From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

Most minimally invasive surgery is still done by hand with laparoscopic instruments, and when the operation ends the surgeon's instrument motion is discarded — only the endoscope video is kept.

The paper’s first page · arXiv:2609.25625
arXiv
2609.25625 · Preprint · not peer-reviewed
Published
2026-09-22 · revised · 2026-10-20
Authors
Dongho Yee, Juahn Oh, Jinseok Lee, Jiyul Lee, Yechan Seo, Seong Jeong, Minsung Kim, Seonho Shim, Younghoon Noh, Hyuk Choi, Youngbin Kong, Kyu Eun Lee, Hyoun-Joong Kong

In plain words

Most minimally invasive surgery is still done by hand with laparoscopic instruments, and when the operation ends the surgeon's instrument motion is discarded — only the endoscope video is kept. On a teleoperated robot like the da Vinci that motion is recorded automatically, which is why surgical imitation learning has depended on robot-collected demonstrations that are small and tied to one platform.

AI summary

Overview

Research area: Surgical robotics and robot learning from demonstration — specifically imitation learning for bimanual minimally invasive surgery, spanning custom sensor hardware, sensor-fusion and latency calibration, diffusion-policy design, physics-simulation-based configuration selection, and live-animal validation.

Technical level: Advanced. The paper assumes familiarity with diffusion policies, vision transformer backbones, action chunking, remote-center-of-motion kinematics, and closed-loop sim-to-real evaluation protocols. The clinical motivation and headline result are accessible to a general reader, but the methodological core is aimed at robotics researchers.

Scope (1 sentence): The paper shows that motion captured from a surgeon's own hand-held laparoscopic instruments — not from a robot — is sufficient to train, select, and deploy a bimanual surgical robot policy that performed laparoscopic appendectomy with electrosurgery in three of four live rabbits.

What This Paper Is About

Most minimally invasive surgery is still done by hand with laparoscopic instruments, and when the operation ends the surgeon's instrument motion is discarded — only the endoscope video is kept. On a teleoperated robot like the da Vinci that motion is recorded automatically, which is why surgical imitation learning has depended on robot-collected demonstrations that are small and tied to one platform. This paper asks whether the discarded signal of hand-held surgery can be captured in the operating room with a small shaft-mounted sensor and turned into a robot policy, and it answers that question end to end for laparoscopic appendectomy, up to and including energized tissue division in live animals.

Key Contributions

  1. A surgical instrument-state logger. An operating-room-ready device mounted on the shaft of a standard laparoscopic instrument that recovers the full instrument state — roll, depression, insertion depth and jaw opening — from an inertial measurement unit, a time-of-flight sensor and a Hall sensor, under the trocar's remote-center-of-motion constraint, with no external camera or tracker. It is paired with a processing chain built on per-channel latency matching against a robot ground truth; the matching halves the dynamic depth error and, when ablated in closed loop, proves necessary for the lift stage (81% vs. 19%).

  2. A policy configuration chosen by closed-loop evidence rather than offline error. Instead of picking the policy design by validation loss, the authors compare 31 candidate configurations (backbone, unfreezing depth, phase input, latency matching, replanning) in closed-loop rollouts in a physics simulator reconstructed from depth recordings of the ex-vivo scene, score them by stage counts and exact tests, and run only the winner on a two-FR3 rig.

  3. In-vivo execution on live animals. The configuration retrained from scratch on 849 in-vivo demonstrations completed the appendectomy in three of four live rabbits under shared autonomy with electrosurgery armed — described by the authors as, to their knowledge, the first time a learned policy has fired electrosurgery in vivo.

  4. Released demonstration corpora. Both the ex-vivo (533 episodes, 74 min) and in-vivo (849 episodes, 135 min) corpora are released to support future surgical robot learning research.

The robot serves only as the timing reference for sensor calibration and as the executor; it collects no demonstrations.

Main Findings

  • Sensor accuracy beats video-based tracking by a wide margin. Against the FR3 tip pose during free motion, the latency-matched logger tracks shaft roll and depression to 0.42° and 0.17° RMS and insertion depth to 1.36 mm RMS once the firmware's fixed gain and offset are calibrated out (5.6 mm before). Tip displacement over a 1.6 s action chunk is 1.38 mm RMS (2.89 mm at the 95th percentile). On the same rig, a markerless fit of the shaft's silhouette edges located the shaft axis only to a median 10.7 mm.

  • Latency is heterogeneous across channels and must be corrected per channel. On the ex-vivo logger, attitude channels showed pure transport delays of 24–26 ms, insertion depth showed L+T = 349 ms (93% of it first-order lag from the firmware's exponential moving average, gain falling to 0.42 at 1 Hz), and the jaw channel 79 ms (endoscope 42 ms). The resulting 325 ms depth–attitude skew is 3.5 policy steps at 10 Hz, so no common time shift can remove it. Rewinding each channel by its own latency cut dynamic depth error from 2.69 to 1.36 mm (−49.5%) and shaft-roll error by 28%; the depression channel, a control, changed by only +2%.

  • Latency matching is necessary for manipulation, not just for accuracy. Training the deployed configuration without per-channel latency matching left trocar violations unchanged (19% vs. 19%) but eliminated successful lifts (19% vs. 81%, p=0.001) — while its offline validation error was better (0.138 vs. 0.148). The skew breaks the coordinated insertion that lifting requires, something offline error cannot see.

  • A frozen self-supervised vision backbone dramatically improves safety. Replacing the two ResNet-18 encoders with a frozen DINOv3 ViT-B/16 reduced trocar violations from 88% to 6% (Fisher p=7×10⁻⁶) and raised lift from 12% to 69% (p=0.003).

  • Unfreezing exactly one transformer block is the sweet spot. The selection criterion was full approach without a violation (lift, arrive at site, close jaw on tissue). One unfrozen block reached 81%, versus 50% for two blocks and 44% for the fully frozen backbone; safety degrades as more blocks are unfrozen (violations 6%, 19%, 19%, 56%, 69% for zero to four blocks, p=6×10⁻⁴ for four vs. frozen).

  • Offline action error is anti-correlated with closed-loop safety. Across the unfreezing sweep, validation MAE improves monotonically (0.152 → 0.142) while violations rise from 6% to 69%. The least safe encoder, ResNet-18, has a better MAE (0.145) than the frozen DINOv3 (0.152). GR00T-H, the vision-language-action baseline, reached 0% full approach (none of 24 checkpoints closed a jaw on tissue) with MAE 0.184.

  • A vision-based phase predictor collapsed at deployment. A predictor trained on demonstration video cut the deployed configuration's lift from 81% to 31% (p=0.01) and full approach from 81% to 25% (p=0.004); on the real rig it saturated at the final phase within a median of 10.6 s, and in vivo it agreed with the surgeon on only 24.6% of policy control steps. The surgeon therefore supplied the surgical phase by keypress.

  • Replanning matters as much as the phase input. Committing one action per chunk instead of three raised violations from 19% to 69% and cut full approach from 81% to 31% (p=0.01).

  • Ex-vivo pre-training did not change a single in-vivo decision. Training in-vivo from random initialization versus from the deployed ex-vivo weights passed the same pre-registered gates in all six runs at 25%, 50% and 100% of the in-vivo corpus; pre-training helped only while data were scarce (MAE 1.221 vs. 1.413 at 25%, 1.176 vs. 1.173 at 50%, 1.157 vs. 1.173 at 100%).

  • Three of four live rabbits had a completed appendectomy. In a single day, four live rabbits were run at 5 Hz with electrosurgery armed: policy control times were 34.2 s, 16.8 s and 14.7 s, with cautery fired by the policy for 4.6 s, 3.0 s and 3.2 s and peak RCM errors of 0.20 mm, 0.21 mm and 0.84 mm. In each success a single rollout carried the instruments from grasp approach to the energized cut without the surgeon touching them. The fourth animal was aborted at hand-over by a joint-limit governor in a poorly conditioned inverse-kinematics branch (controller, not policy) and completed by hand. All four animals survived and showed no gross abnormality over one week of post-operative observation.

  • Safety margins held throughout. RCM error never exceeded 0.84 mm against a 5 mm abort threshold during policy control; every sample exceeding that threshold in the day's logs occurred under human teleoperation. In all 108 cautery samples under policy control (10.8 s at 10 Hz) the cutting jaw was closed (aperture at most 0.7%).

  • Inference was fast relative to the control loop. On one workstation with an NVIDIA RTX 4090 (DINOv3 in fp16), median 23.5 ms per step and 95th percentile 59.7 ms, well inside the 200 ms control period.

  • On the real ex-vivo rig the selected configuration was clean. 15 sessions and roughly 18 min of policy control on a rabbit cadaver produced zero trocar violations and a peak RCM error of 0.23 mm.

Methodology in Plain English

The authors start from the observation that a rigid instrument passing through a trocar has only four degrees of freedom, not six, because the trocar pivot removes two. That makes the sensing problem small enough for a tiny board on the instrument shaft: an inertial sensor supplies gravity-referenced orientation, a time-of-flight sensor pointed down the shaft measures how far the instrument has been inserted, and a Hall sensor on the handle reads a magnet to measure jaw opening. Two versions were built — a cable-powered ex-vivo unit and a battery-powered, Bluetooth-streaming in-vivo unit housed in a compact enclosure with no exposed wiring that runs roughly 20 h at about 50 mA, beyond one operating-room day.

The subtle problem is timing. Each sensor channel arrives late by a different amount, and the endoscope camera has its own delay. The authors had a Franka FR3 drive the instrument along known trajectories while its tip pose served as ground truth, fitted a delay-plus-first-order-lag model to each channel, and then rewound each stream by its own measured latency before resampling everything onto the endoscope clock. Notably, insertion depth was not merely delayed — part of its motion was smoothed away by firmware filtering, so it had to be corrected rather than just shifted.

Because a cheap magnetometer's heading drifts in an operating room, the observations use only what gravity and the trocar define: the endoscope image plus, per arm, shaft roll, depression and normalized insertion depth. Jaw aperture is deliberately excluded as an input (with it, the policy learns "it is closed, so keep closing"), and the heading drift is negligible within a single 1.6 s chunk, so actions are expressed as tip-frame deltas relative to each chunk's anchor pose. That makes every label invariant to the heading zero and to the trocar location, so no correspondence between the demonstration trocar and the robot's trocar is needed.

For policy design, the authors built a simulator in Isaac Sim with six finite-element organs reconstructed from depth maps of the phantom, nominal soft-tissue stiffness, and cameras at the poses measured on the real rig. They ran 16 episodes of 15 s per candidate across 31 configurations, scored stage counts and a single hard failure (a trocar violation, defined as RCM error above 10 mm), and used Fisher's exact test to compare. The selection criterion was deliberately "full approach without a violation," because a policy that does nothing never violates the trocar. Only the winner was then run on the real two-FR3 rig, and it became the configuration retrained from scratch on the in-vivo corpus, with checkpoints accepted through pre-registered event-level gates on the last 5% of episodes in recording order rather than by offline error.

At deployment the surgeon placed the instruments, checked the hand-over state, handed control to the policy, supplied the surgical phase by keypress, and could take control back at any moment. A chunk executor replanned every three actions at 5 Hz, with the chunk's start index tuned to absorb observation, inference and arm latency, and electrosurgery had to pass five gates before firing.

Why This Matters

Impact on research. The paper reframes where surgical demonstration data can come from. Instead of the robot being the data source, the robot becomes a timing reference and an executor, and the data come from the surgeon's ordinary instruments in the actual operating room. It also delivers a methodological caution that generalizes well beyond surgery: offline validation error was not merely uninformative about closed-loop performance, it was anti-correlated with safety, so policy design decisions made on validation loss would have selected the least safe encoder. The released corpora give the field a demonstration set that no robot collected.

Real-world applications (potential):

  • Scaling surgical imitation-learning datasets by recording routine hand-held laparoscopy in ordinary operating rooms, without buying robot time or instrumenting the surgeon.
  • Skill assessment and training feedback from objective instrument kinematics, since the logger already reconstructs roll, depression, insertion depth and jaw state per case.
  • Semi-autonomous assistance for specific subtasks (retraction, exposure, approach, suturing steps) under shared autonomy with a surgeon able to take over at any moment, on general-purpose arms with standard instruments rather than a single closed platform.
  • Retrospective analysis of instrument motion tied to outcomes across large case volumes, since the hardware is cheap and does not enter the patient.

Industry relevance. The result targets the 75.8% of minimally invasive abdominal operations still done laparoscopically rather than robotically (vs. 24.2%, in a US national inpatient sample of 2012–2019 admissions), against a backdrop of roughly 3.15 million da Vinci procedures worldwide in 2025. An aftermarket sensor that converts existing laparoscopic practice into robot-training data, and policies that run on general-purpose arms such as the FR3 rather than a proprietary console, opens a route to surgical assistance that does not require replacing the installed base of laparoscopic instruments or the surgeon's workflow.

Future Directions

  • Fixing phase recognition under domain shift. The surgeon had to supply the surgical phase because the vision-based predictor agreed with them on only 24.6% of policy control steps under the deployment endoscope, and on the rig it saturated at the final phase within a median of 10.6 s. Closing that gap is the most direct path from shared autonomy toward the full autonomy the authors explicitly do not claim.

  • Broadening the evidence beyond one day and eight animals. The in-vivo study used demonstrations from four rabbits and one deployment in each of four others, all on a single day. Whether the policy transfers across surgeons, anatomy, tissue condition and OR setups is untested.

  • Testing whether the pre-training result holds at larger data scales. Ex-vivo pre-training was neutral at 50% and 100% of the in-vivo corpus and helpful only at 25%, which the authors read as evidence that a live-tissue policy must be trained on live-tissue demonstrations. Whether that holds with much larger corpora, or with other pre-training sources, is open.

  • Extending the logger beyond four degrees of freedom and beyond appendectomy. The current design exploits the RCM constraint and reads jaw opening with a single Hall sensor; whether the same instrument-mounted paradigm scales to articulated or wristed instruments, to more complex procedures, and to the articulated tools where the four-DOF assumption no longer holds is unresolved.

Target Audience

Robotics and machine learning researchers working on imitation learning, visuomotor policies and sim-to-real transfer will get the most from this paper, particularly those interested in robot-free demonstration collection and in why offline error misleads. It is equally relevant to surgical robotics groups and translational clinicians evaluating what it takes to move a learned policy into live-animal and eventually human procedures, and to medical-device and surgical-instrument companies assessing low-cost sensing for skill assessment or autonomy. Readers without a robotics background can follow the problem framing, the clinical motivation and the in-vivo results, but the ablation tables and policy-design discussion assume fluency with diffusion policies and closed-loop evaluation.

Authors’ abstract

Most minimally invasive surgery is still performed with hand-held laparoscopic instruments, and the surgeon's instrument kinematics are lost when the operation ends; only the endoscope video is kept. This paper presents an end-to-end pipeline that captures this motion in the operating room and uses it to train a surgical robot policy, validated on live animals. We introduce a surgical instrument-state logger that mounts on the shaft of a standard laparoscopic instrument and…