Skip to content
Robotics.world

Research

Laser-Tracker-Assisted Camera-to-Robot Calibration for Mobile Robots

Conventional hand–eye calibration assumes a robot can move through sufficiently diverse poses to uniquely determine the rigid transform between a camera and the robot body.

The paper’s first page · arXiv:2609.27006
arXiv
2609.27006 · Preprint · not peer-reviewed
Published
2026-09-22
Authors
Jan A. Rudolph, Öykü Kandemir, Markus Ulrich

In plain words

Conventional hand–eye calibration assumes a robot can move through sufficiently diverse poses to uniquely determine the rigid transform between a camera and the robot body. Mobile robots such as RITA move approximately on a planar factory floor, so their motion does not constrain all components of that transform, and the laser tracker cannot see the camera coordinate system directly.

AI summary

Overview

  • Research area: Robotics metrology — hand–eye (camera-to-robot) calibration for camera-equipped mobile robots, combining laser-tracker 3D metrology with camera-based 2D target observations.
  • Technical level: Intermediate (the paper uses homogeneous transformations and line-of-sight error metrics, but the procedure itself is described step by step and is readable for engineers familiar with basic calibration concepts).
  • Scope: The paper generalizes the authors' earlier laser-tracker-assisted camera-to-robot calibration method — which only worked for ground-observing (nadir) cameras on the mobile robot RITA — into a chained-target workflow that supports cameras mounted in arbitrary orientations, and evaluates its precision and absolute accuracy on a real robot.

What This Paper Is About

Conventional hand–eye calibration assumes a robot can move through sufficiently diverse poses to uniquely determine the rigid transform between a camera and the robot body. Mobile robots such as RITA move approximately on a planar factory floor, so their motion does not constrain all components of that transform, and the laser tracker cannot see the camera coordinate system directly. The authors solve this by using a laser tracker as an external metric reference and linking it to a camera-observable calibration plate through a chain of calibration targets, so the camera pose relative to the robot can be recovered even when the camera does not look straight down.

Key Contributions

  1. A generalized laser-tracker-assisted camera-to-robot calibration formulation that removes the previous method's restriction to a nadir (ground-observing) camera and supports cameras at arbitrary orientations, including a front-looking camera.
  2. A chained target-registration procedure: an auxiliary camera images pairs of adjacent calibration plates (each image containing two targets), and the relative poses are composed into a single transform from the reference plate to the plate the robot's camera observes — eliminating the need for a dedicated combined drive-on plate.
  3. A calibration-object decoupling: the reference plate carrying the three reflector nests (red, green, blue) is separated from the plate observed by the robot, so the observed plate can be placed wherever the robot camera can see it, and the resulting calibration object can be reused to calibrate a series of robots.
  4. An experimental evaluation on the real mobile robot RITA reporting both precision (repeatability across eight calibrations) and, for the first time in this line of work, absolute accuracy against laser-tracker ground truth using point-to-line-of-sight distance and reprojection error.

Main Findings

  • Scene A (short chain, n = 2) is precise: with one intermediate calibration plate, a reference-to-observed-plate distance of about 0.9 m, and two chain images, the RMS deviation of the camera-to-robot transform over N = 4 calibration runs was 2.449 mm and 0.124°, with a maximum pairwise difference of 6.041 mm and 0.288°.
  • Scene B (long chain, n = 3) is less precise: with the reference plate rotated by approximately 180° about the vertical axis, two intermediate plates, a distance of about 1.3 m, and three chain images, the RMS deviation over N = 4 runs was 5.216 mm and 0.360°, with a maximum pairwise difference of 12.457 mm and 0.717°.
  • Depth is the weak direction: the precision in z (the camera's viewing direction) is worse than in the lateral direction.
  • Chain length drives error: the lower precision of Scene B is attributed to the larger reference-to-observed plate distance, which forced an additional intermediate target pose; the authors state the chain length should be minimized to avoid error accumulation.
  • Scene A accuracy is sub-centimeter: across 120 evaluations (30 robot poses × 4 calibrations), the mean orthogonal point-to-line-of-sight distance was 0.580 cm (RMS 0.615 cm, max 0.961 cm), and the mean reprojection error was 16.098 px (RMS 17.265 px, max 29.561 px).
  • Scene B accuracy shows systematic error: across the same 120-evaluation protocol, the mean point-to-line distance was 2.331 cm (RMS 2.405 cm, max 3.824 cm) and the mean reprojection error was 64.190 px (RMS 66.708 px, max 116.794 px); the error plots show Scene A results scattered around ground truth while Scene B results carry a significant systematic offset.
  • Absolute accuracy became measurable: because the outward-facing camera observes a larger workspace and can measure reference points with the laser tracker, the authors could evaluate absolute accuracy, which was not possible with the previous printed-floor-mark verification that only supported precision assessment.

Methodology in Plain English

The workflow has two stages.

First, build a "calibration object." A reference plate carries three circular reflector nests whose 3D positions relative to the plate are known from a stereo measurement (including the offset to the inserted reflector centers); its pose in the tracker coordinate system is obtained by having the laser tracker measure the three reflector centers and matching them to the known plate coordinates. Because the robot's camera may not see that reference plate, an auxiliary camera takes a series of images, each containing two adjacent HALCON calibration targets. Composition of the two detected target poses in each image gives the relative pose of neighboring plates, and multiplying these along the chain yields the pose of the plate the robot will observe relative to the reference plate. If both plates fit in one image, a single auxiliary image suffices.

Second, calibrate the robot. The robot's camera images the far end of the chain, giving the camera-to-plate pose. The robot pose in the tracker frame comes from the tracker-measured position of the reflector mounted on the robot plus inertial orientation, with zero roll and pitch assumed because motion is planar; alternatively the rotation part follows the authors' earlier formulation. Composing camera-to-plate, plate-to-reference-plate, reference-plate-to-tracker and tracker-to-robot yields the camera-to-robot transform.

For evaluation, precision was measured by repeating the whole procedure four times in each of two scenes and comparing the resulting transforms against their mean. Accuracy was measured by moving the robot to 30 poses, imaging a laser-tracker-measured reference point from each pose, and computing both the perpendicular distance from the ground-truth 3D point to the camera's line of sight and the reprojection error in pixels.

Why This Matters

This work makes high-accuracy camera-to-robot calibration feasible for mobile robots whose planar motion breaks standard hand–eye solvers, and it does so without a special-purpose combined plate or vertical robot motion — a practical constraint that the SCARA-style workaround of moving the tool to a predefined height could not satisfy here. It also gives the community a rare absolute-accuracy assessment for this class of method, not just a repeatability number.

Real-world applications:

  • In-situ 3D measurement and positioning in large indoor industrial facilities, the stated use case for RITA.
  • Factory-floor metrology where a mobile platform carries a high-resolution camera and must report coordinates in an external, tracker-defined reference frame.
  • Inspection and assembly tasks that require a mobile robot's camera measurements to be traceable to a laser-tracker datum.
  • Rapid recalibration or initial calibration of fleets of camera-equipped mobile robots using one reusable calibration object.

Industry relevance: the method bridges geodetic metrology hardware (a Leica Absolute Tracker AT901 with a 1.5-inch corner-cube reflector) and machine-vision calibration tooling (HALCON targets, industrial IDS cameras), which matches how large-part manufacturing and aerospace/automotive assembly cells are already instrumented.

Future Directions

  • Isolating and quantifying individual error contributions: translation and orientation components of the robot poses, the calibration target poses, and the stability of the setup.
  • Using that error analysis to optimize calibration target arrangements and the methodology itself, with the aim of further improving accuracy and precision.
  • Reducing chain length and reference-to-observed plate distance systematically, since these were identified as the drivers of the Scene B degradation and its systematic offset.
  • Determining how far the approach generalizes across other camera-equipped mobile robot systems beyond RITA, which the paper motivates but evaluates on a single platform.

Target Audience

Robotics and machine-vision engineers who need to calibrate cameras on mobile or planar-motion platforms; metrology researchers working with laser trackers and photogrammetric target registration; and industrial practitioners deploying mobile robots for measurement tasks in large indoor facilities. Readers primarily interested in manipulator kinematics or SCARA-specific hand–eye theory will find less here, as the authors explicitly position the work as a practical calibration procedure rather than a kinematic analysis.

Authors’ abstract

We present a laser-tracker-assisted hand-eye calibration method for camera-equipped mobile robots. The method combines laser-tracker-based 3D metrology with camera-based 2D observations. Building on our previous laser-tracker-assisted camera-to-robot calibration method for ground-observing mobile robots, we present a generalized formulation for calibrating the camera pose in the coordinate system of tracker-localized mobile robots. The new approach relaxes assumptions of our…

The full abstract on arXiv
Read the original paper

Related papers