OCTN: Neural OCT Representations for Robot-Guided Precision Intervention

OCT gives micron-scale, contactless, near-real-time tissue imaging in a compact form factor, which makes it attractive for surgical guidance. But native OCT volumes are stored as discrete voxel grids…

The paper’s first page · arXiv:2609.06810
arXiv
2609.06810 · Preprint · not peer-reviewed
Published
2026-09-06
Authors
Ravi Prakash, Ryan P. McNabb, Patrick J. Codd, Shan Lin

In plain words

OCT gives micron-scale, contactless, near-real-time tissue imaging in a compact form factor, which makes it attractive for surgical guidance. But native OCT volumes are stored as discrete voxel grids with anisotropic spacing, and reasoning over tens of millions of voxels is slow and awkward for downstream geometry and robot planning.

AI summary

Overview

Research area: Medical robotics and intraoperative imaging — specifically, implicit neural representations (INRs) of optical coherence tomography (OCT) volumes for robot-guided intervention.

Technical level: Intermediate. Readers should be comfortable with deep learning basics (MLPs, coordinate-based representations, loss functions) and with standard 3D image metrics (PSNR, SSIM, Chamfer distance). No prior OCT optics background is assumed, but the paper moves quickly through acquisition terminology (A-scans, B-scans, C-scans).

Scope in one sentence: The paper introduces OCTN, a GPU-native neural field that turns discrete, anisotropic OCT volumes into a continuous, differentiable intensity field, and demonstrates three uses — fast volumetric queries, surface-constrained laser path planning, and dense reconstruction from sparsely acquired B-scans.

What This Paper Is About

OCT gives micron-scale, contactless, near-real-time tissue imaging in a compact form factor, which makes it attractive for surgical guidance. But native OCT volumes are stored as discrete voxel grids with anisotropic spacing, and reasoning over tens of millions of voxels is slow and awkward for downstream geometry and robot planning. The authors' goal is to replace that grid with a continuous neural function mapping 3D coordinates to tissue intensity, so that the same learned field can be queried quickly, differentiated for surface discovery, and sampled between acquired slices to cut acquisition time.

Key Contributions

  1. A hybrid two-stage training framework for continuous OCT representation. Stage I mixes acquired discrete voxels with trilinearly interpolated inter-slice samples in a ratio set by α, encouraging off-grid continuity; Stage II refines on native voxels only to restore B-scan fidelity. Coordinates are normalized to a canonical [−1, 1]³ frame so the representation is resolution-agnostic.

  2. GPU-native querying and OCT-guided robot path planning. The learned field is stored on the GPU, giving 19× to 43× faster intensity-based volumetric queries than CPU processing (2× over GPU and 3× overall for the full pipeline). The same field supports implicit surface discovery and surface-constrained raster path planning using either Newton-based root-finding or SGD-based optimization on an OCT-guided robotic laser platform.

  3. Sparse-volume reconstruction. OCTN reconstructs dense volumetric structure from subsampled B-scan stacks, supporting up to a 4× reduction in B-scan density — for a critically sampled volume, acquisition time drops from 24 s to 6 s.

  4. The Duke TissueOCT dataset and benchmarking suite. An open-source set of 46 critically sampled ex vivo OCT volumes (porcine muscle at high and low SNR, porcine muscle with dye artifacts, chicken breast, bovine tissue) with calibration parameters, plus global and local metrics for B-scan fidelity, sparse-to-dense reconstruction, query speed, and surface-aware path planning.

Main Findings

  • Fast volumetric queries. For a native 256 × 512 × 512 volume (67,108,864 voxels), OCTN infers roughly 67M points in 0.158 s, with an additional 0.0243 s to build the uniform grid and convert from canonical to physical coordinates. The full process is 2× faster than a GPU baseline and 3× faster than CPU; query-only timing is about 19×, 40×, and 43× faster than CPU across the three intensity bands. The gap widens as the number of queried points grows, because conventional GPU search utilization rises with point count while OCTN's inference batch utilization stays constant.

  • Query accuracy stays sub-clinical. Chamfer distance between OCTN and ground-truth point clouds was 0.0423 mm, 0.0264 mm, and 0.0158 mm for the [0.2, 0.4), [0.4, 0.6), and [0.6, 1.0] intensity bands, all below 42 μm and well inside the stated < 0.5 mm clinical error threshold. Hausdorff distance fell from 1.572 mm to 1.451 mm to 0.963 mm as the point sets became sparser.

  • Newton path planning is much faster than kNN. On a 3 mm × 3 mm raster over porcine tissue, the Newton method found the surface 10× faster than the kNN baseline and placed 32.8% of points on the surface, versus 12.5% for the baseline.

  • SGD path planning trades hit rate for smoothness. The SGD formulation, which jointly minimizes an iso-surface loss and a second-order smoothness term, produced the smoothest trajectory — a 56.9% reduction in depth smoothness energy over baseline — at 15.6% of points on the surface and requiring roughly 5× lower computational speed.

  • Sparse reconstruction degrades predictably. OCTN matched or exceeded trilinear interpolation on held-out B-scans across subsampling factors SF ∈ {2, 4, 8, 16, 32}. Blurring of fine features appears at SF = 8× (224 μm inter-slice distance, 32 of 256 B-scans retained) and becomes substantial at SF = 32× (896 μm spacing, 8 of 256 B-scans). Neither method recovers high-frequency structure that was never acquired.

  • Cross-dataset reconstruction quality. Global PSNR/SSIM was 44.64 dB / 0.996 on Srinivasan, 45.05 dB / 0.995 on Harvard, 49.00 dB / 0.997 on Noor Eye, and 35.61 dB / 0.833 on TissueOCT. Local region-of-interest analysis on the high-speckle TissueOCT data shows PSNR and SSIM gains for regions R1 and R2 but degradation at the air–tissue boundary (R3, −6.21 dB). Gaussian- and Median-smoothed TissueOCT variants show higher global metrics but degraded local performance, which the authors attribute to speckle smoothing inflating the global score. EPI is approximately 1 across datasets, indicating edge structure is preserved relative to ground truth.

  • Training is fast. Acceptable PSNR (30 dB) is reached in less than 10 s on average, and reconstruction quality tends to improve as the total number of voxels in a dataset decreases. All reported metrics were collected on a single NVIDIA 4080 Super; the method was also tested on NVIDIA 3070 Ti and 5090 GPUs.

  • Coarse initialization is necessary. Depth values initialized in air have near-zero intensity gradients and fail to migrate to the tissue boundary, so a warm-up axial search over N_warmup candidate depths precedes any gradient-based refinement. Newton updates are additionally safeguarded by skipping small gradients, clamping steps, and restricting refinement to a neighborhood around the coarse estimate.

Methodology in Plain English

The team treats a tissue scan the way a graphics researcher treats a 3D scene: instead of storing a giant stack of voxels, they train a small neural network that answers the question "what is the tissue brightness at this exact point in space?" Coordinates are first rescaled into a cube from −1 to 1, and a multiresolution hash encoder (24 levels, 2 features per level, hash table of size 2²⁰, base resolution 16) projects each coordinate into a high-dimensional feature vector so fine tissue texture is not smoothed away. A fully fused MLP with three hidden layers of 128 neurons and ReLU activations then regresses a single intensity value.

Training happens in two phases. Early on, each batch deliberately mixes real sampled voxels with made-up in-between samples produced by trilinear interpolation — the fraction of the latter is α (set to 0.20 in the reconstruction experiments). This stops the network from only being accurate exactly where data exists. Later, training switches to real voxels only, sharpening fidelity on the native grid. Loss is mean squared error, optimized with ADAM.

The engineering choices matter as much as the math. The whole volume lives on the GPU, samples are drawn on the fly with CUDA-accelerated interpolation and tensor indexing, and Tiny-CUDA-NN fuses operations into single kernels. This avoids the data-loader and memory-bandwidth bottlenecks that make comparable INR methods slow.

For evaluation, three protocols are used. Intermediate slices are rendered at 0.25-slice intervals between anchor B-scans near the volume center and compared against trilinear proxies. Sparse reconstruction subsamples B-scans by a factor SF, trains only on the retained slices, then queries the frozen model at the held-out slice locations and compares against real measurements. For robot planning, the tissue surface is defined as an intensity level set at threshold τ (the median intensity of a surface extracted by axial gradient), raster depth values are coarsely initialized by picking the depth of maximum axial gradient, and then refined either by Newton root-finding on f_θ − τ or by SGD on a combined surface-plus-smoothness loss where a binary mask prevents smoothing across raster turns.

Why This Matters

Impact on research. The paper reframes OCT volumes as queryable functions rather than arrays, which changes the interface between imaging hardware and robotic software. It also contributes a benchmark with deliberately varied noise, tissue type, and optical contrast — the authors argue INRs are prone to overfitting easy structures, so a homogeneous dataset would give misleading results. Reporting both global and local metrics exposes a failure mode (smoothed volumes scoring well globally while degrading at tissue boundaries) that global-only reporting would hide.

Real-world applications:

  • Laser microsurgery and tumor ablation, where a fixed focal offset from a moving tissue surface must be maintained while keeping robot motion smooth.
  • Neurosurgical and head-and-neck procedures where OCT has been explored and intraoperative ultrasound's roughly 0.5 mm resolution is a limiting factor.
  • Ophthalmology, where OCT is already established clinically and the public datasets used (Srinivasan, Harvard GDP, Noor Eye) come from this domain.
  • Faster scanning protocols in any OCT-guided workflow, since reconstructing from 4× fewer B-scans cuts a 24 s acquisition to 6 s.

Industry relevance. Training in under 10 s and inference on consumer GPUs (3070 Ti, 4080 Super, 5090) lowers the barrier to embedding this in surgical systems, simulation, and robot control loops. The authors have filed a provisional patent (U.S. 64/045,412) and released the dataset and code, which positions this as infrastructure for OCT-guided robotics rather than a single-task model.

Future Directions

  • Closing the smoothing gap at tissue boundaries. The R3 degradation on high-speckle TissueOCT (−6.21 dB PSNR) marks the air–tissue interface as the hardest region; better handling of surface-adjacent speckle is a clear next target.
  • Improving the smoothness-versus-coverage trade-off in planning. Newton reaches 32.8% surface points while SGD reaches 15.6% but is far smoother. Finding a formulation that achieves both, or learning λ rather than tuning it, is an open design question.
  • Pushing beyond 4× subsampling. Performance collapses between SF = 8× and SF = 32×; learned priors or physics-informed A-scan models — which the paper cites as an alternative route — could extend the usable range.
  • Validation beyond ex vivo tissue. The dataset is ex vivo animal tissue, and the planning experiments are on porcine samples. In vivo validation and clinical accuracy studies are the necessary next step before deployment claims can be made.

Target Audience

Robotics and medical-imaging researchers working on intraoperative sensing, image-guided intervention, and neural field representations; OCT system developers interested in reducing acquisition burden; and surgical-robotics engineers who need fast, differentiable geometric reasoning over imaging data. It is also a useful case study for graduate students learning how implicit neural representations transfer from computer vision to a modality with strong physical idiosyncrasies (speckle, anisotropy, limited field of view).

Note: the supplied text truncates mid-sentence in Section III-D ("highlight improv"), so the final portions of the results and any stated limitations or future work in the original manuscript are not available here and are not reported above.

Authors’ abstract

Optical coherence tomography (OCT) offers compact, contactless, micron-scale imaging suitable for intraoperative guidance, but native OCT volumes are discretely sampled, anisotropic, and currently inefficient for downstream geometric reasoning and robot integration. We present OCTN (pronounced "octane"), an implicit neural representation framework that converts volumetric OCT scans into a continuous, differentiable, and spatially faithful tissue-intensity field. OCTN uses a…