# EndoWAM: A Grounded World-Action Model for Generalizable Endoscopic Navigation

Robotics.world

> Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard.

**arXiv**: 2608.01221 · Preprint · not peer-reviewed

**Published**: 2026-08-02

**Authors**: Jinsong Lin, Zikang Pan, Wanhao Liu, Chi Kit Ng, Liangjing Shao, Zihang Yu, Ziyu Wang, Yin Wang, Jiaxi Wang, Jeremy Yuen-Chun Teoh, Zhiyong Xiong, Huxin Gao, Hongliang Ren

## In plain words

Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard. Existing learning-based policies (imitation learning and VLA models) predict actions from the current observation without explicitly modeling how the anatomy will change, which limits reliability in safety-critical surgical settings.

## AI summary

## Overview

**Research area:** Surgical robotics / robot learning — specifically world-action models (WAMs) applied to autonomous flexible endoscopic navigation.

**Technical level:** Advanced. The paper assumes familiarity with diffusion/flow-matching generative models, vision-language-action (VLA) policies, LoRA fine-tuning, and closed-loop physical robot evaluation.

**Scope (one sentence):** The paper proposes EndoWAM, a world-action model that predicts future target regions from intermediate denoising features of a video world model to drive a three-degree-of-freedom flexible endoscope, and introduces the EndoMotion multi-procedure dataset (515 trajectories, 0.98M frames, expanded to 4,120 sequences and 7.84M frames with viewpoint augmentation) spanning ureteroscopy, esophagoscopy, and ERCP.

## What This Paper Is About

Autonomous endoscopic navigation could reduce clinicians' workload, but tissue deformation, transient occlusions, and rapidly changing viewpoints make reliable control hard. Existing learning-based policies (imitation learning and VLA models) predict actions from the current observation without explicitly modeling how the anatomy will change, which limits reliability in safety-critical surgical settings.

The goal is to build a world-action model tailored to endoscopy: one that predicts future visual dynamics and uses those predictions, plus supervision about where the target will be in future frames, to generate accurate multi-step navigation commands in real time.

## Key Contributions

1. **EndoWAM**, described by the authors as the first World Action Model for generalizable robotic endoscopic navigation. It conditions its action policy on intermediate denoising features of a video world model (initialized from Cosmos-Predict2.5-2B), so predictive visual dynamics are incorporated without paying a decoding cost at deployment.
2. **A future grounding paradigm.** A diffusion transformer (Grounding DiT) reconstructs the latent target regions of *future* frames from the shared world-model representation, injecting target-aware supervision into predictive dynamics. This differs from prior grounding methods that localize targets only in the current observation.
3. **The EndoMotion dataset.** 515 teleoperated trajectories and 0.98M frames across three anatomically distinct procedures (ureteroscopy, esophagoscopy, ERCP), annotated with a fine-tuned Grounding DINO plus Kalman filtering to produce temporally consistent oriented bounding-box tracks, yielding target-relative action labels and future target regions. Rotating trajectories and annotations at 45-degree intervals expands this to 4,120 sequences and 7.84M frames.
4. **Controlled grounding variants and real-world evaluation.** Three alternative grounding strategies (EndoWAM-EG for explicit input grounding, EndoWAM-CG for regressing future bounding boxes, EndoWAM-FG-Gen for generative grounding) are compared under matched settings on physical phantoms, alongside zero-shot generalization and inference-efficiency studies.

## Main Findings

- **State-of-the-art closed-loop success:** EndoWAM succeeded in 77 of 96 trials, an average success rate of 80.2%, versus 27.1% for the strongest baseline, GR00T-N1.7 — a 53.1 percentage-point margin. Per procedure it reached 90.6% on ureteroscopy, 56.3% on esophagoscopy, and 93.8% on ERCP.
- **Baselines trail substantially:** Diffusion Policy averaged 2.1%, Qwen3DiT 8.3%, π0.5 15.6%, Qwen3AE 17.7%, and GR00T-N1.7 27.1% across the same three procedures.
- **Future grounding beats alternative grounding strategies:** EndoWAM's 80.2% average exceeded the strongest variant, EndoWAM-EG (61.5%), by 18.7 points, with gains of 18.7, 12.5, and 25.0 points on ureteroscopy, esophagoscopy, and ERCP respectively. EndoWAM-CG reached 45.8% and EndoWAM-FG-Gen 51.0%.
- **Both design choices are load-bearing:** Removing the Grounding DiT drops average success from 80.2% to 37.5%; removing viewpoint augmentation drops it to 28.1%. Attention visualizations show the full model concentrates on the target under darkness and partial occlusion, while the ablated model attends diffusely to specular highlights and mucosal textures.
- **Discrete action head matters:** Under an identical Qwen3-VL-2B backbone, Qwen3AE (discrete action expert, 17.7% average) outperforms Qwen3DiT (diffusion action head, 8.3%), supporting the choice of discretized per-axis action bins.
- **Strong zero-shot generalization:** Under six unseen conditions, EndoWAM averaged 90.1% versus 46.9% for GR00T-N1.7 (a 43.2-point gap) and 36.5% for Qwen3AE. It hit 100.0% under texture shift, 93.8% under reflectance shift, 87.5% under geometry shift, 84.4% under shape shift, 93.8% under size shift, and 81.3% under color shift.
- **Real-time capable:** On a single NVIDIA RTX 5090 with 2.1B parameters, EndoWAM runs at 7.5 Hz — slower than Qwen3AE (12.1 Hz) and GR00T-N1.7 (8.9 Hz) but 6.8 times faster than Cosmos Policy (1.1 Hz), because it predicts an action chunk from features of a single denoising pass rather than iteratively denoising future video.

## Methodology in Plain English

The system has three parts sharing one internal representation.

First, a **video world model** (a diffusion transformer adapted from Cosmos-Predict2.5-2B with LoRA applied to attention and feed-forward projections, while the text encoder and video VAE stay frozen) takes the current endoscopic frame and the language instruction and performs a single denoising pass to predict future latent dynamics. The activation from block 17 of that pass — not the decoded future video — is flattened into a token sequence that serves as the shared representation.

Second, an **action decoder** takes learnable action queries, mixes them through bidirectional self-attention (so each query sees the whole action chunk) and cross-attention to the shared representation, and outputs categorical logits for each of three motion axes. Actions are therefore discrete bins, not continuous regressions.

Third, a **Grounding DiT** reconstructs the VAE latents of future target crops conditioned on that same shared representation. Training adds a diffusion loss on those future target latents, masked so frames without a detected target contribute no gradient. The three losses — video flow matching, weighted cross-entropy on actions, and the grounding loss — are summed with balancing weights.

At inference, the world model still does one denoising pass to produce the shared representation, but the future-frame decoding and the Grounding DiT branch are discarded. Future grounding therefore shapes the features during training without adding deployment latency.

Ground truth comes from the EndoMotion dataset: human teleoperation in anatomical phantoms, with a fine-tuned Grounding DINO and Kalman filtering producing oriented bounding-box tracks. Target-center offsets relative to the endoscopic view become discrete action labels, and target crops in future frames become grounding supervision. Rotation augmentation at 45-degree intervals builds viewpoint robustness — and, importantly, all test viewpoints are deliberately offset from the eight augmented roll angles, so every trial measures generalization to an unseen viewpoint.

Evaluation is closed-loop on physical phantoms for all three procedures, 32 trials per procedure, with success defined as reaching the instructed target and keeping it in view until rollout termination; failures are lumen loss, wall impaction, or timeout. Zero-shot tests use a two-stage lumen-traversal-then-localization protocol under six shift conditions.

## Why This Matters

**Impact on research.** Most world-action models target robotic manipulation in rigid, well-lit, largely static scenes. This paper pushes the paradigm into deformable, partially observable, visually degraded anatomy, and shows that where you attach grounding supervision matters — predicting future target regions through latent reconstruction outperforms input-level cropping, bounding-box regression, and generative grounding by wide margins. The controlled variant comparison is a reusable experimental template for anyone asking how to ground a WAM.

**Real-world applications (drawn from the procedures studied):**

- Ureteroscopy — steering a flexible scope through the ureter toward stones or lesions.
- Endoscopic retrograde cholangiopancreatography (ERCP) — biliary navigation, the highest-scoring procedure here at 93.8%.
- Esophagoscopy — esophageal lumen traversal, which the paper shows is the hardest of the three at 56.3%.
- Viewpoint-robust scope control more generally, since the model transfers to unseen lumen reflectance, geometry, texture, and to unseen target shape, size, and color.

**Industry relevance.** Surgical robotics companies building semi-autonomous endoscopy need policies that survive specular highlights, occlusion, and camera roll without a data-center-sized inference budget. A 7.5 Hz controller on a single RTX 5090 with a 2.1B-parameter model, where the predictive machinery costs nothing at deployment, is a plausible path toward assistive or supervised-autonomy features. The dataset itself is a contribution industry can build on, given how scarce temporally aligned endoscopic navigation data is.

## Future Directions

- **In vivo and clinical validation.** All reported evaluation is on physical anatomical phantoms with 32 trials per procedure; the paper reports no animal or human studies, so the gap to real tissue dynamics, bleeding, and respiration-induced motion is unmeasured.
- **Lifting the esophagoscopy gap.** 56.3% on esophagoscopy versus 90.6% on ureteroscopy and 93.8% on ERCP suggests procedure-specific failure modes. The paper defers a failure-mode breakdown to its appendix, but the mechanism behind this asymmetry is a clear target for follow-up work.
- **Scaling beyond 515 trajectories.** The authors flag data scarcity as a core motivation, and it remains the binding constraint. Whether the future-grounding recipe holds with larger, more viewpoint-diverse corpora, or whether it can leverage unlabeled endoscopic video, is untested here.
- **Extending beyond three degrees of freedom.** The current policy controls 3-DoF flexible endoscope motion only. Tool actuation, additional joints, and combined scope-plus-instrument control would demand new action parameterizations; the paper does not report results for these.

## Target Audience

Robotics and surgical-robotics researchers working on visuomotor policies, world models, and VLA architectures; graduate students in medical robotics interested in how generative video priors transfer to deformable anatomy; and industry engineers evaluating whether predictive dynamics models are deployable at endoscopic control rates. Readers wanting a first introduction to world-action models should start elsewhere — the paper assumes fluency in diffusion and flow-matching formulations.

## Authors’ abstract

Autonomous endoscopic navigation can reduce clinicians' operational burden, yet robust control remains challenging due to tissue deformation, transient occlusions, and rapidly changing viewpoints. Existing learning-based policies typically predict actions from current observations without explicitly modeling future dynamics, limiting their robustness and reliability in safety-critical settings. World Action Models (WAMs) offer a promising alternative by coupling predictive…

[The full abstract on arXiv](https://arxiv.org/abs/2608.01221)

[Read the original paper](https://arxiv.org/abs/2608.01221)

## Related papers

- [Trajectory Divergence Horizon Decision for Reliable Dual-Arm Surgical Subtask Manipulation](https://robotics.world/paper/trajectory-divergence-horizon-decision-for-reliable-dual-arm-surgical-2608.09125) 2026-08-10 · cs.RO · Also by Huxin Gao, Jinsong Lin
- [EndoVLA-OOV: Language-Conditioned Out-of-View Target Acquisition in Robotic Endoscopy](https://robotics.world/paper/endovla-oov-language-conditioned-out-of-view-target-acquisition-in-2610.24747) 2026-10-17 · cs.RO · Also by Chi Kit Ng, Huxin Gao
- [FlowPilot: Real-Time World-Action Modeling for Agile UAV Navigation](https://robotics.world/paper/flowpilot-real-time-world-action-modeling-for-agile-uav-navigation-2608.00635) 2026-08-01 · cs.RO · Key terms of the title in common
- [Memory as Plans: World-Action Modeling with Memory-Grounded Planning](https://robotics.world/paper/memory-as-plans-world-action-modeling-with-memory-grounded-planning-2609.11561) 2026-09-10 · cs.RO · Key terms of the title in common
- [TacSushi: Tactile-Grounded World-Action Modeling for Dexterous Sushi Manipulation](https://robotics.world/paper/tacsushi-tactile-grounded-world-action-modeling-for-dexterous-sushi-2609.19613) 2026-09-17 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/endowam-a-grounded-world-action-model-for-generalizable-endoscopic-2608.01221