# Real-time Estimator of Actuator Control and Health (REACH) on an Eel-Inspired Soft Robot

Robotics.world

> Soft underwater robots are built from compliant silicone materials and driven by soft actuators that degrade, tear or lose pump performance over long missions, but their behavior is hard to model, so…

**arXiv**: 2608.14865

**Published**: 2026-08-14 · revised · 2026-10-07

**Authors**: Zhangjingyi Jiang, Myungsun Park, Michael T. Tolley, Mark Campbell

## In plain words

Soft underwater robots are built from compliant silicone materials and driven by soft actuators that degrade, tear or lose pump performance over long missions, but their behavior is hard to model, so health cannot be monitored with the binary fail/no-fail logic used for rigid actuators.

## AI summary

## Overview

- **Research area:** Soft robotics and underwater robotics, specifically actuator fault detection and health estimation for bio-inspired swimming robots.
- **Technical level:** Advanced. The paper combines a nonlinear finite-element/hydrodynamics simulator, a sigma point Kalman filter, and a chi-squared statistical consistency test.
- **Scope:** The paper presents REACH, a real-time estimator that infers how much each soft actuator on an eel-inspired swimming robot has degraded, and evaluates it in simulation across sensor types, sensor placements and gaits, and in experiment on a three-actuator robot fish.

## What This Paper Is About

Soft underwater robots are built from compliant silicone materials and driven by soft actuators that degrade, tear or lose pump performance over long missions, but their behavior is hard to model, so health cannot be monitored with the binary fail/no-fail logic used for rigid actuators. The authors define "actuator health" as the ratio of actual to desired actuator torque output, where zero is full failure, one is full functionality, and above one is over-actuation, and they build an estimator that recovers this ratio in real time from onboard sensors. The goal is to let a soft swimming robot know how well each of its actuators is still working, quickly and accurately enough to complete a mission or return to base.

## Key Contributions

1. **A complete health-estimation architecture (REACH):** a sensor set, a sigma point Kalman filter built on the Anguilliform Swimming Soft Robot Simulation Platform (ASSRSimP) model, and a formal statistical hypothesis test for filter validation.
2. **A comparison of sensor modalities:** GPS, IMU and internal bend sensors are compared as inputs to actuator health estimation, with one sensor placed on each of five simulated actuators.
3. **A sensor quantity and placement study:** four sensor quantities with five to ten placement variations each are evaluated for IMU and for bend sensor, identifying minimum configurations for accurate estimation.
4. **Experimental validation on hardware:** the estimator is validated using bend sensor data from a three-actuator soft robot fish swimming underwater across nine distinct actuator health conditions, accounting for noisy data and manufacturing variation between actuators.

## Main Findings

- **GPS is unsuitable:** with GPS measurements, REACH could not detect any of the five simulated actuator failures within the three-second window; estimates converged toward the true health after 30 seconds in some simulations but diverged in others.
- **IMU and bend sensors both work:** both detected all actuator failures within three seconds. The bend sensor had lower RMS error for most failure cases and a lower rise time for actuator five failure, but a higher rise time than the IMU for failures in actuators one through four.
- **IMU needs fewer sensors:** two IMU sensors placed at actuators A1 and A4 were sufficient for "excellent" actuator health estimation, whereas three bend sensors placed at A2, A4 and A5 were needed.
- **Bend sensors are local:** bend sensors performed well at estimating the health of the actuator they sit on but often failed to estimate the health of actuators without sensors; overall the IMU outperformed the bend sensor in the placement study.
- **Gait has little effect:** for linear swimming, wide turning and tight turning, RMS error and rise time showed no significant difference across the three control algorithms, each simulated five times.
- **The filter is statistically consistent:** with a false positive rate of 5 percent, the validation statistic fell inside its lower and upper bounds around 95 percent of the time for the GPS, IMU and bend sensor estimators.
- **Experimental estimation works, with offsets:** REACH estimated actuator health from real bend sensor data in most of the nine trials, with a slight offset in some trials for partially or fully functioning actuators. Failures were predicted well, and the first few seconds of error were attributed to the fluid pump ramping up.
- **Oscillations are likely measurement lag:** the oscillatory pattern of the experimental health predictions resembled the simulated ones but with a slight time delay in the measurements, which the authors believe explains the oscillation.

## Methodology in Plain English

The team treats actuator health as an extra unknown in the robot's state and lets a filter infer it from sensor readings. The prediction model is an existing simulator (ASSRSimP) that represents the fish as a free-floating elastic beam with a nonlinear hydrodynamics model. A swimming gait is produced by feeding each actuator a sinusoid with an amplitude, a phase shift and a torque offset; multiplying each torque input by a health value simulates a degraded or failed actuator, and the health values are appended to the state vector.

Because the simulator is nonlinear and Jacobians are hard to compute, the authors use a sigma point Kalman filter, which propagates a small set of weighted sample points through the nonlinear dynamics and output equations to recover means and covariances without analytic derivatives.

To make sure the filter's tuning is honest, they use a filter validation method: the average normalized innovation squared over a window of N timesteps is compared against two-sided chi-squared thresholds for a chosen false positive rate. Values inside the bounds mean the filter is consistent; too high means biased; too low means over-conservative. This is used both to tune process and measurement noise and to confirm consistency, and it is described as more robust than simple sensor gating of single outliers.

Performance is scored on two axes. Rise time measures timeliness: how long until the health estimate comes within 0.1 of the true health. RMS error over the last 100 timesteps (one second) of each ten-second simulation measures accuracy. These are binned into excellent, good, acceptable and poor categories using rise time and RMS error thresholds.

For the experiment, the robot fish was tethered to external pumps and its three actuators' bend sensors were wired to a microcontroller. Eight markers were tracked by a camera aimed at a mirror beneath the tank, giving a bottom-up view at 12 Hz. Bend angles were computed from four marker positions around each actuator via an arctangent formula, and a quadratic fit (MATLAB `fit()`) mapped bend sensor readings to bend angles. The simulator was then reconfigured to match the physical fish as seven segments (three actuators, head, tail, two connections, four elements each), with plastic-modelled head and connections and rubber-modelled actuators whose stiffness was individually scaled to match the real hardware.

## Why This Matters

For soft robotics research, this is a step toward treating compliance as something that can be monitored rather than only actuated. Previous actuator health monitoring relied on model-based conditional logic or machine learning classifiers that output binary or discrete labels, which the authors argue cannot capture the continuous, time-varying behavior of soft actuators. REACH instead produces a continuous health value plus a variance, and it brings a statistical consistency test into soft-robot estimation, giving a principled way to know whether the estimator itself can be trusted.

- **Long-duration underwater missions:** an autonomous underwater vehicle that can tell it is losing an actuator can abort, adapt its gait, or return to base instead of failing silently, avoiding complex and expensive retrieval.
- **Environmental monitoring and exploration:** robots sent to remote or harsh underwater areas where human access is difficult benefit from onboard self-diagnosis rather than relying on operator inspection.
- **Predictive maintenance for soft machines:** the same health-ratio framing could flag material degradation, pump wear or power-supply instability before a hard failure, since the authors define health to encompass all three.
- **Sensor selection for soft robots:** the sensor type, count and placement comparisons give designers concrete guidance on what to embed, including the finding that internal bend sensors are inherently local while inertial sensing is more global.

**Industry relevance:** the work speaks to anyone commercializing soft or bio-inspired robots, where the cost of a failed mission is high and where the trade-off between number of sensors and estimation quality directly affects bill of materials and wiring complexity. The demonstration that two IMU sensors can be sufficient, versus three bend sensors, is a practical design signal. The statistical validation method is also transferable to other nonlinear field-robotics estimators where ground truth is unavailable.

## Future Directions

- **Closing the loop:** the paper estimates health but does not use it to reconfigure the swimming gait. Feeding the health estimate back into the control law to compensate for a degraded actuator is the obvious next step.
- **Explaining and removing the experimental offsets:** partially functioning actuators showed an offset in some trials, which the authors suspect comes from the actuator not starting at the neutral position. Better initial-condition modeling could tighten absolute health values, not just failure detection.
- **Resolving the measurement time delay:** the oscillatory behavior of the predictions is attributed to a slight delay in measurement data; characterizing and compensating for that lag would improve experimental accuracy.
- **Richer failure scenarios and field deployment:** the experiments covered nine health conditions on a single three-actuator fish with actuator A1 chosen as the main degraded actuator because it has the most impact on swimming. Multiple simultaneous degradations, longer missions, and IMU-based validation on hardware remain open.

## Target Audience

Graduate students and researchers in soft robotics, field robotics and state estimation who are interested in fault detection for systems that resist clean modeling; robotics engineers designing sensor suites for compliant or bio-inspired underwater vehicles; and practitioners who need a statistically defensible way to validate a nonlinear filter when ground truth is scarce. Readers without background in Kalman filtering or finite-element modeling will find the results section accessible but the method sections demanding.

## Authors’ abstract

An actuator health estimation algorithm for a soft swimming robot that can perform anguilliform swimming is developed. Due to harsh operational environments of underwater robots, and the common degradation of soft robot materials and actuators, accurate estimation of actuator functionality is necessary for robots to perform their missions as well as return to base in the event of actuator degradation and failure. Termed REACH (Real-time Estimator of Actuator Control and…

[The full abstract on arXiv](https://arxiv.org/abs/2608.14865)

[Read the original paper](https://arxiv.org/abs/2608.14865)

## Related papers

- [A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits](https://robotics.world/paper/a-task-agnostic-control-strategy-for-dynamic-assistance-with-2608.18364) 2026-08-18 · cs.RO · Also by Michael T. Tolley
- [VGFM: Expressive Robot Policies via Dense Value Guidance in Flow Matching](https://robotics.world/paper/vgfm-expressive-robot-policies-via-dense-value-guidance-in-flow-matching-2609.14261) 2026-09-13 · cs.RO · Also by Mark Campbell
- [Learning Communication-Conditioned Generative Policies for Decentralized Multi-Agent Collision Avoidance](https://robotics.world/paper/learning-communication-conditioned-generative-policies-for-2609.14268) 2026-09-13 · cs.RO · Also by Mark Campbell
- [Interpretable Collision Avoidance and Feasibility Guarantees through an Uncertainty Aware Pipeline](https://robotics.world/paper/interpretable-collision-avoidance-and-feasibility-guarantees-through-an-2610.33186) 2026-10-23 · cs.RO · Also by Mark Campbell
- [Joint-Health-Aware Reinforcement Learning for Robust Robot Control Under Actuator Degradation](https://robotics.world/paper/joint-health-aware-reinforcement-learning-for-robust-robot-control-2610.41348) 2026-10-30 · cs.RO · Key terms of the title in common

---