Research
Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma
Uncontrolled bleeding is a leading cause of preventable trauma death, and timely expert intervention is often unavailable. Existing autonomy research on hemorrhage control has focused almost entirely…

- arXiv
- 2611.00237 · Preprint · not peer-reviewed
- Published
- 2026-10-30
- Authors
- Francis Fan, Mackenzie A Eagleson, Yvonne Zhang, Hongting Pan, Lujia Yang, Ethan Kilmer, Jiawei Ge, Nural Yilmaz, Avinash Dhimal, Ahmed Ghazi, Jeffrey Jopling, Laura Connolly, Axel Krieger
In plain words
Uncontrolled bleeding is a leading cause of preventable trauma death, and timely expert intervention is often unavailable. Existing autonomy research on hemorrhage control has focused almost entirely on one maneuver — robotic suction — and mostly on synthetic phantoms rather than clinically realistic tissue.
AI summary
Overview
- Research area: Surgical robotics / autonomous medical intervention — specifically supervised autonomous bimanual manipulation for hemorrhage control, combining computer-vision perception with robot motion control.
- Technical level: Intermediate. The paper assumes familiarity with laparoscopic robotic platforms (dVRK), segmentation models, keypoint tracking, and visual servoing, but every component is described well enough for a non-specialist to follow the logic.
- Scope (1 sentence): The paper presents and evaluates a supervised autonomous two-arm robotic system that uses camera-based perception to suction blood and cauterize low-grade splenic injuries on a perfused ex vivo porcine spleen model.
What This Paper Is About
Uncontrolled bleeding is a leading cause of preventable trauma death, and timely expert intervention is often unavailable. Existing autonomy research on hemorrhage control has focused almost entirely on one maneuver — robotic suction — and mostly on synthetic phantoms rather than clinically realistic tissue. This paper closes part of that gap by building a system that both clears blood with suction and then applies electrocautery to the wound surface, and by testing it on a novel perfused ex vivo spleen model that bleeds under physiological-analog pressure.
Key Contributions
- A perfused ex vivo splenic hemorrhage model: porcine spleens with cannulated splenic artery and vein, a custom synthetic blood perfusate, and controlled AAST Grade I–II lacerations, used for data collection, validation, and testing.
- A vision-only perception pipeline that localizes the injury via bleeding segmentation, tracks both instruments with markerless keypoint detection, and infers tool–tissue contact from laparoscopic video — with no explicit 3D sensing.
- A supervised autonomous bimanual workflow in which two dVRK-Si patient side manipulators coordinate suction and monopolar cauterization along a planned wound trajectory, with a human supervisor approving the injury segmentation before motion begins.
Main Findings
- Cauterization coverage: Across 5 simulated Grade I and 2 simulated Grade II injuries on an unseen spleen, the system achieved an average bleeding surface cauterization coverage of 82.9%. 4/7 injuries reached 97% or more coverage.
- Per-injury spread: Coverage was 98.69% (Injury 1), 98.74% (Injury 2), 67.89% (Injury 3), 67.85% (Injury 4), 100% (Injury 5), 97.89% (Injury 6), and 49.38% (Injury 7). Injuries 3, 4, and 7 fell below 70%.
- Bleeding segmentation performance: The nnU-Net detected bleeding in 98% of frames in which it was present (n = 297), with median Dice 0.69 and median HD95 36.6 px. Sensitivity (0.77) exceeded precision (0.58), indicating a tendency to over-segment.
- Tool tracking performance: On 127 held-out frames, the DeepLabCut-based tracker achieved mAP 93.76% and mAR 95.51%, with RMSE 4.28 pixels for predictions above 0.6 confidence.
- Contact detection performance: Grouped five-fold cross-validation gave a mean contact F1 of 0.738, with fold values from 0.691 to 0.782.
- Contact-detection bias: The classifier produced false positives above textureless blood pools, most visibly during vertical descent. The authors attribute this to a distribution mismatch: training footage came largely from an expert surgeon approaching laterally, while the autonomous controller descends more vertically.
- Tracking failure conditions: Cautery hook keypoints lost confidence during coagulation due to smoke, electrical arcing, and partial immersion in blood; suction tool tracking was more stable but degraded at steep wrist angles.
- Depth-related failure modes: Without 3D surface reconstruction, planned trajectories are planar and cannot follow depth variation along the wound. On Injury 4, tissue scarring occurred as the hook exited the wound; on Injury 7 (Grade II), the hook got stuck inside the laceration.
- Metric caveat: Coverage measures geometric treatment of the wound surface and does not by itself establish hemostatic efficacy; clinical measures such as the VIBe score were not used.
Methodology in Plain English
Building a bleeding model. The team took porcine spleens, sewed off small vessel branches, and inserted cannulas into the main splenic artery and vein. They pumped a synthetic blood substitute through the organ in a closed loop — a mixture of liquid egg whites (a protein that visibly coagulates when heated), saline for electrical conductivity, glycerol to match blood viscosity, and red and blue food dye for appearance — heated to 37°C and held at a target pressure of 65–110 mmHg. Cuts were made with a #11 blade marked at 1 cm intervals so injury depth, and therefore AAST grade, could be reproduced consistently.
Teaching the robot to see. Three separate models share one camera feed. An nnU-Net segments pooled blood; a simple geometric rule then converts the mask into an estimated wound line and a candidate bleeding source. DeepLabCut tracks nine keypoints across the two instruments (four on the cautery hook, five on the suction tool), with automatic fallback points when confidence drops below 0.6. A third model, an EfficientNet-B0 binary classifier, looks at a cropped region around the tools and decides whether a tool is touching tissue. Training data came from an expert surgeon treating simulated injuries on 2 ex vivo spleens, annotated in CVAT.
Controlling the arms. Lateral motion uses image-Jacobian visual servoing: pixel error between tool and target is mapped to millimetres of robot motion via a damped least-squares update. Once aligned, the arm descends slowly in a contact-only mode, with no absolute depth estimate — it simply moves down at 0.75 mm/s until the contact classifier reports contact. The suction arm sweeps along the wound centerline; the cautery arm then executes precomputed fixed-orientation strokes, lifting 2 mm between passes. A human supervisor confirms the segmentation and activates autonomy, and a person at the console presses the electrocautery pedal for each pass — energy activation is deliberately not automated.
Measuring success. After treatment, cauterized area was compared against the target wound mask pixel by pixel, and the percentage of wound surface covered was reported, alongside qualitative overlays for covered target, untreated wound, and off-target coagulation.
Why This Matters
- Impact on research: The paper moves hemorrhage-control autonomy from a single maneuver (suction) on simplified phantoms toward two coordinated maneuvers on perfused, bleeding tissue. It also contributes an explicitly supervised autonomy formulation, framed as a necessary safety-critical intermediate step rather than a claim of full autonomy.
- Real-world applications:
- Battlefield and pre-hospital casualty care, where most injury deaths occur before reaching a treatment facility.
- Austere or rural settings where a trained surgeon is not physically present but a robotic system and a supervising clinician could be.
- Intraoperative assistance during long procedures, where uncontrolled bleeding is the leading proximate cause of intraoperative death.
- A training and rehearsal platform for surgical residents, using a reproducible perfused model rather than live animals.
- Industry relevance: The work is built on the da Vinci Research Kit (dVRK) Si platform with two patient side manipulators and a custom 3D-printed suction attachment for ProGrasp forceps, showing how commercial surgical hardware can be extended with perception-driven autonomy. The supervised-autonomy framing and the explicitly manual energy gating map onto the kind of incremental, human-oversight regulatory pathway that surgical robotics companies must follow.
Future Directions
- 3D surface reconstruction: Replacing the planar trajectory assumption with real depth sensing so the cautery hook can follow wound profile variation, which the authors identify as the likely cause of the sub-70% coverage on Injuries 3, 4, and 7.
- Better contact detection under blood and occlusion: Adding training examples with shallow contact, hovering above blood, reflections, and vertical descent to remove the false-positive bias, plus more keypoint annotations for smoke, arcing, and submerged tools.
- Faster perception: Optimizing inference so the perception loop keeps pace with the 30 Hz video stream, which the authors say is needed to test the system under continuous blood flow rather than the reduced flow the current speed allows.
- Clinically meaningful evaluation: Moving from geometric coverage to hemostatic endpoints such as the VIBe score, combined with automatic pressure-flow regulation and closed-loop control based on measured bleeding reduction.
Target Audience
Robotics and computer-vision researchers working on surgical autonomy, medical image segmentation, or vision-based manipulation; surgical robotics engineers evaluating supervised-autonomy architectures on real hardware; and clinician-scientists in trauma and acute care surgery interested in what current autonomous systems can and cannot yet do at the tissue level. Graduate students entering the field will find the paper useful as a clear template for combining off-the-shelf perception models into a closed-loop bimanual pipeline, including an unusually candid account of where each component fails.
Authors’ abstract
Uncontrolled hemorrhage remains a leading cause of preventable trauma mortality. Timely intervention is not always available, making autonomous systems that can aid in bleeding control a promising alternative. Given the safety-critical nature of the task, supervised autonomy, in which the system executes the technical steps while a human retains oversight, represents a necessary intermediate step toward this goal. In this work, we present a supervised autonomous bimanual…
The full abstract on arXivRelated papers
- ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery 2026-11-11 · cs.RO · Also by Ethan Kilmer, Francis Fan +2
- Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy 2026-09-14 · cs.RO · Also by Ahmed Ghazi, Ethan Kilmer +2
- An Open-Source da Vinci X/Xi Instrument Module for Laparoscopic Surgery Research 2026-11-16 · cs.RO · Also by Jiawei Ge, Mackenzie A Eagleson +1
- Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection 2026-10-20 · cs.RO · Also by Ethan Kilmer, Jiawei Ge
- Revisiting Direct Control: A Field Evaluation of Sensor Fusion Efficacy in Teleoperating Full-Scale Autonomous Vehicles via Bird's Eye View 2026-10-26 · cs.RO · Key terms of the title in common