# Proprioceptive Finger Force Estimation for Reliable Box Manipulation

Robotics.world

> A robot picking up a box must squeeze hard enough not to drop it, but not so hard that it crushes the box or its contents. Boxes that look identical can differ in mass and stiffness, so a fixed…

**arXiv**: 2610.38351 · Preprint · not peer-reviewed

**Published**: 2026-10-28

**Authors**: Junha Cha, Chanwoo Kim, Kisang Park, Yeoncheol Jang, Doyoung Kim, Seungmin Kim, Kyungjae Lee, Sungjoon Choi

## In plain words

A robot picking up a box must squeeze hard enough not to drop it, but not so hard that it crushes the box or its contents. Boxes that look identical can differ in mass and stiffness, so a fixed finger motion can succeed on one box and damage the next.

## AI summary

## Overview

**Research area:** Robotic manipulation — proprioceptive (sensor-free) force estimation and force-based grasping control.

**Technical level:** Intermediate to Advanced. The paper assumes familiarity with virtual-spring contact models, Mixture Density Networks, and position-controlled tendon-driven hands, but the core idea (learn the error of a simple physical model) is easy to grasp.

**Scope:** The paper proposes FEEL, a method that estimates per-finger external force magnitude from joint encoders alone by correcting a calibrated virtual-spring estimate with a learned residual distribution, and shows that using these estimates to regulate individual fingers during box pick-and-place removes box damage without losing task success.

## What This Paper Is About

A robot picking up a box must squeeze hard enough not to drop it, but not so hard that it crushes the box or its contents. Boxes that look identical can differ in mass and stiffness, so a fixed finger motion can succeed on one box and damage the next. The authors ask whether a robot can get per-finger force feedback using only the joint position sensors it already has — no fingertip force/tactile sensors — and whether that feedback makes box handling more reliable.

## Key Contributions

1. **An uncertainty-aware residual force estimator (FEEL).** Each finger's force magnitude is estimated as a calibrated virtual-spring term plus a residual predicted by a Mixture Density Network (MDN) from a 0.1-s history of measured joint positions and joint tracking errors. No dedicated contact sensor is used at deployment.
2. **A closed-form predictive uncertainty signal.** Because the residual is modeled as a Gaussian mixture, its predictive variance splits into within-component (aleatoric) and between-component (epistemic) terms from a single forward pass. The authors analyze this as an empirical indicator of ambiguity rather than a calibrated uncertainty measure.
3. **A real-robot benchmark against two baselines.** Per-finger stiffness is identified by least-squares fitting on a separate calibration set, and the residual MDN is compared against the virtual spring alone and an end-to-end MDN that predicts force directly, on identical five-fold cross-validation splits over ten fingers.
4. **A real-robot manipulation study.** Continuous per-finger force adaptation is evaluated in a box pick-and-place task with separate success, damage-free, and combined "reliability" outcomes, plus a controller-gain sensitivity study showing that the most accurate estimator does not give the most reliable manipulation.

## Main Findings

- **Force estimation accuracy:** Across ten fingers and contact forces spanning 0–20 N, the residual MDN achieves a mean RMSE of **0.251 N**, versus **3.493 N** for the virtual spring and **0.277 N** for the end-to-end MDN. This is a **92.8%** error reduction relative to the virtual spring and **9.4%** relative to the end-to-end MDN.
- **Per-finger variation:** Thumbs are the hardest fingers (left thumb: 5.327 N virtual spring, 0.790 N end-to-end MDN, 0.723 N residual MDN; right thumb: 5.361 N, 0.718 N, 0.669 N). The residual MDN has the lowest mean RMSE for both hands (0.245 N left, 0.257 N right), but the end-to-end MDN is slightly better on three individual fingers (left middle 0.093 vs 0.096 N, left little 0.103 vs 0.106 N, right middle 0.132 vs 0.147 N).
- **Distribution beats point prediction:** Replacing the MDN head with a scalar residual MLP raises overall RMSE from 0.251 N to **0.270 N**, suggesting multiple residual modes occur for similar proprioceptive histories.
- **Simulation does not transfer:** Under matched commands (left index finger, three-tap sequence in MuJoCo versus the real robot), simulated and measured force traces differ with an RMSE of **5.287 N**, which is why training uses real force/torque measurements.
- **Box manipulation:** With fixed finger commands, 10/10 trials completed but only 7/10 were damage-free, giving 7/10 reliability. With force adaptation, task success stayed at **10/10** and damage-free outcomes rose to **10/10**, so reliability improved from 7/10 to 10/10. The gain comes from avoiding damage, not from completing more trials.
- **Accuracy and reliability can trade off:** At (K_p, K_d) = (100, 200) the estimator is most accurate (**0.233 N** RMSE) but task success collapses to 4/10 (damage-free 10/10, reliability 4/10). At (300, 600) the result is 0.255 N, 9/10 success, 8/10 damage-free, 7/10 reliability — the authors note the high-gain fingers were too stiff to form a stable grasp. The (200, 400) setting balances both, with 0.251 N and 10/10 reliability.
- **Uncertainty flags ambiguous loading:** Comparing "force through joints" (held-out test samples from the same motion protocol) against "force through structure" (3,000 separately collected samples per finger, vertical load at the distal end with the commanded configuration held fixed, mean reference force 10.909 ± 6.030 N), mean aleatoric uncertainty stays similar while mean epistemic (between-component) uncertainty is higher for the structure condition. Mixture disagreement therefore signals unresolved ambiguity but cannot recover the missing force information.

## Methodology in Plain English

The starting point is a simple physical intuition: if a position-controlled finger is told to move but a box is in the way, the finger lags behind its command. The gap between commanded and measured joint positions is a proxy for how hard the finger is pressing. Treating the finger as a spring, force equals a stiffness constant times that displacement — this is the "virtual spring," and its stiffness is fitted per finger by least squares on a separate 5,000-sample-per-finger calibration set.

The problem is that a single stiffness and a single assumed contact point at the fingertip center cannot capture where the box actually touches the finger or how the finger's structure deforms. So instead of replacing the spring with a black box, the authors keep the spring estimate and train a network to predict only its error. The network sees the last ten frames (0.1 s) of four measured joint positions and four tracking errors — 80 numbers — and outputs a mixture of ten Gaussians over the residual. At inference, the mean of the highest-weight component is added to the spring estimate, and the result is clipped at zero. Two 64-unit tanh layers, 11,294 parameters, trained with AdamW for 1,000 epochs at batch size 512.

Training data comes from a wearable rig: an AFT20-D15 force/torque sensor (AIDIN Robotics) on a custom fingertip mount, read by an ESP32 with an SN65HVD230 CAN transceiver, streamed at 90 Hz while the robot replays a predefined finger motion at 100 Hz and a human presses the instrumented surface at various locations with varying force. The two clocks are synchronized and the streams aligned by timestamp, yielding 25,000 samples per finger spanning 0–20 N, including free-motion samples with no contact. Evaluation is row-level five-fold cross-validation stratified by force bins (20,000 train / 5,000 test per finger).

For manipulation, each finger's command is nudged independently each step: close if the estimated force is below a threshold, hold within a ±1-N deadband around 6 N, open above it. The task is lifting a 395 × 275 × 240 mm, 2.0 kg cardboard box and placing it on a shelf; damage is measured by tape separating from a seam prepared with 4.5 cm of low-adhesion packaging tape, with a fresh box per trial. About 120 boxes were used across the manipulation experiments.

## Why This Matters

Force feedback is the difference between a robot that grips and a robot that crushes. This paper shows that useful per-finger force feedback can be recovered from hardware most robot hands already have, and that the closed-loop benefit — eliminating damage at no cost in task success — is measurable on real boxes rather than only in simulation.

**Real-world applications:**

- **Warehouse and e-commerce logistics:** parcel picking where box contents and stiffness are unknown before the grasp.
- **Manufacturing and assembly:** handling of parts or packaging where deformation or surface damage means scrap.
- **Food and agricultural handling:** produce and packaged goods where excessive contact force causes bruising or crushing.
- **Retrofitting existing robot fleets:** adding force-aware grasping through software on hands that lack fingertip force/tactile sensors, avoiding per-finger sensor hardware and calibration.

**Industry relevance:** The appeal is cost and integration. Dedicated multi-finger force/tactile sensing adds hardware and per-location calibration; a proprioception-only estimator is a software change on an already-instrumented hand. The controller-gain study is also practically useful, because it shows that tuning gains purely to minimize estimation error is the wrong objective — the gain must be selected jointly for estimation and grasp execution.

## Future Directions

- **Resolving what proprioception cannot see:** The authors' own suggestion is to combine proprioception with complementary contact-sensitive measurements to capture force variations weakly reflected in joint responses. The "force through structure" experiment shows this is a real blind spot, not a modeling nuisance.
- **Richer contact representation:** The current formulation assumes one nominal fingertip contact point and outputs one force magnitude per finger, so it cannot localize contact, recover force direction, or handle simultaneous contacts. Extending to multi-contact or directional estimates is an open problem.
- **Calibrated rather than merely empirical uncertainty:** Predictive uncertainty is evaluated only as an empirical signal, not a calibrated measure. Turning it into something a controller can act on — for example, triggering a slower or more conservative grasp — is unaddressed.
- **Broader evaluation:** Manipulation is tested on one predefined pick-and-place motion, one box specification, and 10 trials per condition; the virtual-spring calibration is per finger and per PD gain. Testing across box masses, geometries, motions, and hands would clarify how far the result generalizes.

## Target Audience

Robotics researchers and graduate students working on manipulation, force estimation, and sensorimotor learning; engineers integrating dexterous or multi-fingered hands into logistics and manufacturing automation; and practitioners interested in residual or hybrid modeling — keeping a physical model and learning its error with a distribution rather than replacing it with an end-to-end regressor. Readers focused on tactile sensing hardware or on contact-rich manipulation with vision will find less direct relevance, since the paper deliberately excludes dedicated contact sensors at deployment.

## Authors’ abstract

Reliable box manipulation requires successful placement without damage, which depends on maintaining sufficient contact force without excessive loading. We hypothesize that per-finger force feedback improves manipulation reliability relative to open-loop finger commands. To this end, we present Finger External-Force Estimation from Proprioceptive SignaLs (FEEL), an uncertainty-aware residual method that estimates per-finger external force magnitude from proprioceptive…

[The full abstract on arXiv](https://arxiv.org/abs/2610.38351)

[Read the original paper](https://arxiv.org/abs/2610.38351)

## Related papers

- [SPARK: Simple Post-training for Adapting pRetrained Knowledge to Robot Control](https://robotics.world/paper/spark-simple-post-training-for-adapting-pretrained-knowledge-to-robot-2611.12102) 2026-11-09 · cs.RO · Also by Sungjoon Choi
- [Force-Aware Reinforcement Learning with Hybrid Sensorless Force Estimation for Wheeled-Legged Loco-Manipulation](https://robotics.world/paper/force-aware-reinforcement-learning-with-hybrid-sensorless-force-2609.13779) 2026-09-12 · cs.RO · Key terms of the title in common
- [Learning Force-Reactive Humanoid Loco-Manipulation](https://robotics.world/paper/learning-force-reactive-humanoid-loco-manipulation-2610.35862) 2026-10-26 · cs.RO · Key terms of the title in common
- [Differentiable Iterative Learning Control for Black-Box Position-Commanded Manipulators](https://robotics.world/paper/differentiable-iterative-learning-control-for-black-box-position-2611.01220) 2026-10-31 · cs.RO · Key terms of the title in common
- [ForceLDM: A Force-aware Latent Dynamics Model for Contact-Rich Manipulation](https://robotics.world/paper/forceldm-a-force-aware-latent-dynamics-model-for-contact-rich-2611.03294) 2026-11-02 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/proprioceptive-finger-force-estimation-for-reliable-box-manipulation-2610.38351
