Skip to content
Robotics.world

Research

Multi-Objective Human-in-the-Loop Bayesian Optimization of a Lower-Limb Exoskeleton

Personalizing an exoskeleton controller normally means optimizing one number, most often metabolic cost, or forcing a fixed weighting between several numbers chosen before the experiment begins.

The paper’s first page · arXiv:2609.30695
arXiv
2609.30695 · Preprint · not peer-reviewed
Published
2026-09-25
Authors
Neil Janwani, Matthew T. Lerner, Aaron J. Young, Maegan Tucker

In plain words

Personalizing an exoskeleton controller normally means optimizing one number, most often metabolic cost, or forcing a fixed weighting between several numbers chosen before the experiment begins. Neither approach captures how a specific person actually trades off competing goals like efficiency versus comfort, and that trade-off may shift with mood, environment, or fatigue.

AI summary

Overview

Research area: Human-in-the-loop optimization (HILO) for wearable assistive robotics, combining multi-objective Bayesian optimization with real human subject experiments on a lower-limb exoskeleton.

Technical level: Intermediate. Readers will benefit from familiarity with Gaussian processes, Bayesian optimization, and the concept of Pareto optimality, though the paper explains its setup from first principles.

Scope: The paper introduces MO-HILBO, a sample-efficient method for inferring a personalized set of Pareto-optimal exoskeleton controllers that trade off metabolic cost against subjective comfort, and validates it in a three-participant human study.

What This Paper Is About

Personalizing an exoskeleton controller normally means optimizing one number, most often metabolic cost, or forcing a fixed weighting between several numbers chosen before the experiment begins. Neither approach captures how a specific person actually trades off competing goals like efficiency versus comfort, and that trade-off may shift with mood, environment, or fatigue. The authors propose MO-HILBO, which instead learns an entire Pareto front of mutually non-dominated controllers from a small budget of noisy human feedback, and they test it on a lower-limb exoskeleton across two objectives: metabolic cost and ordinal comfort ratings.

Key Contributions

  1. A new protocol, MO-HILBO, presented as the first multi-objective human-in-the-loop Bayesian optimization protocol for wearable devices. It pairs an independent Gaussian process per objective (a multi-objective GP, or MO-GP) with the qLogNParEGO acquisition function from BoTorch, so that the trade-off weighting between objectives is resampled randomly each iteration rather than fixed in advance.

  2. A decoupled feedback collection scheme that allows different numbers of repeated measurements per objective per trial. This lets a fast objective (comfort, asked once per minute) be sampled repeatedly while a slow objective (metabolic cost, fit over a 3-minute trial) is being measured, reducing total experiment duration and improving surrogate quality under noise.

  3. A synthetic benchmark against the existing multi-objective HILO approach of Zhang et al., which uses NSGA-II. Across ablations on measurement noise, action dimension (n ∈ {1, 2, 3, 4}), and number of objectives (m ∈ {2, 3, 4, 5}), the underlying MOBO framework achieves lower IGD+ than NSGA-II under high noise and limited sample budgets.

  4. A validation procedure for multi-objective HILO plus a three-participant exoskeleton study optimizing 3 controller parameters over 2 objectives within a 24-query budget, and the open-source mohilo Python package for running both single-objective and multi-objective HILO on wearable devices.

Main Findings

  • MO-HILBO found genuine Pareto-optimal controllers: For every subject, the three validation controllers drawn from the inferred Pareto set empirically Pareto-dominated the three controllers drawn from the anti-Pareto set (built by negating the objectives). Reported hypervolume estimates were 4.02 versus 1.300 for MB01, 1.55 versus 0.366 for MB02, and 1.02 versus 0.128 for MB03, with the caveat that a different valid reference point was used per subject so the scales differ.

  • Pairwise ordering predictions were largely correct: MO-HILBO predicted 94% (17/18) of the pairwise orderings among Pareto-optimal validation controllers. Metabolic cost ordering was 100% (3/3) for MB01 and MB02 and 67% (2/3) for MB03; comfort ordering was 100% (3/3) for all three subjects. These were controllers not seen during training.

  • The search space collapsed from three dimensions to roughly one: MO-HILBO maps the 3-dimensional action space into an approximately 1-dimensional manifold of trade-off controllers. For MB03, the Pareto set clustered around low delay and low hip extension scale, with hip flexion scale acting as the primary decision variable governing the comfort-versus-efficiency trade-off. MB03's most comfortable gait was with the exoskeleton effectively off, while the most efficient controller had hip flexion torque scale nearly maximized.

  • Cross-subject structure was mixed: All three subjects found high delay to be neither comfortable nor efficient. MB02 and MB03 (both new to the device) found low torque most comfortable, whereas MB01 (the only experienced wearer) found high flexion and extension torque both comfortable and efficient. The authors suggest this points to non-stationary factors such as adaptation and prior exposure.

  • MOBO beat NSGA-II in the noise-limited regime: In synthetic experiments, MOBO reached a lower IGD+ score within 40 queries and converged by 100 queries, while NSGA-II convergence slowed as noise increased. MOBO with n ∈ {1, 2, 3} converged quickly; MOBO with n = 4 still outperformed NSGA-II at n = 4 but with a higher IGD+ score, indicating that higher action dimensions remain a challenge. NSGA-II began to plateau at higher IGD+ values as the number of objectives grew.

  • The learned posterior reveals what subjects disliked, not just what they liked: Because MO-HILBO learns a posterior over the entire action space rather than only the Pareto set, it can report regions a subject rejected. For MB03, high torque combined with high delay was uncomfortable, and high delay combined with high flexion torque was inefficient.

Methodology in Plain English

The problem is framed as finding a set of controller settings where no single setting can be improved on one objective without getting worse on another. Evaluating each candidate setting requires a human to walk on a treadmill and give feedback, which is expensive, so the method builds a statistical model — one Gaussian process per objective — that predicts both the expected value and the uncertainty of each objective anywhere in the parameter space. Each Gaussian process uses an automatic relevance determination squared-exponential kernel, with a minimum lengthscale of 0.1 to prevent overfitting, and hyperparameters are fit by maximizing a posterior that includes a practitioner-specified prior on measurement noise rather than the log marginal likelihood alone.

The loop proceeds as follows: for the first 3 queries (T₀ = 3), controller parameters are sampled uniformly at random because no posterior exists yet. After that, an acquisition function picks the next controller. That function is qLogNParEGO: it draws a random weight vector from the simplex, collapses the multi-objective problem into a single scalar value using an augmented Chebyshev scalarization with α_aug = 0.05, and then scores candidates by expected improvement over the best scalarized observed value. Because the weights are redrawn each call, the algorithm naturally sweeps across different prioritizations instead of committing to one. BoTorch handles the maximization.

Before fitting, all parameters are normalized to a unit hypercube and all objectives are standardized and sign-flipped so the code can always maximize. Feedback is collected in a decoupled way: each objective j can have c_j repeated measurements per trial, so comfort can be queried multiple times during a single 3-minute metabolic measurement window. Refitting happens after every iteration, and after 24 queries the surrogate mean is evaluated on a dense sample of the action space to extract the estimated Pareto set.

For the human study, the exoskeleton controller has three parameters: a temporal delay δ ∈ [0, 0.375] seconds applied to the estimated biological joint moment from a temporal convolutional neural network, and two scaling coefficients β₁, β₂ ∈ [0, 0.3] applied during positive and negative moment phases respectively. Only the hip was actuated; knee actuators commanded zero torque. Three participants walked at 1.2 m/s while metabolic cost was estimated via indirect calorimetry using a first-order dynamical model fit to breath-by-breath data and comfort was rated on a 1–5 scale on a tablet once per minute.

Validation used six controllers evaluated for 5 minutes each in randomized order: three sampled from the inferred Pareto set (two endpoints, one interior) and three from the anti-Pareto set. Two tests were applied — a 3-point hypervolume estimate to confirm dominance, and a comparison of predicted versus measured pairwise rankings across the three pairwise combinations per objective.

Why This Matters

Impact on research. Prior multi-objective HILO work required either a fixed scalarization weight known before the experiment or an evolutionary search that rolls out whole generations and produces sparse front approximations. MO-HILBO removes the need to pre-specify preferences and produces a dense, continuous approximation of the front from a small noisy budget, which the synthetic ablations show is the regime where evolutionary methods degrade. The validation protocol is also a contribution in its own right, since multi-objective HILO previously lacked a standard way to check that an inferred front is actually correct.

Real-world applications:

  • Rehabilitation and assistive gait training, where a clinician needs to see the menu of viable efficiency-versus-comfort trade-offs rather than a single tuned setting, and where a patient's priorities may change as they recover.
  • Wearable robots for occupational and industrial use, where a worker might favor efficiency on a long shift but favor comfort or speed in other contexts.
  • Prosthetics and powered orthoses, where the same personalization problem applies and where subjective fit is as important as metabolic outcome.
  • Consumer exoskeletons and exosuits, where an out-of-the-box controller must be adapted to a very wide range of body types and gait styles without lengthy expert-supervised tuning sessions.

Industry relevance. The 24-query, 3–4 hour single-session protocol is short enough to be practical outside a lab, and the released mohilo package lowers the barrier for companies to deploy sample-efficient personalization on commercial hardware. The finding that the 3-parameter search collapses to roughly a 1-dimensional manifold is also commercially relevant, since it suggests real-time or near-real-time in-field tuning may be feasible.

Future Directions

  • Modeling non-stationarity. Standard Bayesian optimization assumes a stationary objective. The authors note that human adaptation, fatigue, and shifting preferences violate this, and propose modeling these dynamics as distinct regions of the Pareto set. The observed difference between the experienced participant (MB01) and the two first-time wearers (MB02, MB03) motivates studying how fronts evolve over extended device exposure.

  • Interactive search for many objectives. As the number of objectives grows, Pareto sets become large and hard for a human to navigate. The authors suggest interactive search algorithms to help users explore high-dimensional fronts in a tractable, user-centered way.

  • Extending beyond two objectives and three parameters. The synthetic study covered up to m = 5 objectives and n = 4 action dimensions, and found n = 4 to be a challenge for the surrogate. Real device studies at those scales remain untested.

  • Closing the loop in real time. The reduced 1-dimensional representation is described as offering a simplified search space for real-time human-in-the-loop tuning, which the authors flag as an exciting future research direction rather than something demonstrated here.

Target Audience

This paper is most useful to researchers and engineers working on personalization of wearable robots — exoskeletons, prostheses, and exosuits — who already use or are considering human-in-the-loop optimization and want to move beyond single-objective or fixed-weight formulations. It is also relevant to Bayesian optimization practitioners looking for a demanding real-world application with ordinal and costly-to-measure objectives, and to clinical or industrial teams who need a concrete, short-budget protocol for tuning a device to an individual. Readers seeking closed-form theory or large-cohort statistical evidence should note that the human study involves three participants and reports per-subject validation results rather than population-level statistics, and the authors do not report significance testing.

Authors’ abstract

Human-in-the-loop optimization (HILO) is a common approach for optimizing the control of assistive devices to account for the wearer's unique biomechanics and subjective preferences. However, despite research suggesting that a person may have a different prioritization of objectives depending on time-varying factors such as the environment, their mood, or energy levels, existing HILO approaches only consider a single objective or enforce a fixed weighting on a set of…

The full abstract on arXiv
Read the original paper

Related papers