> Total-body photography (TBP) systems image the whole skin surface quickly but do not reach dermatoscopic resolution, so any suspicious lesion still has to be re-examined by hand with a handheld…

**arXiv**: 2609.10169 · Preprint · not peer-reviewed

**Published**: 2026-09-09 · revised · 2026-09-10

**Authors**: Valerio Franchi, Rafael Garcia, Nuno Gracias, Ricard Campos, Josep Quintana, Sandra González-Villà, Mark Ventura, Nuria Ferrera, Clément Lenoir, Josep Malvehy

## In plain words

Total-body photography (TBP) systems image the whole skin surface quickly but do not reach dermatoscopic resolution, so any suspicious lesion still has to be re-examined by hand with a handheld dermatoscope — a slow, operator-dependent step.

## AI summary

## Overview

**Research area:** Medical robotics / multi-robot systems, computer vision, and dermatological imaging (full-body skin screening).

**Technical level:** Intermediate to Advanced. The paper assumes familiarity with robot calibration (eye-in-hand, stereo), view planning, focus stacking, super-resolution networks, and 3D deformable human body models.

**Scope (one sentence):** The paper describes the mechanical, optical, vision, and control design of a four-cobot full-body scanner that automatically captures non-contact dermatoscopic-quality images of skin lesions, and evaluates it against contact dermoscopy and the Vectra WB360 total-body photography system on 156 lesions from real patients.

## What This Paper Is About

Total-body photography (TBP) systems image the whole skin surface quickly but do not reach dermatoscopic resolution, so any suspicious lesion still has to be re-examined by hand with a handheld dermatoscope — a slow, operator-dependent step. The authors build a scanner in which four collaborative robot arms carry camera heads to automatically locate moles, move into position, and capture focused, dermatoscopic-level images without touching the patient. The goal is to close the gap between whole-body mapping and handheld dermoscopy by automating the close-up acquisition step.

## Key Contributions

1. **A four-cobot full-body imaging platform.** Four UR10e CSI collaborative robots (12.5 kg payload, 130 cm reach) each cover one quadrant of the patient lying on a medical bed, with a custom 3D-printed (Pa11 glass-filled) end-effector holding the cameras, surrounded by a sphere-shaped protective housing.
2. **A view-planning and control stack for autonomous lesion imaging.** A planner uses the patient's 3D reconstruction to run a full-body exploration pass at 40 cm, then computes optimal per-lesion camera poses at 30 cm, while a high-level controller lets the robots work simultaneously and a collision detector halts them on contact with an object or a person.
3. **A gravity-compensated liquid-lens optical design enabling non-contact dermoscopy.** A second liquid reservoir and membrane passively cancel the gravity-induced coma that appears when a tunable liquid lens is used with a horizontal optical axis, allowing rapid through-focus image stacks, focus stacking, sub-pixel registration, and super-resolution.
4. **A quantitative clinical evaluation.** Real-patient scans compared against contact dermoscopy (Canfield D200EVO) and Vectra WB360 across clinically relevant lesion features on 156 lesions, plus an objective USAF 1951 resolution measurement: 22.1 µm smallest resolvable feature for the scanner versus 8.8 µm for contact dermoscopy.

## Main Findings

- **Optical resolution:** On a USAF 1951 target, the contact dermatoscope resolved Group 5, Element 6 (8.8 µm feature size) while the scanner resolved Group 4, Element 4 (22.1 µm), both measured at their respective working distances (contact for the dermatoscope, 26 cm for the scanner).
- **Super-resolution does not improve true optics:** Pixel sampling density rises from about 68 px/mm (Native, GPEN pipeline, about 15 µm/px) to about 137 px/mm (SR, Real-ESRGAN with SRVGGNetCompact, about 7 µm/px), but measured true optical resolution stays at 22.1 µm for both pipelines — the paper notes this distinction between pixel resolution and optical resolving power.
- **Comparison with Vectra:** The scanner consistently outperforms the Vectra WB360 across most clinically relevant lesion features.
- **Comparison with contact dermoscopy:** The scanner achieves performance comparable to contact dermoscopy for the majority of features assessed, while remaining slightly below it in true resolving power.
- **Dataset:** 156 lesions, each imaged with four modalities (Vectra, dermoscopy, Native, SR); lesion diameters range from 0.7 mm to 16 mm, mean 3.2 (1.9) mm, with most falling in the 2.2 mm to 3.7 mm range.
- **Resolution of the comparators:** Dermoscopy about 187 px/mm (about 5 µm/px); Vectra about 10 px/mm (about 105 µm/px), a value the authors state is derived from sensor specifications and not independently validated by them; Vectra's true optical resolution is listed as N/A.
- **Adaptive positioning:** The system accommodates diverse body shapes by design, with patient specifications of 140–190 cm total height, 20–45 cm thorax height (lying face up), and 40–50 cm elbow-to-elbow.

## Methodology in Plain English

The patient lies on a bed inside a frame of four robot arms. Each arm's hand carries a cluster of cameras: a wide-angle 2D camera, a 3D time-of-flight camera, and a high-resolution dermoscopic camera built around a 75 mm lens with a tunable liquid lens.

The process runs in stages. First, all four arms move to preset poses and build a rough textured 3D model of the patient from the 2D and 3D cameras, with cross-polarized lighting to kill skin glare. The planner then computes a denser set of views at 40 cm and the wide-angle images are fed to a YOLOv8 detector that finds pigmented lesions larger than 3 mm in diameter. Each detection is lifted into 3D using the depth camera, giving a position and a surface normal.

For each lesion the planner computes a camera pose at 30 cm with a safety margin, and the arms are dispatched in parallel. Because skin topography can exceed a single depth of field, the liquid lens sweeps through several dioptre settings — the dioptre-to-distance mapping having been calibrated beforehand with a polynomial fit using a sharpness metric (Normalised Gray Level Variance) — and the resulting stack is aligned by sub-pixel registration and merged by focus stacking into one fully sharp image. Two post-processing pipelines were compared: one using a pretrained GPEN super-resolution model (Native) and one using a self-trained Real-ESRGAN/SRVGGNetCompact model (SR).

Everything depends on careful calibration. A ChAruco pattern hidden under the mattress, with 1 cm squares for the wide-angle camera, 3 cm squares for the 3D camera, and 0.5 cm squares for the dermoscopic cameras, supports a six-step procedure: intrinsics for the wide-angle camera, eye-in-hand calibration, stereo calibration between wide-angle and 3D cameras, intrinsics for the dermoscopic camera, stereo calibration between dermoscopic and wide-angle cameras, and liquid-lens dioptre calibration.

Finally, the raw 3D mesh is fitted with an SMPL deformable human model — 300 shape parameters (the first 10 capture most body variation) and a 24×3 pose vector — by estimating joint locations from OpenPose on several rendered views, then optimizing against joint discrepancies and the Hausdorff distance to the patient mesh, with a pose prior to forbid anatomically impossible poses. This yields a semantic, anonymized avatar for querying ("all moles on the left arm") and for comparing scans over time. The operator runs the scan from a 24-inch touchscreen HMI plus a Bosch Easy Panel with dedicated stop, pause, homing, and error-acknowledge buttons, backed by emergency stops around the machine.

## Why This Matters

**Research impact:** The work shows that a multi-arm robotic system can deliver non-contact images close to handheld dermoscopy quality across the whole body in one automated session, and it introduces a practical fix (passive dual-membrane gravity compensation) for a known limitation of liquid lenses used horizontally — a configuration most robotic vision systems need.

**Real-world applications:**

- High-throughput skin cancer screening for patients with atypical mole syndrome or very large numbers of naevi, where manual lesion-by-lesion dermoscopy is slow.
- Longitudinal lesion tracking, using the SMPL avatar as a common frame to compare the same lesion across visits and flag new or changing lesions.
- Tele-dermatology and remote review, since scans are anonymized 3D avatars plus stored lesion images rather than live patient contact.
- Standardized, operator-independent image capture for clinical trials and archives, reducing variability between examiners.

**Industry relevance:** The system is built entirely from commercial parts (Universal Robots UR10e CSI, Lucid Triton and Helios2+, Oryx 10GigE, Optotune EL-16-40-GTC, Evetar optics) and is benchmarked against an established clinical product (Vectra WB360), which makes the design directly relevant to makers of total-body photography hardware and to clinical imaging integrators.

## Future Directions

- **Closing the resolution gap:** True optical resolution is 22.1 µm versus 8.8 µm for contact dermoscopy, and super-resolution did not change the measured optical limit, so improved optics or a different illumination/objective design would be needed to match contact dermoscopy.
- **Clinical validation at scale:** The evaluation covers 156 lesions; larger studies with diagnostic endpoints and multiple clinical sites would be needed to establish screening utility.
- **Workflow integration:** The authors position the scanner as a potential component of screening workflows, which raises open questions about scan time, throughput, and how the automated images would be read and acted on by dermatologists.
- **Robustness outside the lab:** Liquid lens performance depends on matched liquids and membrane stiffness under conditions such as 20 °C ± 5 °C in hospital environments and uncontrolled transport or storage, so long-term reliability and calibration drift are natural next questions.

## Target Audience

Robotics researchers working on multi-arm coordination, view planning, and robot-mounted optical systems; medical-imaging and computer-vision engineers interested in focus stacking, super-resolution, and 3D body modeling; and dermatologists, clinical imaging specialists, and device developers evaluating automation of total-body photography and dermoscopy.

## Authors’ abstract

This paper outlines the specifications and design approach used to construct a full body imaging scanner capable of capturing skin lesions at a dermatoscopic level using cameras mounted on the end-effectors of four UR10 manipulators. The system possesses a view-planning algorithm capable of appropriately selecting the best camera position to acquire images of moles, a high-level controller to allow the manipulators to work simultaneously and a collision-detector that halts…

[The full abstract on arXiv](https://arxiv.org/abs/2609.10169)

[Read the original paper](https://arxiv.org/abs/2609.10169)

## Related papers

- [Advancing Accessible Underwater Robotics: The Mini-Girona I-AUV at RAMI 2025](https://robotics.world/paper/advancing-accessible-underwater-robotics-the-mini-girona-i-auv-at-rami-2609.02605) 2026-09-02 · cs.RO · Also by Nuno Gracias
- [MSK-Bench: Benchmarking Full-Body Musculoskeletal Motor Control Across Tasks, Control Paradigms, and Physiological Metrics](https://robotics.world/paper/msk-bench-benchmarking-full-body-musculoskeletal-motor-control-across-2609.26872) 2026-09-22 · cs.RO · Key terms of the title in common
- [SwingBot: Learning Whole-Body Brachiation for Humanoid Robots](https://robotics.world/paper/swingbot-learning-whole-body-brachiation-for-humanoid-robots-2609.10283) 2026-09-09 · cs.RO · Key terms of the title in common
- [Bridging Language and Physics: Automated Design of Continuum Robots with Large Language Models](https://robotics.world/paper/bridging-language-and-physics-automated-design-of-continuum-robots-with-2609.08220) 2026-09-08 · cs.RO · Key terms of the title in common
- [An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework](https://robotics.world/paper/an-automated-thickness-evaluation-procedure-using-an-integrated-2609.12206) 2026-09-10 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/multi-robot-scanner-for-automated-full-body-dermoscopic-imaging-2609.10169