# Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection

Robotics.world

> Surgeons continuously adjust how fast they move an electrosurgical tool based on what they see, but autonomous cutting robots typically run open-loop at a speed chosen ahead of time by trial and…

**arXiv**: 2610.27562 · Preprint · not peer-reviewed

**Published**: 2026-10-20

**Authors**: Naveed D. Riaziat, Jiawei Ge, Ethan Kilmer, Michael W. Mikula, Paul Maria Scheikl, Michael Kam, Leila J. Mady, Axel Krieger, Jeremy D. Brown

## In plain words

Surgeons continuously adjust how fast they move an electrosurgical tool based on what they see, but autonomous cutting robots typically run open-loop at a speed chosen ahead of time by trial and error. That mismatch matters: cutting too slowly burns healthy tissue, while cutting too fast causes tissue snagging and inaccurate margins.

## AI summary

## Overview

**Research area:** Autonomous robotic surgery — specifically closed-loop control of electrosurgical soft-tissue cutting for head and neck tumor resection.

**Technical level:** Advanced. The paper combines robot motion planning, thermal imaging, online parameter estimation (a truncated unscented Kalman filter), scalar optimization, and blinded histological analysis.

**Scope:** An ex vivo porcine-tongue study comparing a thermal-feedback velocity-optimization algorithm (ThERMO) against two fixed cutting speeds on the UR10e-based ASTR robotic platform, evaluated by pathologist-graded thermal injury and photogrammetric margin accuracy.

## What This Paper Is About

Surgeons continuously adjust how fast they move an electrosurgical tool based on what they see, but autonomous cutting robots typically run open-loop at a speed chosen ahead of time by trial and error. That mismatch matters: cutting too slowly burns healthy tissue, while cutting too fast causes tissue snagging and inaccurate margins. The authors test whether a closed-loop algorithm that reads real-time thermal images and continuously re-optimizes cutting velocity can reduce collateral thermal damage *and* improve margin accuracy at the same time, without any data-driven training or manual speed tuning.

## Key Contributions

1. **First validation of ThERMO in biological tissue for 3D cutting** — prior work demonstrated the algorithm only in 2D hydrogel phantoms; this study runs it on a multi-degree-of-freedom robot (ASTR) cutting ex vivo porcine tongue.
2. **Histological quantification linking thermal feedback to actual cell death** — a board-certified pathologist, blinded to method, measured thermal injury extent on H&E-stained sections (n = 216 observations), establishing a connection between thermal sensing and cellular damage that had not previously been validated.
3. **Post-hoc margin verification against fixed-speed baselines** — 3D photogrammetric measurement using an independent sensor (Intel RealSense D405) yielded n = 3240 margin accuracy measurements across three cutting methods.
4. **A comparative study including blinded expert clinical rating** — a board-certified otolaryngologist rated anonymized image–video pairs on a 5-point scale for margin accuracy, thermal effects, and overall impression.

## Main Findings

- **Thermal injury reduced:** ThERMO produced an estimated marginal mean thermal injury extent (TIE) of **246.57 ± 70.68 μm**, versus **515.43 ± 64.34 μm** for the robot-derived fixed speed (RDFS, 2 mm/s) and **293.68 ± 58.62 μm** for the clinician-derived fixed speed (CDFS, 7 mm/s). The RDFS–ThERMO contrast (268.86 ± 47.12 μm) was significant at **p = 0.001**; the CDFS–ThERMO contrast (−47.11 ± 48.63 μm) was not significant (**p = 0.370**).
- **Margin accuracy improved:** Absolute margin error (AME) was **0.69 ± 0.23 mm** for ThERMO, **0.98 ± 0.23 mm** for RDFS, and **1.68 ± 0.23 mm** for CDFS. ThERMO was significantly better than CDFS (−0.99 ± 0.32 mm, **p = 0.022**); the RDFS–ThERMO difference was not significant (**p = 0.414**).
- **Signed margin error shows CDFS cutting too close to the tumor:** Mean signed margin error (SME) was **−1.68 ± 0.45 mm** for CDFS, **0.08 ± 0.45 mm** for RDFS, and **−0.36 ± 0.45 mm** for ThERMO. CDFS differed significantly from RDFS (1.76 ± 0.64 mm, **p = 0.033**) and did not differ significantly from ThERMO (**p = 0.084**). All three sat above the −2.2 mm "close margin" threshold marked in the paper's plots.
- **Speed was maintained:** Mean task completion times were **52.32 s** (RDFS), **18.83 s** (CDFS), and **22.16 s** (ThERMO). ThERMO and CDFS did not significantly differ; RDFS was the slowest, consistent with its lower commanded velocity.
- **Headline aggregate figures:** The abstract reports ThERMO reduced thermal injury by up to **52%**, improved cut accuracy by up to **59%**, and maintained task completion speed, all without data-driven training or iterative tuning.
- **Cut depth tracked the same ranking:** Against a commanded 5 mm depth, ThERMO achieved **4.13 mm**, RDFS **3.65 mm**, CDFS **3.20 mm**. Depth was a significant predictor of TIE (**p = 0.034**) at **32.1 μm/mm**.
- **Expert clinical rating agreed:** The blinded otolaryngologist rated ThERMO and RDFS higher than CDFS, which was downgraded for poorer margin control.

## Methodology in Plain English

The team used ten porcine tongues (nine cut, one histological control), chosen because porcine tongue tissue resembles human tongue. Each tongue was sutured to a grounding pad — mimicking how a surgeon tensions the tongue during a partial glossectomy — and scanned with the Zivid 2+ RGB-D camera to build a 3D surface map. A tumor outline derived from a real clinical tongue tumor scan was projected onto the surface, and a parallel contour 5 mm outside it defined the target cutting margin, matching clinical margin guidelines.

The robot oriented the tool so the thermal camera trailed the cutting edge (keeping the heat trail in frame) and the tool axis stayed normal to the tissue surface (avoiding perspective distortion of the measured isotherm width). The electrosurgical unit ran at 35 W in cut mode, as advised by an expert head-and-neck surgeon.

For ThERMO, the thermal camera streams a 384 × 288 image at 25 Hz. The algorithm thresholds each frame at 60 °C — the denaturation temperature — and computes a distance transform to get the isotherm width (a proxy for thermal injury) plus the hottest point (which reveals tool deflection, a proxy for cutting force via Hooke's law). A truncated unscented Kalman filter estimates unknown tissue parameters online (thermal conductivity, maximum cutting force, linear power density, specific heat), initialized from published IT'IS values. A scalar cost function balances squared cutting force against squared thermal width, plus a penalty for dropping below a nominal velocity and a smoothing term on velocity changes; SciPy's `minimize_scalar` (Brent's method) solves it in under a millisecond at every 30 Hz update. Setpoints are streamed to the UR10e at 125 Hz.

Two baselines were compared: 2 mm/s (the speed used in prior ASTR work) and 7 mm/s (measured from an expert surgeon's handheld device via external trackers). After cutting, tongues were fixed in formalin for 72 hours, and eight wedge-shaped blocks per tongue were sectioned into three 5 μm slices at 50 μm increments for H&E staining. Margin accuracy was measured photogrammetrically with an independent D405 camera by matching inner and outer contours by angle. Statistics used linear mixed models with method and depth as fixed effects and trial (and block, for thermal injury) as random effects.

## Why This Matters

**Impact on research:** The paper reframes autonomous electrosurgery as an optimal-control problem with competing objectives rather than a trajectory-following problem with a hand-tuned constant. It also provides the first histological ground truth connecting thermal camera readings to actual cellular damage in this setting — a validation step that prior thermal-feedback control work lacked.

**Real-world applications:**

- Partial glossectomy and other oral squamous cell carcinoma resections, where margins must reach 5 mm without excessive healthy-tissue loss.
- Trans-oral robotic surgery, where the confined oral cavity makes continuous surgeon monitoring of thermal spread difficult.
- Other electrosurgical soft-tissue procedures where an ESU is used for simultaneous cutting and hemostasis.
- Surgical training and skill assessment, since the 7 mm/s figure was derived from expert handheld motion and could serve as a benchmark.

**Industry relevance:** Directly relevant to surgical robotics companies pursuing autonomy (the paper cites the da Vinci Single Port and STAR), to electrosurgical unit manufacturers (the authors note most ESUs cannot modulate power in real time), and to thermal-camera makers moving into endoscopic form factors. The method requires no training data and no per-tissue retuning — attractive properties for regulatory and deployment pathways where generalizability across tissue types is a concern.

## Future Directions

1. **Cadaveric and in vivo studies.** The authors explicitly frame ex vivo testing as a critical intermediate step toward cadaver studies and eventual in vivo work, which would introduce blood perfusion and living-tissue thermal response absent from the current model.
2. **Full three-dimensional resection.** This study covers only the first peripheral cut — the step that determines margins — not the underside approach needed to complete a resection.
3. **Closing the deformation-and-thermal loop more tightly.** The paper notes that combining deflection feedback with thermal injury feedback had not been demonstrated before, and that soft-tissue simulation is neither patient-specific nor robust; extending online tissue-parameter identification to handle the muscular, tough tissue of the tongue more explicitly remains open.
4. **Generalization beyond the tested conditions.** All cuts used a single ESU setting (35 W, cut mode) and one tissue type; whether the online estimation holds across power settings, waveforms (coagulation vs. fulguration), and other soft tissues is untested.

## Target Audience

Robotics and surgical-automation researchers working on closed-loop control for soft-tissue intervention; head and neck surgeons and surgical oncologists interested in what autonomous electrosurgery can currently deliver; medical device engineers working on electrosurgical units or endoscopic thermography; and graduate students in medical robotics who want a concrete example of pairing online estimation with physical models and validating against blinded clinical pathology rather than proxy metrics alone.

## Authors’ abstract

Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue. Histological analysis was performed to detect…

[The full abstract on arXiv](https://arxiv.org/abs/2610.27562)

[Read the original paper](https://arxiv.org/abs/2610.27562)

## Related papers

- [Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma](https://robotics.world/paper/supervised-autonomous-bimanual-suction-and-cauterization-for-bleeding-2611.00237) 2026-10-30 · cs.RO · Also by Axel Krieger, Ethan Kilmer +1
- [ARTS: An Open-Source, Reproducible Three-Arm Platform for Autonomy Research in Minimally Invasive Surgery](https://robotics.world/paper/arts-an-open-source-reproducible-three-arm-platform-for-autonomy-2611.15135) 2026-11-11 · cs.RO · Also by Axel Krieger, Ethan Kilmer +1
- [Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy](https://robotics.world/paper/occupancy-network-guided-autonomous-robotic-partial-nephrectomy-2609.16186) 2026-09-14 · cs.RO · Also by Axel Krieger, Ethan Kilmer +1
- [An Open-Source da Vinci X/Xi Instrument Module for Laparoscopic Surgery Research](https://robotics.world/paper/an-open-source-da-vinci-x-xi-instrument-module-for-laparoscopic-surgery-2611.21771) 2026-11-16 · cs.RO · Also by Axel Krieger, Jiawei Ge
- [An Optimal Algorithm for Changing from Longitudinal to Latitudinal Formation of Autonomous Aircraft Squadrons](https://robotics.world/paper/an-optimal-algorithm-for-changing-from-longitudinal-to-latitudinal-2610.17511) 2026-10-13 · cs.RO · Key terms of the title in common

---

Canonical: https://robotics.world/paper/velocity-optimization-via-thermal-imaging-enhances-autonomous-tumor-2610.27562