ForceU-VLA: A Force-Aware Vision-Language-Action Model for Embodied Ultrasound Scanning

Robotic ultrasound scanning must continuously adjust the probe's position, orientation, and contact pressure to capture clinically standard views, but existing embodied systems treat force signals…

The paper’s first page · arXiv:2608.15009
arXiv
2608.15009 · Preprint · not peer-reviewed
Published
2026-08-15
Authors
Xingzheng Wu, Cheng Zhang, Guihao Yan, Xifeng Hu, Zhi Liu, Qing Cai

In plain words

Robotic ultrasound scanning must continuously adjust the probe's position, orientation, and contact pressure to capture clinically standard views, but existing embodied systems treat force signals and ultrasound images as loosely connected inputs and apply the same decision strategy regardless of whether the probe is in free space, approaching the body, or pressing against tissue.

AI summary

Overview

Research area: Robotics — embodied medical intelligence, specifically force-aware Vision–Language–Action (VLA) models for autonomous robotic ultrasound scanning.

Technical level: Advanced. The paper assumes familiarity with VLA architectures, flow-matching action policies, cross-modal attention, and imitation learning for contact-rich manipulation.

Scope: The paper proposes ForceU-VLA, a force-aware VLA model that fuses ultrasound images with six-axis force feedback and modulates that fusion according to the current probe–tissue contact stage, together with a new 450-trajectory real-world ultrasound dataset.

What This Paper Is About

Robotic ultrasound scanning must continuously adjust the probe's position, orientation, and contact pressure to capture clinically standard views, but existing embodied systems treat force signals and ultrasound images as loosely connected inputs and apply the same decision strategy regardless of whether the probe is in free space, approaching the body, or pressing against tissue. The authors' goal is a single model that explicitly couples force and ultrasound perception, and that changes how much it relies on that coupled representation depending on the scanning stage, so that contact stays stable and image quality stays high. They also build the real-world, force-annotated dataset needed to train and evaluate such a model.

Key Contributions

  1. ForceU-VLA, a force-aware VLA framework for autonomous embodied ultrasound scanning that uses force signals and ultrasound image feedback together throughout the scanning process to guide probe motion.

  2. Force-Ultrasound Synergistic Fusion Module (FUSFM), which uses cross-modal attention to let force features modulate ultrasound features and then uses vision–language features to reweight the result, producing a unified representation of local physical interaction and global task semantics.

  3. Stage-Adaptive Modulation Mechanism (SAMM), which maps the Euclidean norm of contact force through a sigmoid to a continuous fusion weight, smoothly shifting the model from vision/language-dominated behaviour before contact to force/ultrasound-dominated behaviour during stable contact, with a learnable force threshold (initialized at 5 N) and learnable transition smoothness (initialized at 2).

  4. ForceU-VLA-Data, a real-world force-aware ultrasound dataset covering two organs (liver and kidney) and five standard clinical views, with 450 expert demonstration trajectories and approximately 100,000 temporally synchronized multimodal samples, collected from 10 subjects performing each task nine times.

Main Findings

  • Highest average success rate: ForceU-VLA achieves 93.3% average success across the five tasks, compared with 43.1% for ForceVLA (a 50.2% improvement) and a 35.1% advantage over the π0 variant incorporating ultrasound, force, and stage-adaptive modeling. On the more challenging Task 3 it surpasses π0.5 by 22.2%.

  • Fewest scanning timesteps: The method averages 351.2 timesteps, reducing average timesteps by 41.3% versus π0, 34.8% versus ForceVLA, and 29.7% versus π0.5. Per-task values range from 243 (Task 5) to 528 (Task 2).

  • Stable force regulation: In Task 2, π0.5 shows large force fluctuations with peaks reaching 30 N, while ForceU-VLA holds contact force at approximately 7.5 N throughout scanning, including during fine adjustments.

  • Ultrasound input matters: Adding ultrasound images to the π0.5 baseline raises average success by 8% and cuts 77 timesteps (72.4% → 80.4% success; 499.6 → 422.6 timesteps).

  • FUSFM adds further gains: Adding the fusion module raises average success by 7.2% and reduces timesteps by 43.6 (80.4% → 87.6%; 422.6 → 379.0).

  • SAMM adds further gains: Adding the stage-adaptive mechanism raises average success by 5.7% and reduces timesteps by 27.8 (87.6% → 93.3%; 379.0 → 351.2).

  • Faster convergence in qualitative comparisons: On Task 1, ForceU-VLA captures richer ultrasound information by 150 timesteps and refines probe position at 200 and 300 timesteps, whereas π0.5 is still performing redundant exploration at 400 timesteps without reaching the standard plane.

  • Robustness to subject position: The model localizes target standard planes whether the subject lies higher or lower, which the authors attribute to dataset diversity and multimodal collaborative modeling.

Methodology in Plain English

The system takes five inputs: a language instruction naming the target view, wrist-view and side-view camera images, the ultrasound image itself, and a six-dimensional force/torque reading from a sensor at the probe.

Each input gets its own encoder. Language is tokenized, the two external camera views go through SigLIP, the ultrasound image goes through a dedicated ultrasound foundation model (USFM) because ultrasound looks nothing like natural images, and the force signal is projected by a linear layer into a 2048-dimensional vector so it matches the visual token dimension.

Fusion happens in two steps. First, the ultrasound features act as queries that attend to the force features, so the model learns how ultrasound appearance changes under different contact modes such as light touch, compression, and sliding. To avoid damaging the pretrained ultrasound representation early in training, that attention block's output projection is zero-initialized. Second, the language-plus-external-view features act as queries over this force-modulated ultrasound representation, selecting the task-relevant parts of the physical interaction. The final projection of the fusion module is also zero-initialized so the module starts as an identity mapping and preserves the pretrained action expert.

The stage-adaptive mechanism computes the magnitude of the contact force and passes it through a sigmoid centred on a learnable threshold. The resulting weight scales how much of the fused force–ultrasound representation is added to the vision–language features before the flow-matching policy predicts its velocity field. The weight therefore moves smoothly from 0.1 in free space to 1.0 under firm contact, rather than switching abruptly. During training, an auxiliary MSE loss pushes this weight toward binary stage labels (0 for no contact, 1 for skin contact) that were manually annotated during data collection, and this loss is combined with the action loss using a balancing coefficient of 0.1.

The dataset was gathered by teleoperation (PIKA system) on a UR7e six-degree-of-freedom arm with two Intel RealSense D435 cameras at 640×480 and 30 FPS, a HISENSE Medical HD60 ultrasound system with an ACASIS VC-X7PRO capture card, and a Robotiq FT 300-S six-axis force sensor. Trajectories were started from eight different directions across three body types (slim, normal, obese) and collected by two experienced sonographers. Models were trained for 30,000 iterations with AdamW at a learning rate of 5×10⁻⁵ and batch size 8 on 8 NVIDIA RTX 3090 GPUs, with data collection and inference both at 15 Hz. Evaluation used 45 independent trials per task, 15 each across the three BMI categories.

Why This Matters

Impact on research: The paper argues that force should not be an auxiliary control variable or a loosely attached extra modality but part of the perception–decision representation itself, and that contact stage is a useful latent structure for multimodal fusion. The continuous, differentiable stage weighting is a reusable idea for any contact-rich VLA task, not just ultrasound, and the dataset gives the community a force-annotated benchmark where previously only visual demonstration data existed.

Real-world applications:

  • Automated acquisition of standard abdominal and renal views to reduce operator dependence in routine examinations.
  • Standardizing scan quality and contact pressure so results are more consistent across operators and sites.
  • Extending scarce sonographer expertise to resource-limited or geographically isolated settings through robotic or teleoperated systems.
  • Safer human–robot physical interaction in examinations, since uncontrolled pressure (peaks of 30 N in a baseline) can cause discomfort and degrade imaging.

Industry relevance: The work targets medical robotics and robot-assisted imaging platforms, where safety, contact stability, and repeatability are purchasing criteria. The authors also note that force-sensor-free variants of force-aware VLA are an active direction (citing FD-VLA), which matters for deployment cost. Code is released at https://github.com/VMVLab/ForceU-VLA, and the work appears in Proceedings of the 34th ACM International Conference on Multimedia (MM '26).

Future Directions

  • Generalization beyond the collected cohort: The dataset covers 10 subjects across three body types and two organs; extending to more anatomies, patient conditions, and pathologies is an open question.
  • Sensor-free force estimation: Given that the method depends on a Robotiq FT 300-S six-axis sensor, distilling the force representation without a physical sensor would substantially reduce deployment cost.
  • Richer stage modeling: The current model uses binary stage labels (no contact versus skin contact) collapsed into a continuous weight; finer-grained stages such as approach, compression, sliding, and release are not separately modeled.
  • Clinical validation: The evaluation measures success rate, timesteps, and force profiles under a fixed protocol of 45 trials per task; diagnostic quality of the acquired planes and performance in real clinical workflows are not reported.

Target Audience

Robotics and embodied-AI researchers working on VLA models, multimodal fusion, and contact-rich manipulation; medical robotics groups building autonomous or teleoperated ultrasound systems; and clinical engineering teams interested in standardizing scan acquisition. Readers without a background in flow-matching policies or cross-attention architectures will find the method sections demanding, though the problem framing and experimental comparisons are accessible.

Authors’ abstract

Embodied intelligent ultrasound scanning enables the automation and standardization of the ultrasound examination process by integrating perception, decision-making, and execution capabilities. However, existing methods suffer from loosely coupled modeling between force and ultrasound modalities and lack awareness of scanning stages, which limits their ability to capture dynamic probe-tissue interactions. To address these issues, we propose ForceU-VLA, a force-aware…

The full abstract on arXiv
Read the original paper