# Magnetic based In-situ Self 3D Pose Estimation for a Modular Soft Tendon-Driven Continuum Robot via IMU-Fusion

Robotics.world

> Continuum robots bend continuously, so knowing their shape is hard — kinematic models drift under friction, hysteresis and contact, and external cameras fail when the robot is occluded (for example…

**arXiv**: 2609.39950 · Preprint · not peer-reviewed

**Published**: 2026-09-30

**Authors**: Zheng Cao, Guo Ning Sue, Xiangyun Bu, David Quinn, Junzhe Hu, Carmel Majidi

## In plain words

Continuum robots bend continuously, so knowing their shape is hard — kinematic models drift under friction, hysteresis and contact, and external cameras fail when the robot is occluded (for example, inside a shirt it is grasping).

## AI summary

## Overview

**Research area:** Soft robotics — embedded proprioception and 3D shape/pose estimation for modular tendon-driven continuum robots, combining magnetometer sensing with inertial measurement units (IMUs).

**Technical level:** Advanced. The paper assumes familiarity with continuum-robot kinematics, sensor fusion (error-state Kalman-style bias estimation), magnetic field sensing, and neural network regression.

**Scope:** The paper presents and experimentally validates an embedded magnetic–inertial sensing architecture that reconstructs the 3D backbone of a nine-module soft continuum robot at 16.7 Hz without external cameras, and uses that estimate for closed-loop tip-height control.

## What This Paper Is About

Continuum robots bend continuously, so knowing their shape is hard — kinematic models drift under friction, hysteresis and contact, and external cameras fail when the robot is occluded (for example, inside a shirt it is grasping). The authors build sensing electronics directly into each 20 mm robot module — a small planar coil that generates a magnetic field and a magnetometer-plus-IMU board that reads it — and learn the mapping from measured magnetic field to the bend direction of each joint. Fusing these intermittent magnetic fixes with continuously polled IMU attitude estimates lets the robot compute its own 3D shape in real time and hold its tip at a commanded height even after a 500 g load is attached.

## Key Contributions

1. **A modular magnetic–inertial sensing architecture** for embedded three-dimensional shape reconstruction, in which each mechanical module carries its own PCB coil, magnetometer, IMU and microcontroller, so modules can be stacked and swapped (the paper demonstrates operation with both 9 and 8 modules).
2. **A sensing and communication scheme achieving 16.7 Hz configuration updates**, an improvement over the approximately 1.2 Hz estimation rate of the prior magnetic system the authors build on ([13]), by interleaving continuous attitude polling with short, scheduled magnetic bursts.
3. **A shared learned joint model** — an MLP trained on approximately 15,000 unique poses collected over 10 h — that maps normalized magnetic field change to a joint direction, plus per-segment calibration and quaternion–magnetic fusion.
4. **Experimental validation** across four pose-estimation scenarios (20 trials), an open-loop cloth-grasping demonstration under occlusion, and closed-loop tip-height control with a 500 g disturbance.

## Main Findings

- **Overall accuracy:** Fusion achieved pooled backbone and tip RMSEs of 10.0 ± 3.2 mm and 14.9 ± 6.5 mm across all 20 trials. Mean tip RMSE corresponds to 5.5% of the approximately 270 mm robot length, with link angular RMSE of 9.3°.
- **Per-scenario accuracy:** Planar curl gave 7.6 mm backbone and 8.8 mm tip RMSE (6.3° angular); planar curl with obstacle 11.3 mm and 16.5 mm (9.7°); free 3D curl 13.3 mm and 21.1 mm; manual 3D manipulation 7.8 mm and 13.0 mm.
- **Fusion beats either sensing mode alone:** Magnetics-only averaged 24.6 mm backbone and 42.3 mm tip RMSE; constrained acceleration plus quaternions 114.8 mm and 176.2 mm; acceleration only 175.3 mm and 274.7 mm. The inertial variants saturated in every trial, with errors of 100–300 mm developing within 1 s.
- **Magnetic-only angular accuracy at coil activation:** 5.4° median, 9.7° RMS, and 17.8° at the 95th percentile; in free 3D curling these degraded to 7.4° median and 31.7° at the 95th percentile.
- **Closed-loop tip-height control worked:** Using 8 modules (9 including the base), fused feedback at 18.6 Hz regulated tip height to 40 mm, reaching the target in 3.4 s, peaking at 46 mm (15% overshoot), and settling within ±2 mm after 5.5 s; it then held 40.6 ± 0.04 mm for 10 s.
- **Disturbance recovery:** A 500 g load applied at 24 s lowered the tip and shifted bending from distal to proximal joints; height recovered to within 2 mm of target 5.1 s after its minimum and then held 39.0 ± 0.3 mm.
- **Occlusion robustness:** During stationary intervals of 7, 20 and 14 s in the cloth-grasping task, tip estimates varied by at most 6 mm with fusion, versus 40 mm for magnetics-only and 50–280 mm for the inertial variants (a stability measure, not absolute accuracy).
- **Drift behaviour:** In a 31.9 min static hold (all gyroscopes below 0.02 rad/s, 5258 magnetic fixes), fused and magnetics-only tip displacements reached 11.1 and 12.7 mm, with linear-trend displacements of 8.7 and 8.4 mm and RMS scatter of 0.6 and 1.3 mm.
- **Cyclic actuation trade-off:** Over 49 analyzed cycles of 50 pull–release cycles, fusion showed a baseline change of 16.1 mm and cycle-to-cycle variation of 2.3 mm, versus 4.4 mm and 7.9 mm for magnetics-only — magnetic sensing had less baseline change but greater variability, and the final phase-matched tip difference reached 29.1 mm for fusion.
- **Fusion helps less over short trials:** Magnetic corrections offered little benefit during the 13–30 s trials, because magnetic fixes arrive every approximately 3 s per joint while attitude heading drift is only about 0.65% of angular travel.
- **Model variants barely matter:** Five training and architecture variants differed by less than 0.4 mm in fused backbone RMSE and 0.2° in magnetic angular error; receiver alignment mattered more, and omitting it increased error.
- **Fixed-pivot assumption supported:** A fitted spherical surface over the sampled workspace gave an RMSE of 0.19 mm.
- **Context versus prior work:** The authors contrast their 14.9 mm (5.5% of length) tip error with 47.4 mm (7.3%) for the 650 mm coil-based system of Sue et al. [13] and note it exceeds the 2.9% reported for bend-sensor–IMU fusion (Han et al. [29]); they also report the discussion's figure of 14.5 mm (5.4% of length), with 3.3% during planar curling and 5–8% in 3D.

## Methodology in Plain English

Each robot module is a 3D-printed (TPU 90A) unit 20 mm high, with two 50 mm disks joined by a 16 mm hourglass joint. Every module carries a circuit board with an IMU, a microcontroller, a switching transistor, and a flat spiral coil. Because each module has its own coil rather than a single magnet at the base, arbitrarily many modules can be stacked.

The coils are wound as copper traces on both sides of a 0.8 mm PCB, deliberately asymmetric in shape so the magnetic field has identifiable features rather than being perfectly symmetric. A 40 ms, 3.3 V pulse produces about 100 μT at the neighbouring segment, against roughly 0.6 μT of noise per axis — a large, easily measured signal.

The model of each joint is deliberately simple: the joint behaves like a fixed-radius spherical pivot with no twist, so all the estimator needs is the direction (a unit vector) pointing from one module to the next. The team collected training data by using two webcams and AprilTags to steer a single joint toward randomly sampled orientations across the reachable workspace, then learned a small neural network mapping the normalized magnetic field change to that direction. Training labels came from gravity (normalized accelerometer readings with the base levelled), which avoids camera and pivot-fitting error. The normalization removes variation in field amplitude.

During operation the system alternates between two modes. Most of the time it polls IMU attitude from all segments — a ten-segment sweep takes about 52 ms, giving 16.7 Hz. Every 300 ms one coil fires for 40 ms while the other segments' small magnetometer blocks are read (about 3 ms each). The IMU's rotation vector does not use magnetic input, so it keeps working during coil firing; the magnetic measurements then correct its arbitrary initial heading and slow drift through a per-segment bias state updated in a Kalman-style filter. The 3D backbone is reconstructed by walking out from the base, adding a fixed 29 mm segment length in each estimated direction — no acceleration integration is required, which is what prevents the runaway errors seen in the inertial-only baselines.

For control, the authors note that tip height is computable from the estimated segment directions alone and is insensitive to heading error, making it a clean test of the height feedback loop rather than of drift correction. A proportional–integral–derivative law on spool velocity drives the tendon, with conditional integration to limit windup and no unwinding past neutral.

## Why This Matters

**Impact on research:** The work shows a route to real-time, camera-free proprioception for soft robots that scales with module count — the previous magnetic approach ran at approximately 1.2 Hz and used a single base magnet, which limits both dynamics and stack length. Achieving 16.7 Hz makes shape feedback fast enough for closed-loop control, and the careful error decomposition (reference floor, occlusion frames, alignment sensitivity) gives the field a template for honest benchmarking of soft-robot shape sensing.

**Real-world applications:**

- Minimally invasive surgical or endoscopic tools, where the robot is inside the body and cameras cannot see it.
- Delicate grasping and food harvesting, where the target object itself occludes the robot (the paper's shirt-grasping demo is exactly this case).
- Inspection and manipulation in cluttered or opaque environments such as confined spaces or rubble.
- Reconfigurable robotic arms whose length is changed in the field, since the sensing is per-module and the same trained joint model is reused.

**Industry relevance:** The hardware is cheap and manufacturable — PCB coils fabricated on standard FR4 with 2 oz copper, commodity IMUs and microcontrollers, an ESP32-S3 and a Raspberry Pi 5 running ROS 2. That combination is attractive to companies building soft grippers, surgical devices and human-safe manipulators, because it replaces external motion-capture infrastructure with onboard sensing. The demonstrated modularity (operation with 8 versus 9 modules) is directly relevant to product lines where arm length is a configurable option.

## Future Directions

- **Better drift correction.** Fused and magnetics-only estimates both drifted by roughly 8–9 mm over the 32 min hold, and fusion's baseline change in cyclic testing (16.1 mm) was larger than magnetics-only (4.4 mm), suggesting filter retuning or joint-specific bias modelling.
- **Expanding the training workspace.** Free 3D curling exceeded the training cap of 25°–30° with bends of 20°–40°, producing the largest errors (13.3 mm backbone, 21.1 mm tip), so broader training coverage is an open need.
- **Extending feedback from tip height to full backbone shape.** The demonstrated controller only regulates a heading-insensitive scalar; shape control and independent verification of control accuracy are both unresolved.
- **Adding force sensing and validating long-term drift against independent ground truth**, so that creep can be separated from estimator drift — something the authors explicitly say the current data cannot do.

## Target Audience

Robotics researchers and graduate students working on soft and continuum robots, proprioception, or sensor fusion; engineers designing surgical, inspection or food-handling robots that must operate without line-of-sight to a camera; and practitioners interested in low-cost distributed embedded sensing. Readers wanting the core idea can read the abstract and Section V; the estimation and calibration details in Section III assume background in quaternion algebra, magnetic field modelling and state estimation.

## Authors’ abstract

Continuum robots are well suited for gentle manipulation because of their inherent compliance and ability to adapt to complex environments. However, their continuously deformable structure makes accurate configuration estimation challenging, particularly when external vision systems are unavailable or obstructed. In this work, we present an embedded pose sensing framework that combines inertial measurement units (IMUs) and active magnetic fields to estimate the robot…

[The full abstract on arXiv](https://arxiv.org/abs/2609.39950)

[Read the original paper](https://arxiv.org/abs/2609.39950)

## Related papers

- [A QCQP-Representable IMU Pre-Integration Factor for Certifiable State Estimation](https://robotics.world/paper/a-qcqp-representable-imu-pre-integration-factor-for-certifiable-state-2609.38048) 2026-09-29 · cs.RO · Key terms of the title in common
- [Anatomy-Aware Dexterity-Driven Design Optimization of Surgical Continuum Robots](https://robotics.world/paper/anatomy-aware-dexterity-driven-design-optimization-of-surgical-2609.30745) 2026-09-25 · cs.RO · Key terms of the title in common
- [Bayesian Continuum Robot Dynamics and State Estimation](https://robotics.world/paper/bayesian-continuum-robot-dynamics-and-state-estimation-2609.20605) 2026-09-17 · cs.RO · Key terms of the title in common
- [Underwater Visual Target Tracking with Target-Specific Depth Estimation and Adaptive Model-Fusion Predictive Control](https://robotics.world/paper/underwater-visual-target-tracking-with-target-specific-depth-estimation-2609.20731) 2026-09-17 · cs.RO · Key terms of the title in common
- [Smart Fusion for Adaptive Visual-IMU Weighting in cuVSLAM Sparse Bundle Adjustment](https://robotics.world/paper/smart-fusion-for-adaptive-visual-imu-weighting-in-cuvslam-sparse-bundle-2610.20226) 2026-10-14 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/magnetic-based-in-situ-self-3d-pose-estimation-for-a-modular-soft-2609.39950