization and hardware acceleration.
  • Deploying the platform as an auxiliary 3D spatial view within the conventional dVRK endoscopic workflow, and using its offline multi-view replay to generate higher-fidelity expert demonstration datasets for deep learning.

Target Audience

Researchers and engineers working on surgical robotics, teleoperation interfaces, and XR-based human–robot interaction, particularly those familiar with the dVRK ecosystem; also relevant to surgical data science groups interested in state-based logging and multi-view demonstration capture, and to HCI researchers studying clutch mechanisms, motion mapping, and depth perception in immersive teleoperation.

Authors’ abstract

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital…

The full abstract on arXiv
Read the original paper