# Surgical Re-enactment for Operating Room Workflow Datasets

Robotics.world

> AI systems for the "smart" operating room need to understand the whole surgical workflow — the coordinated actions of all OR personnel, not just the surgeon — and that requires realistic…

**arXiv**: 2607.24206 · accepted · ICRA workshop

**Published**: 2026-07-27

**Authors**: Jana Nina Friedrich, Andrea Karin Maria Ross, Angelo Henriques, Mario Peter Martin Weisser, Ling Zhang, Mohammad Ali Nasseri

## In plain words

AI systems for the "smart" operating room need to understand the whole surgical workflow — the coordinated actions of all OR personnel, not just the surgeon — and that requires realistic multi-person, multi-camera data. Collecting such data inside real ORs is prohibitively difficult because of ethics approvals, limited space for cameras, sterility rules that forbid tracking markers, and poor lighting.

## AI summary

## Overview

**Research area:** Surgical robotics and operating-room AI — specifically, methods for building annotated multi-person surgical workflow datasets. **Technical level:** Intermediate. The paper is a methodology/protocol paper with no heavy mathematics; it assumes familiarity with concepts such as activity recognition, scene graphs, surgical process models and BPMN, but explains its own procedure step by step. **Scope (one sentence):** The paper presents and demonstrates an eight-phase, reproducible protocol for re-enacting complete surgical procedures in a reconstructed operating room so that realistic, annotatable workflow datasets can be recorded without the constraints of a live clinical OR.

## What This Paper Is About

AI systems for the "smart" operating room need to understand the whole surgical workflow — the coordinated actions of all OR personnel, not just the surgeon — and that requires realistic multi-person, multi-camera data. Collecting such data inside real ORs is prohibitively difficult because of ethics approvals, limited space for cameras, sterility rules that forbid tracking markers, and poor lighting. The paper's goal is a step-by-step, transferable method for re-enacting full procedures in a reconstructed OR, developed for robot-assisted ophthalmic surgery, that yields repeatable, annotatable data for training activity recognition models, generating scene graphs and formalizing surgical process models.

## Key Contributions

1. An eight-phase re-enactment methodology — expert consultation, initial workflow, role assignment, OR reconstruction, role training, OR observation, final preparation, and recording (with post-take debriefing) — in which a single clinical expert is embedded in every phase rather than only consulted at the start.
2. A new "director" role that does not exist in real ORs: the director does not act in the re-enactment but observes each take and documents deviations from the workflow, errors or hesitations, and other notable events, which simplifies later annotation and drives the iterative debrief loop.
3. A concrete demonstration in robot-assisted ophthalmic surgery: 10 complete re-enactments recorded over multiple days, using five synchronized RGB-D camera perspectives, and reported as supporting activity recognition, scene graph generation, and BPMN-based surgical process models.
4. Concrete recommendations intended to let other research groups adopt the methodology in their own surgical domains, plus an explicit comparison against prior OR datasets (Cholec80, Sharghi et al.'s 400 multi-perspective videos, and 4D-OR) explaining what those datasets do not provide.

## Main Findings

- **Recording output:** 10 complete re-enactments of an ophthalmic surgical procedure were captured over multiple recording days.
- **Team size and roles:** each recording involved six people covering seven roles, with one person performing two non-overlapping roles.
- **Take duration:** recordings ranged from 30 to 44 minutes, with early takes longer because of timing errors, corrections of missed steps, and problems such as incorrect instrument handling or breaking the sterile field.
- **Iterative improvement:** quality improved substantially through the post-take debrief loop, so later takes became more efficient and required fewer corrections.
- **Expert judgment of fidelity:** the clinical expert qualitatively assessed that the final recordings closely resembled real OR dynamics.
- **Deliberate variation:** to increase dataset diversity, selected takes included intentionally introduced variations such as a dropped instrument.
- **Gap in prior datasets:** Cholec80 captures only endoscopic views rather than the full OR scene; Sharghi et al. collected 400 multi-perspective OR videos during real robot-assisted surgeries but such institutional access is rare; 4D-OR uses simulated knee replacement surgeries for scene graph generation but does not describe its re-enactment methodology, making it hard to reproduce.
- **Validation status:** fidelity was assessed only qualitatively by the clinical expert; quantitative validation, for example using Dynamic Time Warping to compare against real OR logs, is stated as future work.

## Methodology in Plain English

The team turned surgery into a rehearsed production. First, an experienced surgeon walked the team through the entire procedure — preparation, surgical execution and cleanup — and stayed involved throughout the project to answer domain questions as they arose. From that walkthrough the team wrote a first draft workflow document containing a full equipment list, the professions to be captured, and all actions in chronological order, explicitly preserving actions that happen in parallel across roles.

Each team member was then assigned a role to play (for example surgeon, surgical assistant, anesthesiologist, runner, or cleaning staff), plus one person took the dedicated director role to log deviations, errors and notable events. The team measured the real OR after operating hours, produced a floor plan, and built a reconstructed OR fitted with RGB-D cameras, a microscope camera and microphones. Rather than rehearsing together immediately, each person trained their own role separately under the expert's real-time correction, then shadowed that role in live surgeries with a prepared list of open questions and structured note-taking.

Those observations fed back into the workflow document — adding missing steps, correcting timing, capturing communication patterns — followed by a complete end-to-end run-through. Only when the expert confirmed the team could perform the procedure consistently did recording begin. After each take, the director's notes and the expert's observations were discussed to find and fix errors, creating a fast improvement loop from take to take.

## Why This Matters

**Impact on research:** The paper addresses a bottleneck that limits work on surgical workflow recognition and surgical process modeling — the scarcity of realistic, fully annotated, whole-room data covering all personnel. By making the data-collection process repeatable and controllable, it gives groups without privileged OR access a route to such datasets, and it makes annotation easier because the structured workflow document and the director's log serve as ground truth.

**Real-world applications:**

- Training activity recognition and workflow recognition models that must reason about all OR staff, not only the surgeon.
- Generating scene graphs of the operating room for perception and situation-awareness systems.
- Formalizing surgical process models, including BPMN-based representations, for process analysis and optimization.
- Studying how surgical robots can be integrated into OR workflows before first real-time clinical applications are realized.

**Industry relevance:** Robot manufacturers and hospital IT vendors building context-aware OR systems need workflow-level training and evaluation data; re-enactment offers a controlled alternative to negotiating multi-camera access in active clinical sites, and permits deliberately injected rare events (such as a dropped instrument) that are hard to capture in genuine surgery.

## Future Directions

- Quantitative validation of re-enactment fidelity — the authors specifically name Dynamic Time Warping comparison against real OR logs as future work.
- Public release of the full annotated dataset, which the authors state is being prepared.
- Repeating the re-enactment with a full clinical team instead of researchers, which would raise fidelity but is hard to coordinate given OR personnel availability and scheduling.
- Transferring and validating the eight-phase methodology in surgical domains other than robot-assisted ophthalmic surgery, which the authors argue is feasible but do not demonstrate.

## Target Audience

Robotics and medical-AI researchers who need operating-room data for workflow recognition, activity recognition, scene graph generation or surgical process modeling, particularly groups without routine access to live OR recording. It is also useful for clinical collaborators and lab leads who need to understand what a re-enactment study demands — one committed clinical expert across all phases, an available room to reconstruct, a multi-camera capture setup, and a team willing to train individual roles and observe live surgeries before recording.

## Authors’ abstract

The introduction of new technologies, such as surgical robots, is driving the vision of a connected, smart operating room (OR). However, realizing this vision requires a deep understanding of surgical workflows, which relies on realistic datasets capturing the actions of all OR personnel from both full room and surgical field perspectives. Acquiring such data in real ORs is prohibitively challenging due to factors such as ethics committee approvals, limited space for camera…

[The full abstract on arXiv](https://arxiv.org/abs/2607.24206)

[Read the original paper](https://arxiv.org/abs/2607.24206)

## Related papers

- [Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing](https://robotics.world/paper/recording-hand-held-laparoscopic-instrument-motion-in-the-operating-2609.25577) 2026-09-22 · cs.RO · Key terms of the title in common

---