Research
Runtime Safety and Emergency Stops on a Full-Size Humanoid: Deployment Lessons and a Case for Graduated Force Authority
Full-size humanoids are being considered for hazardous work such as disassembling electric-vehicle battery packs, but a 70 kg machine that must actively balance becomes dangerous the moment it is…

- arXiv
- 2611.15928 · Preprint · not peer-reviewed
- Published
- 2026-11-11
- Authors
- Max Conway, Yutong Zhang, Allen Devaraj, William Xie, Alessandro Roncone, Nikolaus Correll
In plain words
Full-size humanoids are being considered for hazardous work such as disassembling electric-vehicle battery packs, but a 70 kg machine that must actively balance becomes dangerous the moment it is commanded to stop.
AI summary
Overview
- Research area: Runtime safety for full-size humanoid robots, with a focus on emergency-stop behavior, joint-limit enforcement, and the governance of physical force in industrial deployment.
- Technical level: Intermediate. The robotics content (ROS 2 stacks, model-predictive control, learned policies, e-stop categories) is explained at a level accessible to engineers and graduate students; the argument draws on developmental psychology and responsibility research in addition to engineering.
- Scope: An extended abstract reporting deployment lessons from the safety layer and emergency stop of the open-source Golem autonomy stack on a Unitree H1-2 humanoid, plus a proposal for granting robots force authority in stages tied to an explicitly responsible party.
What This Paper Is About
Full-size humanoids are being considered for hazardous work such as disassembling electric-vehicle battery packs, but a 70 kg machine that must actively balance becomes dangerous the moment it is commanded to stop. The authors describe the safety layer and e-stop in their open-source stack for the Unitree H1-2, report what happened when they pushed the standing robot until it lost balance, and show that a hard stop removes balance control and causes a fall that can be more hazardous than the event that triggered it. They then argue, using research on responsibility and on child and adolescent development, that a robot's authority to apply force should be widened in stages rather than fixed by torque limits alone.
Key Contributions
- A runtime safety layer that runs as an independent process between the control modules and the motors, enforcing joint position, velocity, and torque limits at 90% of the vendor specification and treating stale state estimates or lost heartbeats as faults — with deployment observations showing that the layer's own limits can trigger a hazardous stop.
- An emergency stop design (an Arduino Uno polling a physical e-stop, where losing contact with the Arduino is itself a stop condition) together with push trials in which the robot lost balance and needed the stop, and an analysis of why stopping a humanoid is itself a hazard that industrial stop categories do not address.
- A case for graduated force authority: because force limits do not settle whether a force should be applied, the authors argue — drawing on developmental psychology and research on responsibility — that force authority be widened in stages and tied to a responsible party.
- A set of partial engineering answers to the stopping problem: a stop hierarchy, a minimal verifiable balance fallback, and physical restraint until those exist.
Main Findings
- Stopping is not a safe state on a balancing robot. The H1-2 stays upright only because a controller running at 50–67 Hz keeps it there. The e-stop is a Category 0 stop that switches motor torque off, removing that controller, so the robot — with its center of mass about 0.9 m above the floor — collapses and releases roughly 600 J into whatever it hits first. By comparison, the 35 kg Unitree G1 with its center of mass scaled to 0.67 m would release about 230 J.
- The operator had to intervene in every MPC trial. Under the sampling-based MJPC controller, the center-of-mass margin decreased steadily to −0.166 m with a peak pitch lean of 16.3 ± 6.3°, and the e-stop was pressed in every trial, at 4.68 ± 2.86 s after the push (15 trials).
- The learned controller recovered. The adversarially trained ALMI policy reached a minimum margin of −0.044 m with a peak lean of 6.8 ± 1.4° and recovered a positive margin in 14 of 15 trials without intervention. Both controllers ran behind the same interface and the same safety layer, isolating the lower-body controller as the difference.
- Push forces were comparable. Mean peak push force was 20.4 ± 7.0 N for MJPC and 22.1 ± 6.9 N for ALMI, applied with a rod instrumented with an ATI Mini45 six-axis load cell.
- The stop worked only because the failure was slow. The e-stop decision was made by a person watching the robot lean, with a reaction time of seconds.
- Choosing joint limits is non-trivial. No single reliable set of limits for the H1-2 is available: the vendor's own walking policy sometimes exceeds the velocity and torque limits in the released URDF, so enforcing those limits as written would stop the robot during the vendor's own walking behavior.
- A limit intended for manipulation trips during walking. An elbow torque cap added to limit how hard the arm pushes exceeded during footstrike torque spikes; the safety layer would then trigger the e-stop although the arm touches nothing, switching torque off on all motors, including the legs, mid-stride.
- The 90% margin is a convention, not a hazard analysis. The 10% margin below the manufacturer's maximum values was not derived from hazard analysis.
- Force limits do not encode intent. Disassembly is forceful by nature; in the authors' screw-removal trials, all five failures began with off-axis extraction, after which the grasp force was too low to overcome the resulting friction. A rule such as "never exceed 32 N" blocks both harm and screw removal.
- Value-alignment safeguards trade helpfulness against harm. In the cited grasp-force study, a simple safeguard reduced harmful grasps from 67% to under 2% but also reduced helpful ones from 91% to 45%.
- A designated safe response caused most of the harm in a robotaxi crash. A Cruise robotaxi struck a pedestrian at 30 km/h, classified the event as a side impact, and began a pullover to a "minimal risk condition" 0.05 s later, dragging her 6 m before wheel slip triggered a stop; her legs were visible in a side camera throughout but were not tracked.
- Attempting a stop beats always damping, in simulation. In a cited simulation study on a smaller humanoid, always damping produced catastrophic contacts in 5.4% of episodes, compared with 1.4–1.7% when a stop was attempted.
- Grasp success degrades along a capability ladder. In the Golem evaluation, the robot is first hoist-tethered, then free-standing, then standing after navigating to the pack, and grasp success falls from 97% to 87% to 37% across these rungs.
Methodology in Plain English
The authors built a safety layer as a separate low-level process that every joint command must pass through before reaching the motors. It continuously compares measured joint positions, velocities, and torques against configured limits set at 90% of the manufacturer's maximums, and it stops the robot if any limit is exceeded, if the state estimate goes stale, if a heartbeat is lost, or if it loses contact with a microcontroller attached to a physical e-stop button. They made the layer independent of the modules above it because those modules include a learned policy whose failure modes cannot be enumerated and a sampling-based optimizer whose output depends on an estimated base velocity.
To test what happens when balance fails, they pushed the standing robot slightly above the center of the torso with an instrumented rod until its center of mass left its support polygon, and compared two lower-body controllers — sampling-based model-predictive control (MJPC) and a learned policy (ALMI) — running behind the same interface and safety layer, 15 trials each. An overhead safety line caught the robot in every fall, so the trials did not measure what a fall damages.
They then reviewed industrial stop categories (IEC 60204-1, ISO 13850) against the physics of a balancing humanoid, and reviewed developmental psychology and responsibility research (Piaget's heteronomous and autonomous morality, graduated driver licensing, scaffolding, entrustable professional activities) to build a vocabulary for granting force authority in stages.
Why This Matters
- Research impact. The paper reframes the emergency stop as a design problem in whole-body balance rather than a solved safety primitive, and argues that joint limits and stop behavior cannot be designed separately — a point that bears directly on how safety layers are specified for legged and humanoid platforms. It also names a concrete standards gap: ISO/CD 25785-1, under development for industrial mobile robots with actively controlled stability, is identified as the natural place to define a stop hierarchy.
- Battery disassembly. Packs weigh about 450 kg, carry up to 800 V, arrive in an unknown state of charge, and can enter thermal runaway or electrocute workers; a fall onto exposed cells could start exactly the thermal runaway that robotic disassembly is meant to prevent.
- Human–robot shared workspaces. Because the e-stop removes balance control and drops a 70 kg machine near the operator who pressed the button, the person closest to the robot is exposed to the consequence of the stop.
- Safety certification and liability. The argument that force authority should widen only with a named responsible party bears on how integrated humanoid systems — not just individual components — are certified and insured.
- Industry relevance. The finding that the only recovering controller in the stack was the learned one, which the authors cannot certify, exposes a direct tension between demonstrated performance and certifiability for anyone deploying humanoids industrially.
Future Directions
- Define and implement a stop hierarchy. A freeze that keeps the lower-body controller running with a zero-velocity command when the hazard is the arm, a controlled descent to a kneel or sit when the hazard is the base, and damping as the last level — with power cut only when the robot is restrained or already on the ground.
- Build a minimal, verifiable balance fallback. For example, control barrier functions on center-of-mass margin and joint torque around a crouch-and-kneel primitive, small enough to analyze, so safety does not rely on the learned policy's recovery.
- Use the digital twins to test stop logic first. The twins expose the same ROS 2 interfaces as the hardware, so the safety layer and stop logic could be compared against learned-stop methods in simulation before repeatedly dropping a 70 kg robot.
- Turn the capability ladder into task- and context-dependent force envelopes. Start conservative, widen only for contact modes the system has shown it can recognize, and return to the conservative default when perception reports low confidence, a person enters the workspace, or the task changes — recording, for each widening, the person or organization responsible. Open questions remain about who answers for the integrated system when the vendor's walking policy and its released limits disagree.
Target Audience
Roboticists deploying legged or humanoid hardware outside the lab; safety engineers and standards contributors working on stop categories and mobile manipulator safety; researchers working on whole-body control, fall recovery, and learned policies for physical interaction; and policy, legal, and ethics researchers interested in how responsibility for a robot's use of force might be assigned in practice.
Authors’ abstract
Full-size humanoid robots are being considered for hazardous industrial work such as disassembling electric-vehicle batteries. We describe the safety mechanisms of an open-source autonomy stack for the Unitree H1-2 humanoid and what deploying them taught us. All joint commands pass through a safety layer that runs separately from the control software. It enforces joint position, velocity, and torque limits, and it stops the robot when a state estimate becomes stale or when…
The full abstract on arXivRelated papers
- GOLEM: Modular Humanoid Autonomy Towards Electric Vehicle Battery Disassembly 2026-08-21 · cs.RO · Also by Alessandro Roncone, Allen Devaraj +4
- Leaning Over to Reach Far-Away Objects 2026-11-14 · cs.RO · Also by Allen Devaraj, Nikolaus Correll +1
- Toward Geometry-Scalable Whole-Body Touch for Humanoids: A 3D-Printed Conformal EIT Skin 2026-08-03 · cs.RO · Also by Alessandro Roncone
- Compliant Sphere Lattice Contact: Distributed Contact Modeling for Sphere-Based Robot Representations 2026-07-31 · cs.RO · Also by Alessandro Roncone