Skip to content
Robotics.world

Research

StenoVLA-3D: 3D-Aware Reasoning VLA for Navigation Through Gastrointestinal Stenoses

Autonomous endoscopy must steer an instrument through narrowed regions of the gastrointestinal tract using monocular images that often lack texture, while also remembering lesions after they leave…

The paper’s first page · arXiv:2609.24187
arXiv
2609.24187 · Preprint · not peer-reviewed
Published
2026-09-21 · revised · 2026-09-22
Authors
Tamima Tabassum, Yiming Huang, Tianchun Wu, Changjing Liu, Zhiqing Tang, Chikit Ng, Beilei Cui, Liangjing Shao, Jiewen Lai, Hongliang Ren

In plain words

Autonomous endoscopy must steer an instrument through narrowed regions of the gastrointestinal tract using monocular images that often lack texture, while also remembering lesions after they leave the camera's view so that a clinical report can be produced at the end.

AI summary

Overview

Research area: Medical robotics and robot learning, specifically autonomous endoscopic navigation with vision-language-action (VLA) models.

Technical level: Advanced. The paper assumes familiarity with VLA architectures, LoRA fine-tuning, point-map/3D reconstruction models, and recurrent memory mechanisms.

Scope: The paper proposes StenoVLA-3D, a 3D-aware VLA framework that combines point-map geometry, temporal and persistent memory, and structured reasoning to navigate a robotic endoscope through gastrointestinal stenoses and to produce an episode-level lesion report.

What This Paper Is About

Autonomous endoscopy must steer an instrument through narrowed regions of the gastrointestinal tract using monocular images that often lack texture, while also remembering lesions after they leave the camera's view so that a clinical report can be produced at the end. Existing VLA models mostly map visual appearance and short-term context directly to actions, which limits their geometric grounding and their ability to report on an entire episode. The paper's goal is a single policy that predicts navigation actions, structured reasoning, stenosis opening shape, and a final lesion report, and that is evaluated both on recorded episodes and on a physical 3-DoF endoscope in phantoms.

Key Contributions

  1. A 3D-aware reasoning VLA framework. StenoVLA-3D integrates point-map encoding into a Cosmos-Reason 2 backbone through learned geometry-gated fusion, adds a temporal state branch for traversal progress and persistent memory for lesion evidence, and uses a shared reasoning-and-action head together with dedicated heads for stenosis shape estimation and episode-level reporting.
  2. The EndoCausal dataset. A dataset of 400 phantom sequences (about 0.8 million frames at 20 fps) linking endoscopic observations with lesion annotations, navigation actions, reconstruction-control targets, and temporally grounded reasoning.
  3. A controlled evaluation of geometry and memory components. The paper compares DA3 against EndoDAC and VGGT as geometry backbones, ablates reasoning, temporal memory, persistent memory, and geometry fusion, and reports physical-robot success rates of 88.9% in esophagoscopy and 77.8% in colonoscopy, plus zero-shot tests under appearance and deformation shifts.

Main Findings

  • Recorded-episode accuracy: On 40 held-out recorded EndoCausal test episodes, StenoVLA-3D reaches 95.2% semantic accuracy and 83.4% action accuracy.
  • Physical task success: On the physical 3-DoF endoscope, it attains 88.9% success in esophageal phantoms and 77.8% in colonic phantoms, with 36 trials per procedure, giving an unweighted average of 86.3 across the four metrics.
  • Comparison with baselines: EndoVLA* scores 80.2 semantic, 67.3 action, 50.0% esophagoscopy, 55.6% colonoscopy (average 63.3); π0.5 scores 55.2 action, 33.3% esophagoscopy, and 22.2% colonoscopy (average 36.9) and has no semantic score. Relative to EndoVLA*, StenoVLA-3D improves by 15.0, 16.1, 38.9, and 22.2 percentage points on the four metrics.
  • Geometry backbone matters: Steno-DAC (EndoDAC instead of DA3) averages 73.4 and Steno-VGGT averages 73.7, versus 86.3 for StenoVLA-3D. Steno-DAC has a slightly higher action score (84.7 versus 83.4), but StenoVLA-3D is far better in esophagoscopy (88.9% versus 63.9% and 58.3%), which the authors read as DA3 geometry transferring more reliably to stenosis traversal.
  • Reasoning supervision is critical: Removing reasoning drops the average from 86.3% to 48.5%, action from 83.4% to 56.5%, and physical success to 47.2% (esophagoscopy) and 41.7% (colonoscopy).
  • Temporal memory matters: Without temporal memory, semantic falls to 72.3%, action to 63.1%, and the average to 51.2%, which the authors attribute to degraded navigation-state estimation and delayed DA3 activation.
  • Persistent memory and geometry fusion gate physical success: Removing persistent memory leaves step-level scores relatively high (88.0% semantic, 79.2% action) but produces 0.0% success in both procedures, because the episode report cannot retain lesions after they leave view. Removing geometry fusion similarly keeps 85.5% semantic and 78.3% action while collapsing both procedures to 0.0%.
  • Zero-shot robustness varies by shift: Under unseen domain shifts without fine-tuning, view shift is closest to in-domain performance (91.1% semantic, 77.8% action, 83.3% esophagoscopy, 72.2% colonoscopy, average 81.1), followed by reflection (90.7% semantic, 81.0% action, average 79.1). Deformation reduces reasoning the most (66.1%) with an average of 65.8, and texture shift is weakest overall (77.0% semantic, 62.2% action, average 61.2, colonoscopy 50.0%).
  • Latency is the main bottleneck: The VLA requires 25.20 s to generate a decision and each asynchronous DA3 reconstruction job takes about 3.63 s, for 28.83 ± 0.65 s per decision overall. Steno-DAC takes 32.71 ± 0.25 s and Steno-VGGT 36.85 ± 0.78 s per decision; EndoVLA* is slower than StenoVLA-3D at 35.12 ± 0.57 s; π0.5 is fastest at 1.45 ± 0.41 s per inference.
  • Control schedule: The discrete policies emit one motion action every fourth frame on 20 fps recordings, corresponding to 5 Hz in video time; the 5 Hz figure is a command schedule, not wall-clock throughput.

Methodology in Plain English

Data collection and labeling. The team built a four-motor device that drives three endoscope degrees of freedom: yaw, pitch, and axial translation. One motor handles left-right steering, one handles up-down steering, and two counter-rotating motors jointly drive forward and backward motion. They recorded 400 sequences at 20 fps in anatomically structured esophageal and colonic phantoms, split into 320 training, 40 validation, and 40 test sequences, keeping all frames and derived variants from one original recording in a single split. Training-only augmentation produced roughly 2,200 additional sequences using brightness, contrast, colour, blur, horizontal and vertical flips, and rotations of up to 45 degrees; augmented samples have no point maps and are marked as geometry-unavailable. SAM 3 produced initial segmentation masks for stenoses, polyps, and ulcers, which were manually reviewed and corrected into convex-hull annotations. Manual event labels mark the usable-view boundary, stenosis confirmation, reconstruction start, stenosis entry, optional distal-end confirmation, reconstruction stop, and complete or incomplete termination. Motion targets are generated by a rule: move forward if the reviewed stenosis centroid is within 40 pixels of the image centre on both axes, otherwise take the 8-connected in-plane action that reduces that displacement, unless a recovery or termination event overrides it. Reasoning targets follow an observation-interpretation-decision template and cannot use future frames.

Model. The policy is initialized from Cosmos-Reason2-2B using the Qwen3-VL conditional-generation implementation. The pretrained backbone stays frozen while rank-16 LoRA adapters in the query, key, value, and output projections are trained. Geometry comes from the frozen DA3-Base model: point maps are packed as 4×16×112×112 tensors, encoded by a frozen 3D convolutional encoder into a 256-dimensional embedding, projected into the backbone's hidden size, and injected as a gated residual on the final-layer token representations rather than as extra input tokens. The gate is computed from the first backbone token and the projected geometry, and geometry is randomly omitted with probability 0.5 during training, in which case the opening-shape target becomes "not observable."

Memory and heads. A temporal memory averages image-token features and combines them with the final prompt token into a 512-dimensional feature, which updates a GRU state. Persistent memory keeps one 512-dimensional slot per lesion class (polyp, ulcer, stenosis) plus accumulated presence scores; a write gate based on current lesion evidence and the previous slot state controls how much each slot is updated, and presence is updated with a max operation so evidence survives after the lesion leaves view. A linear head predicts one of five opening-shape classes (circular, elliptical, slit-like, crescent, irregular) from the geometry embedding, and the reported shape is the last predicted class in that set; if none exists, the output is "not observable." At episode end, a report network takes the final GRU state, the three flattened memory slots, and the presence scores (a 2051-dimensional vector) and predicts polyp/ulcer presence and stenosis presence with separate heads, thresholded at 0.5 and inserted into a fixed report template.

Training. Training has two stages. Stage 1 optimizes LoRA adapters, geometry projection and gating, the memory projector, the GRU, persistent memory, lesion heads, and the report network with a combined loss over language modeling, per-step lesion presence, memory writes, episode report, and shape (shape only on geometry-active steps). Stage 2 continues from the Stage 1 checkpoint to refine reconstruction control, keeping reconstruction-transition frames, feeding the preceding controller state as input, and up-weighting motion-action tokens, activation/deactivation tokens, and no-change tokens. Stage 1 runs three epochs and Stage 2 one epoch, using AdamW with learning rates of 5e-6 for LoRA and 5e-5 for other modules, weight decay 0.01, and gradient clipping at norm 1.0, on an NVIDIA RTX A6000 GPU.

Inference. Decisions use only current and past images, the task instruction, the executed reconstruction state, and any completed geometry; ground-truth reasoning, navigation labels, and reconstruction events are withheld. A second forward pass over the prompt updates memory and the report heads. The reconstruction state is switched by the parsed navigation state, not by the auxiliary reconstruction command: ON for "prepare stenosis entry" and "traverse stenosis," OFF for "confirm stenosis end," "completed," and "terminated," otherwise unchanged. DA3 runs asynchronously, only completed batches from the active interval are consumed, and pending work is cancelled at episode end. Decoding is greedy with at most 192 new tokens.

Why This Matters

Research impact. The paper separates three capabilities that VLA work often conflates: explicit 3D geometric grounding, dual-timescale memory (short-term state plus persistent lesion evidence), and structured reasoning that is generated jointly with actions. Its ablation results are notable because step-level open-loop accuracy stays high while physical task success collapses to 0.0% when persistent memory or geometry fusion is removed, which argues that open-loop action matching is a poor proxy for procedural competence in this setting. The EndoCausal dataset and the controlled geometry-backbone comparison (DA3 versus EndoDAC versus VGGT) give the community reusable evaluation scaffolding.

Real-world applications.

  • Screening and surveillance colonoscopy, where the scope must pass through a narrowed lumen while keeping polyps and ulcers documented even after they leave view.
  • Evaluation of esophageal strictures, where the ASGE guidance cited in the paper calls for assessing stricture location, length, diameter, and etiology before treatment.
  • Automated or semi-automated procedure documentation, since the persistent memory produces an episode-level report of lesion types, stenosis presence, and opening shape.
  • Training and rehearsal in phantoms, where policies can be stress-tested under texture, viewpoint, reflection, and deformation shifts before any clinical exposure.

Industry relevance. The work is relevant to endoscope and surgical-robot manufacturers interested in higher-level autonomy, to developers of medical VLA foundation models, and to groups building clinical documentation pipelines, because the same memory that drives navigation also produces the report. The reported latency of about 28.83 s per decision makes clear that current general-purpose VLA inference is far from real-time control, which frames the near-term industrial use case as decision support or supervisory autonomy rather than continuous teleoperation replacement.

Future Directions

  • Reducing inference latency. The authors list quantization, KV caching, shorter outputs, and hardware-aware optimization as next steps; at 25.20 s per VLA decision, generation is the dominant cost and blocks continuous low-level control.
  • Moving beyond phantoms. Validation is phantom-only, so ex vivo tissue, animal, and ultimately clinical evaluation remain open, along with the tissue-contact safety concerns the paper raises.
  • Calibrated metric geometry. Opening shape is a qualitative class among circular, elliptical, slit-like, crescent, and irregular, not a calibrated measurement; the authors call for calibrated stenosis-length and lumen-diameter estimates.
  • Closing the offline-online geometry gap. Training uses jointly reconstructed offline point maps while inference uses causal online geometry estimated asynchronously; the authors identify this mismatch and propose causal-window retraining as a remedy.

Target Audience

Robotics and robot-learning researchers working on VLA architectures, memory, and 3D grounding; medical-robotics groups developing autonomous endoscopy and surgical assistants; clinicians and clinical engineers interested in how navigation policies might also generate procedure reports; and dataset or benchmark builders who need a controlled phantom testbed with lesion annotations, event labels, and reconstruction-control targets. Readers without background in VLA fine-tuning or point-map reconstruction will find the details dense, but the ablation and physical-trial results are legible without that background.

Authors’ abstract

Autonomous endoscopic navigation requires the policy model to predict actions from texture-poor monocular observations, make safe control decisions, and retain evidence of lesions after they leave the field of view. Existing vision-language-action (VLA) models primarily rely on visual appearance and short-term context, limiting geometric grounding and episode-level reporting. We introduce StenoVLA-3D, a 3D-aware VLA framework for navigating through stenotic regions. We…

The full abstract on arXiv
Read the original paper

Related papers