Research
EndoWAM: A Grounded World-Action Model for Generalizable Endoscopic Navigation
Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard.

- arXiv
- 2608.01221 · Preprint · not peer-reviewed
- Published
- 2026-08-02
- Authors
- Jinsong Lin, Zikang Pan, Wanhao Liu, Chi Kit Ng, Liangjing Shao, Zihang Yu, Ziyu Wang, Yin Wang, Jiaxi Wang, Jeremy Yuen-Chun Teoh, Zhiyong Xiong, Huxin Gao, Hongliang Ren
In plain words
Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard. Existing learning-based policies (imitation learning and VLA models) predict actions from the current observation without explicitly modeling how the anatomy will change, which limits reliability in safety-critical surgical settings.
AI summary
Overview
Research area: Surgical robotics / robot learning — specifically world-action models (WAMs) applied to autonomous flexible endoscopic navigation.
Technical level: Advanced. The paper assumes familiarity with diffusion/flow-matching generative models, vision-language-action (VLA) policies, LoRA fine-tuning, and closed-loop physical robot evaluation.
Scope (one sentence): The paper proposes EndoWAM, a world-action model that predicts future target regions from intermediate denoising features of a video world model to drive a three-degree-of-freedom flexible endoscope, and introduces the EndoMotion multi-procedure dataset (515 trajectories, 0.98M frames, expanded to 4,120 sequences and 7.84M frames with viewpoint augmentation) spanning ureteroscopy, esophagoscopy, and ERCP.
What This Paper Is About
Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard. Existing learning-based policies (imitation learning and VLA models) predict actions from the current observation without explicitly modeling how the anatomy will change, which limits reliability in safety-critical surgical settings.
The goal is to build a world-action model tailored to endoscopy: one that predicts future visual dynamics and uses those predictions, plus supervision about where the target will be in future frames, to generate accurate multi-step navigation commands in real time.
Key Contributions
-
EndoWAM, described by the authors as the first World Action Model for generalizable robotic endoscopic navigation. It conditions its action policy on intermediate denoising features of a video world model (initialized from Cosmos-Predict2.5-2B), so predictive visual dynamics are incorporated without paying a decoding cost at deployment.
-
A future grounding paradigm. A diffusion transformer (Grounding DiT) reconstructs the latent target regions of future frames from the shared world-model representation, injecting target-aware supervision into predictive dynamics. This differs from prior grounding methods that localize targets only in the current observation.
-
The EndoMotion dataset. 515 teleoperated trajectories and 0.98M frames across three anatomically distinct procedures (ureteroscopy, esophagoscopy, ERCP), annotated with a fine-tuned Grounding DINO plus Kalman filtering to produce temporally consistent oriented bounding-box tracks, yielding target-relative action labels and future target regions. Rotating trajectories and annotations at 45-degree intervals expands this to 4,120 sequences and 7.84M frames.
-
Controlled grounding variants and real-world evaluation. Three alternative grounding strategies (EndoWAM-EG for explicit input grounding, EndoWAM-CG for regressing future bounding boxes, EndoWAM-FG-Gen for generative grounding) are compared under matched settings on physical phantoms, alongside zero-shot generalization and inference-efficiency studies.
Main Findings
-
State-of-the-art closed-loop success: EndoWAM succeeded in 77 of 96 trials, an average success rate of 80.2%, versus 27.1% for the strongest baseline, GR00T-N1.7 — a 53.1 percentage-point margin. Per procedure it reached 90.6% on ureteroscopy, 56.3% on esophagoscopy, and 93.8% on ERCP.
-
Baselines trail substantially: Diffusion Policy averaged 2.1%, Qwen3DiT 8.3%, π0.5 15.6%, Qwen3AE 17.7%, and GR00T-N1.7 27.1% across the same three procedures.
-
Future grounding beats alternative grounding strategies: EndoWAM's 80.2% average exceeded the strongest variant, EndoWAM-EG (61.5%), by 18.7 points, with gains of 18.7, 12.5, and 25.0 points on ureteroscopy, esophagoscopy, and ERCP respectively. EndoWAM-CG reached 45.8% and EndoWAM-FG-Gen 51.0%.
-
Both design choices are load-bearing: Removing the Grounding DiT drops average success from 80.2% to 37.5%; removing viewpoint augmentation drops it to 28.1%. Attention visualizations show the full model concentrates on the target under darkness and partial occlusion, while the ablated model attends diffusely to specular highlights and mucosal textures.
-
Discrete action head matters: Under an identical Qwen3-VL-2B backbone, Qwen3AE (discrete action expert, 17.7% average) outperforms Qwen3DiT (diffusion action head, 8.3%), supporting the choice of discretized per-axis action bins.
-
Strong zero-shot generalization: Under six unseen conditions, EndoWAM averaged 90.1% versus 46.9% for GR00T-N1.7 (a 43.2-point gap) and 36.5% for Qwen3AE. It hit 100.0% under texture shift, 93.8% under reflectance shift, 87.5% under geometry shift, 84.4% under shape shift, 93.8% under size shift, and 81.3% under color shift.
-
Real-time capable: On a single NVIDIA RTX 5090 with 2.1B parameters, EndoWAM runs at 7.5 Hz — slower than Qwen3AE (12.1 Hz) and GR00T-N1.7 (8.9 Hz) but 6.8 times faster than Cosmos Policy (1.1 Hz), because it predicts an action chunk from features of a single denoising pass rather than iteratively denoising future video.
Methodology in Plain English
The system has three parts sharing one internal representation.
First, a video world model (a diffusion transformer adapted from Cosmos-Predict2.5-2B with LoRA applied to attention and feed-forward projections, while the text encoder and video VAE stay frozen) takes the current endoscopic frame and the language instruction and performs a single denoising pass to predict future latent dynamics. The activation from block 17 of that pass — not the decoded future video — is flattened into a token sequence that serves as the shared representation.
Second, an action decoder takes learnable action queries, mixes them through bidirectional self-attention (so each query sees the whole action chunk) and cross-attention to the shared representation, and outputs categorical logits for each of three motion axes. Actions are therefore discrete bins, not continuous regressions.
Third, a Grounding DiT reconstructs the VAE latents of future target crops conditioned on that same shared representation. Training adds a diffusion loss on those future target latents, masked so frames without a detected target contribute no gradient. The three losses — video flow matching, weighted cross-entropy on actions, and the grounding loss — are summed with balancing weights.
At inference, the world model still does one denoising pass to produce the shared representation, but the future-frame decoding and the Grounding DiT branch are discarded. Future grounding therefore shapes the features during training without adding deployment latency.
Ground truth comes from the EndoMotion dataset: human teleoperation in anatomical phantoms, with a fine-tuned Grounding DINO and Kalman filtering producing oriented bounding-box tracks. Target-center offsets relative to the endoscopic view become discrete action labels, and target crops in future frames become grounding supervision. Rotation augmentation at 45-degree intervals builds viewpoint robustness — and, importantly, all test viewpoints are deliberately offset from the eight augmented roll angles, so every trial measures generalization to an unseen viewpoint.
Evaluation is closed-loop on physical phantoms for all three procedures, 32 trials per procedure, with success defined as reaching the instructed target and keeping it in view until rollout termination; failures are lumen loss, wall impaction, or timeout. Zero-shot tests use a two-stage lumen-traversal-then-localization protocol under six shift conditions.
Why This Matters
Impact on research. Most world-action models target robotic manipulation in rigid, well-lit, largely static scenes. This paper pushes the paradigm into deformable, partially observable, visually degraded anatomy, and shows that where you attach grounding supervision matters — predicting future target regions through latent reconstruction outperforms input-level cropping, bounding-box regression, and generative grounding by wide margins. The controlled variant comparison is a reusable experimental template for anyone asking how to ground a WAM.
Real-world applications (drawn from the procedures studied):
- Ureteroscopy — steering a flexible scope through the ureter toward stones or lesions.
- Endoscopic retrograde cholangiopancreatography (ERCP) — biliary navigation, the highest-scoring procedure here at 93.8%.
- Esophagoscopy — esophageal lumen traversal, which the paper shows is the hardest of the three at 56.3%.
- Viewpoint-robust scope control more generally, since the model transfers to unseen lumen reflectance, geometry, texture, and to unseen target shape, size, and color.
Industry relevance. Surgical robotics companies building semi-autonomous endoscopy need policies that survive specular highlights, occlusion, and camera roll without a data-center-sized inference budget. A 7.5 Hz controller on a single RTX 5090 with a 2.1B-parameter model, where the predictive machinery costs nothing at deployment, is a plausible path toward assistive or supervised-autonomy features. The dataset itself is a contribution industry can build on, given how scarce temporally aligned endoscopic navigation data is.
Future Directions
-
In vivo and clinical validation. All reported evaluation is on physical anatomical phantoms with 32 trials per procedure; the paper reports no animal or human studies, so the gap to real tissue dynamics, bleeding, and respiration-induced motion is unmeasured.
-
Lifting the esophagoscopy gap. 56.3% on esophagoscopy versus 90.6% on ureteroscopy and 93.8% on ERCP suggests procedure-specific failure modes. The paper defers a failure-mode breakdown to its appendix, but the mechanism behind this asymmetry is a clear target for follow-up work.
-
Scaling beyond 515 trajectories. The authors flag data scarcity as a core motivation, and it remains the binding constraint. Whether the future-grounding recipe holds with larger, more viewpoint-diverse corpora, or whether it can leverage unlabeled endoscopic video, is untested here.
-
Extending beyond three degrees of freedom. The current policy controls 3-DoF flexible endoscope motion only. Tool actuation, additional joints, and combined scope-plus-instrument control would demand new action parameterizations; the paper does not report results for these.
Target Audience
Robotics and surgical-robotics researchers working on visuomotor policies, world models, and VLA architectures; graduate students in medical robotics interested in how generative video priors transfer to deformable anatomy; and industry engineers evaluating whether predictive dynamics models are deployable at endoscopic control rates. Readers wanting a first introduction to world-action models should start elsewhere — the paper assumes fluency in diffusion and flow-matching formulations.
Authors’ abstract
Autonomous endoscopic navigation can reduce clinicians' operational burden, yet robust control remains challenging due to tissue deformation, transient occlusions, and rapidly changing viewpoints. Existing learning-based policies typically predict actions from current observations without explicitly modeling future dynamics, limiting their robustness and reliability in safety-critical settings. World Action Models (WAMs) offer a promising alternative by coupling predictive…
The full abstract on arXivRelated papers
- Trajectory Divergence Horizon Decision for Reliable Dual-Arm Surgical Subtask Manipulation 2026-08-10 · cs.RO · Also by Huxin Gao, Jinsong Lin
- EndoVLA-OOV: Language-Conditioned Out-of-View Target Acquisition in Robotic Endoscopy 2026-10-17 · cs.RO · Also by Chi Kit Ng, Huxin Gao
- FlowPilot: Real-Time World-Action Modeling for Agile UAV Navigation 2026-08-01 · cs.RO · Key terms of the title in common
- Memory as Plans: World-Action Modeling with Memory-Grounded Planning 2026-09-10 · cs.RO · Key terms of the title in common
- TacSushi: Tactile-Grounded World-Action Modeling for Dexterous Sushi Manipulation 2026-09-17 · cs.RO · Key terms of the title in common